Treatment of Severe Pulmonary Regurgitation in Enlarged Native Right Ventricular Outflow Tracts: Transcatheter Pulmonary Valve Replacement with Three-Dimensional Printing Guidance
Background: Severe pulmonary regurgitation (PR) often occurs following a transannular patch repair of tetralogy of Fallot, resulting in an enlarged native right ventricular outflow tract (nRVOT) with varying shapes. Methods: We conducted a single-center study with eight patients having severe PR and...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10604601/ https://www.ncbi.nlm.nih.gov/pubmed/37892867 http://dx.doi.org/10.3390/bioengineering10101136 |
Sumario: | Background: Severe pulmonary regurgitation (PR) often occurs following a transannular patch repair of tetralogy of Fallot, resulting in an enlarged native right ventricular outflow tract (nRVOT) with varying shapes. Methods: We conducted a single-center study with eight patients having severe PR and enlarged nRVOT (diameters ≥ 29 mm). Transcatheter pulmonary valve replacement (TPVR) was performed using the self-expanding PT-Valve. Preoperative evaluation included echocardiography, computed tomography, and magnetic resonance imaging. A 3D-printed model of the nRVOT was used for preoperative assessment. Follow-up data were collected in 1-year follow-up. Results: PT-Valve was successfully implanted in all patients, resulting in immediate improvement of severe PR. Pulmonary artery diastolic pressure increased significantly (p < 0.001). No deaths or coronary compression occurred during the procedure. Over a 1-year follow-up, no stent displacement or fracture occurred. Only two patients had trace paravalvular leaks. Magnetic resonance imaging revealed a reversal of right ventricular remodeling, with a significant reduction in right ventricular end-diastolic volume index (p < 0.001) and improved right ventricular ejection fraction (p < 0.001). All patients achieved primary endpoints. Conclusion: 3D printing-guided PT-Valve implantation in enlarged nRVOT for severe PR is safe and effective, expanding TPVR indications and offering potential treatment for a broader patient population. |
---|