Cargando…

Non-contrast low-dose CT can be used for volumetry of ADPKD

BACKGROUND: Kidney volume provides important information for the diagnosis and prognosis of autosomal dominant polycystic kidney disease (ADPKD), as well as for the evaluation of the effects of drugs such as tolvaptan. Non-contrast computed tomography (CT) is commonly used for volumetry, and this st...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoo, Jaeyeong, Kim, Jin up, Kim, Jisu, Jeon, Sohyun, Song, Young-jin, Choi, Kwang-ho, Kim, Seok-hyung, Yoon, Jong-woo, Kim, Hyunsuk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10604523/
https://www.ncbi.nlm.nih.gov/pubmed/37884882
http://dx.doi.org/10.1186/s12882-023-03359-z
Descripción
Sumario:BACKGROUND: Kidney volume provides important information for the diagnosis and prognosis of autosomal dominant polycystic kidney disease (ADPKD), as well as for the evaluation of the effects of drugs such as tolvaptan. Non-contrast computed tomography (CT) is commonly used for volumetry, and this study examined the correspondence and correlation of kidney volume measured by standard-dose or low-dose CT. METHODS: Axial standard-dose and low-dose CT images with 1-mm slices were obtained from 24 ADPKD patients. The kidney was segmented in the Synapse 3D software and the kidney volume was calculated using stereology. The kidney volume was compared between the two sets of images using R(2), Bland-Altman plots, coefficient of variation, and intra-class correlation coefficients (ICCs). RESULTS: The mean age of the 24 patients was 48.4 ± 10.9 years, and 45.8% were men (n = 11). The mean total kidney volume on standard-dose CT was 1501 ± 838.2 mL. The R(2) of volume between standard-dose and low-dose CT was 0.995. In the Bland-Altman plot, except for one case with a large kidney volume, the two measurements were consistent, and the coefficient of variation and ICC were also good (0.02, 0.998). The CT radiation dose (dose-length product) was 229 ± 68 mGy·cm for standard-dose CT and 50 ± 19 mGy·cm for low-dose CT. A comparable volume was obtained with 20% of the radiation dose of standard-dose CT. CONCLUSIONS: Standard-dose and low-dose CT showed comparable kidney volume in ADPKD. Therefore, low-dose CT can substitute for ADPKD volumetry while minimizing radiation exposure. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12882-023-03359-z.