Cargando…
Magnon Confinement in an All-on-Chip YIG Cavity Resonator Using Hybrid YIG/Py Magnon Barriers
[Image: see text] Confining magnons in cavities can introduce new functionalities to magnonic devices, enabling future magnonic structures to emulate the established photonic and electronic components. As a proof-of-concept, we report magnon confinement in a lithographically defined all-on-chip YIG...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2023
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10603800/ https://www.ncbi.nlm.nih.gov/pubmed/37819876 http://dx.doi.org/10.1021/acs.nanolett.3c02388 |
_version_ | 1785126682853638144 |
---|---|
author | Santos, Obed Alves van Wees, Bart J. |
author_facet | Santos, Obed Alves van Wees, Bart J. |
author_sort | Santos, Obed Alves |
collection | PubMed |
description | [Image: see text] Confining magnons in cavities can introduce new functionalities to magnonic devices, enabling future magnonic structures to emulate the established photonic and electronic components. As a proof-of-concept, we report magnon confinement in a lithographically defined all-on-chip YIG cavity created between two YIG/Permalloy bilayers. We take advantage of the modified magnetic properties of the covered/uncovered YIG film to define on-chip distinct regions with boundaries capable of confining magnons. We confirm this by measuring multiple spin-pumping voltage peaks in a 400 nm wide platinum strip placed along the center of the cavity. These peaks coincide with multiple spin-wave resonance modes calculated for a YIG slab with the corresponding geometry. The fabrication of micrometer-sized YIG cavities following this technique represents a new approach to control coherent magnons, while the spin-pumping voltage in a nanometer-sized Pt strip demonstrates to be a noninvasive local detector of the magnon resonance intensity. |
format | Online Article Text |
id | pubmed-10603800 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-106038002023-10-28 Magnon Confinement in an All-on-Chip YIG Cavity Resonator Using Hybrid YIG/Py Magnon Barriers Santos, Obed Alves van Wees, Bart J. Nano Lett [Image: see text] Confining magnons in cavities can introduce new functionalities to magnonic devices, enabling future magnonic structures to emulate the established photonic and electronic components. As a proof-of-concept, we report magnon confinement in a lithographically defined all-on-chip YIG cavity created between two YIG/Permalloy bilayers. We take advantage of the modified magnetic properties of the covered/uncovered YIG film to define on-chip distinct regions with boundaries capable of confining magnons. We confirm this by measuring multiple spin-pumping voltage peaks in a 400 nm wide platinum strip placed along the center of the cavity. These peaks coincide with multiple spin-wave resonance modes calculated for a YIG slab with the corresponding geometry. The fabrication of micrometer-sized YIG cavities following this technique represents a new approach to control coherent magnons, while the spin-pumping voltage in a nanometer-sized Pt strip demonstrates to be a noninvasive local detector of the magnon resonance intensity. American Chemical Society 2023-10-11 /pmc/articles/PMC10603800/ /pubmed/37819876 http://dx.doi.org/10.1021/acs.nanolett.3c02388 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Santos, Obed Alves van Wees, Bart J. Magnon Confinement in an All-on-Chip YIG Cavity Resonator Using Hybrid YIG/Py Magnon Barriers |
title | Magnon Confinement
in an All-on-Chip YIG Cavity Resonator
Using Hybrid YIG/Py Magnon Barriers |
title_full | Magnon Confinement
in an All-on-Chip YIG Cavity Resonator
Using Hybrid YIG/Py Magnon Barriers |
title_fullStr | Magnon Confinement
in an All-on-Chip YIG Cavity Resonator
Using Hybrid YIG/Py Magnon Barriers |
title_full_unstemmed | Magnon Confinement
in an All-on-Chip YIG Cavity Resonator
Using Hybrid YIG/Py Magnon Barriers |
title_short | Magnon Confinement
in an All-on-Chip YIG Cavity Resonator
Using Hybrid YIG/Py Magnon Barriers |
title_sort | magnon confinement
in an all-on-chip yig cavity resonator
using hybrid yig/py magnon barriers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10603800/ https://www.ncbi.nlm.nih.gov/pubmed/37819876 http://dx.doi.org/10.1021/acs.nanolett.3c02388 |
work_keys_str_mv | AT santosobedalves magnonconfinementinanallonchipyigcavityresonatorusinghybridyigpymagnonbarriers AT vanweesbartj magnonconfinementinanallonchipyigcavityresonatorusinghybridyigpymagnonbarriers |