Cargando…

Development of a Three-Dimensional Carotid Ultrasound Image Segmentation Workflow for Improved Efficiency, Reproducibility and Accuracy in Measuring Vessel Wall and Plaque Volume and Thickness

Automated segmentation of carotid lumen-intima boundary (LIB) and media-adventitia boundary (MAB) by deep convolutional neural networks (CNN) from three-dimensional ultrasound (3DUS) images has made assessment and monitoring of carotid atherosclerosis more efficient than manual segmentation. However...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Yuan, Jiang, Mingjie, Chan, Wai Sum, Chiu, Bernard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10603859/
https://www.ncbi.nlm.nih.gov/pubmed/37892947
http://dx.doi.org/10.3390/bioengineering10101217
_version_ 1785126696351956992
author Zhao, Yuan
Jiang, Mingjie
Chan, Wai Sum
Chiu, Bernard
author_facet Zhao, Yuan
Jiang, Mingjie
Chan, Wai Sum
Chiu, Bernard
author_sort Zhao, Yuan
collection PubMed
description Automated segmentation of carotid lumen-intima boundary (LIB) and media-adventitia boundary (MAB) by deep convolutional neural networks (CNN) from three-dimensional ultrasound (3DUS) images has made assessment and monitoring of carotid atherosclerosis more efficient than manual segmentation. However, training of CNN still requires manual segmentation of LIB and MAB. Therefore, there is a need to improve the efficiency of manual segmentation and develop strategies to improve segmentation accuracy by the CNN for serial monitoring of carotid atherosclerosis. One strategy to reduce segmentation time is to increase the interslice distance (ISD) between segmented axial slices of a 3DUS image while maintaining the segmentation reliability. We, for the first time, investigated the effect of ISD on the reproducibility of MAB and LIB segmentations. The intra-observer reproducibility of LIB and MAB segmentations at ISDs of 1 mm and 2 mm was not statistically significantly different, whereas the reproducibility at ISD = 3 mm was statistically lower. Therefore, we conclude that segmentation with an ISD of 2 mm provides sufficient reliability for CNN training. We further proposed training the CNN by the baseline images of the entire cohort of patients for automatic segmentation of the follow-up images acquired for the same cohort. We validated that segmentation with this time-based partitioning approach is more accurate than that produced by patient-based partitioning, especially at the carotid bifurcation. This study forms the basis for an efficient, reproducible, and accurate 3DUS workflow for serial monitoring of carotid atherosclerosis useful in risk stratification of cardiovascular events and in evaluating the efficacy of new treatments.
format Online
Article
Text
id pubmed-10603859
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106038592023-10-28 Development of a Three-Dimensional Carotid Ultrasound Image Segmentation Workflow for Improved Efficiency, Reproducibility and Accuracy in Measuring Vessel Wall and Plaque Volume and Thickness Zhao, Yuan Jiang, Mingjie Chan, Wai Sum Chiu, Bernard Bioengineering (Basel) Article Automated segmentation of carotid lumen-intima boundary (LIB) and media-adventitia boundary (MAB) by deep convolutional neural networks (CNN) from three-dimensional ultrasound (3DUS) images has made assessment and monitoring of carotid atherosclerosis more efficient than manual segmentation. However, training of CNN still requires manual segmentation of LIB and MAB. Therefore, there is a need to improve the efficiency of manual segmentation and develop strategies to improve segmentation accuracy by the CNN for serial monitoring of carotid atherosclerosis. One strategy to reduce segmentation time is to increase the interslice distance (ISD) between segmented axial slices of a 3DUS image while maintaining the segmentation reliability. We, for the first time, investigated the effect of ISD on the reproducibility of MAB and LIB segmentations. The intra-observer reproducibility of LIB and MAB segmentations at ISDs of 1 mm and 2 mm was not statistically significantly different, whereas the reproducibility at ISD = 3 mm was statistically lower. Therefore, we conclude that segmentation with an ISD of 2 mm provides sufficient reliability for CNN training. We further proposed training the CNN by the baseline images of the entire cohort of patients for automatic segmentation of the follow-up images acquired for the same cohort. We validated that segmentation with this time-based partitioning approach is more accurate than that produced by patient-based partitioning, especially at the carotid bifurcation. This study forms the basis for an efficient, reproducible, and accurate 3DUS workflow for serial monitoring of carotid atherosclerosis useful in risk stratification of cardiovascular events and in evaluating the efficacy of new treatments. MDPI 2023-10-18 /pmc/articles/PMC10603859/ /pubmed/37892947 http://dx.doi.org/10.3390/bioengineering10101217 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhao, Yuan
Jiang, Mingjie
Chan, Wai Sum
Chiu, Bernard
Development of a Three-Dimensional Carotid Ultrasound Image Segmentation Workflow for Improved Efficiency, Reproducibility and Accuracy in Measuring Vessel Wall and Plaque Volume and Thickness
title Development of a Three-Dimensional Carotid Ultrasound Image Segmentation Workflow for Improved Efficiency, Reproducibility and Accuracy in Measuring Vessel Wall and Plaque Volume and Thickness
title_full Development of a Three-Dimensional Carotid Ultrasound Image Segmentation Workflow for Improved Efficiency, Reproducibility and Accuracy in Measuring Vessel Wall and Plaque Volume and Thickness
title_fullStr Development of a Three-Dimensional Carotid Ultrasound Image Segmentation Workflow for Improved Efficiency, Reproducibility and Accuracy in Measuring Vessel Wall and Plaque Volume and Thickness
title_full_unstemmed Development of a Three-Dimensional Carotid Ultrasound Image Segmentation Workflow for Improved Efficiency, Reproducibility and Accuracy in Measuring Vessel Wall and Plaque Volume and Thickness
title_short Development of a Three-Dimensional Carotid Ultrasound Image Segmentation Workflow for Improved Efficiency, Reproducibility and Accuracy in Measuring Vessel Wall and Plaque Volume and Thickness
title_sort development of a three-dimensional carotid ultrasound image segmentation workflow for improved efficiency, reproducibility and accuracy in measuring vessel wall and plaque volume and thickness
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10603859/
https://www.ncbi.nlm.nih.gov/pubmed/37892947
http://dx.doi.org/10.3390/bioengineering10101217
work_keys_str_mv AT zhaoyuan developmentofathreedimensionalcarotidultrasoundimagesegmentationworkflowforimprovedefficiencyreproducibilityandaccuracyinmeasuringvesselwallandplaquevolumeandthickness
AT jiangmingjie developmentofathreedimensionalcarotidultrasoundimagesegmentationworkflowforimprovedefficiencyreproducibilityandaccuracyinmeasuringvesselwallandplaquevolumeandthickness
AT chanwaisum developmentofathreedimensionalcarotidultrasoundimagesegmentationworkflowforimprovedefficiencyreproducibilityandaccuracyinmeasuringvesselwallandplaquevolumeandthickness
AT chiubernard developmentofathreedimensionalcarotidultrasoundimagesegmentationworkflowforimprovedefficiencyreproducibilityandaccuracyinmeasuringvesselwallandplaquevolumeandthickness