Cargando…

Comparative Evaluation of Metallic and Biodegradable Suture Anchors in Arthroscopic Repair of Anterior Talofibular Ligament Injury: A Short-term Study on Clinical and Functional Outcomes

BACKGROUND: With the development of arthroscopy and suture anchor, the modified Broström technique has made remarkable progress. However, it is unclear which material is most suitable for treating anterior talofibular ligament injury (ATFL). This study evaluated the short-term efficacy of 2 suture a...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Lei, Tang, Xiaogao, You, Guixuan, Chen, Xueyi, Yang, Siyi, Shi, Houyin, Wang, Guoyou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10605517/
https://www.ncbi.nlm.nih.gov/pubmed/37867316
http://dx.doi.org/10.12659/MSM.939830
_version_ 1785127093307179008
author Zhang, Lei
Tang, Xiaogao
You, Guixuan
Chen, Xueyi
Yang, Siyi
Shi, Houyin
Wang, Guoyou
author_facet Zhang, Lei
Tang, Xiaogao
You, Guixuan
Chen, Xueyi
Yang, Siyi
Shi, Houyin
Wang, Guoyou
author_sort Zhang, Lei
collection PubMed
description BACKGROUND: With the development of arthroscopy and suture anchor, the modified Broström technique has made remarkable progress. However, it is unclear which material is most suitable for treating anterior talofibular ligament injury (ATFL). This study evaluated the short-term efficacy of 2 suture anchors (metal vs biodegradable materials) in arthroscopic ATFL repair. MATERIAL/METHODS: From January 2018 to December 2019, 82 patients with ankle disorders (51 men and 31 women) with ATFL injury received arthroscopic repair with suture anchor through the Broström-Gould procedure. The mean age was 38.70±9.35 years (range, 18–54 years). Each patient was followed up. American Orthopedic Foot and Ankle Society score (AOFAS), Karlsson Ankle Functional Score (KAFS), and the Visual Analogue Scale (VAS) were used to evaluate functional status and pain. RESULTS: All patients were followed up for 21.21±2.19 months (range, 18–25 months). No complications were found either group. Preoperative clinical and functional scores in both groups had no significant difference (P>0.05). The functional score increased significantly in both groups (P<0.001). At the last follow-up, the mean AOFAS score was 93.00 (90.00, 96.00) in the Biodegradable group and 93.50 (91.00, 96.00) in the Metallic group (P=0.31). The mean KAFS score was 91.50 (85.00, 95.00) in the Biodegradable group and 93.00 (90.00, 95.50) in the Metallic group (P=0.10); the mean VAS score was 1.50 (1.00, 1.80) in the Biodegradable group and 1.30 (0.98, 1.70) in the Metallic group (P=0.22). CONCLUSIONS: Arthroscopic repair of ATFL injury with suture anchors can improve the prognosis of CAI. There were no statistically significant differences in clinical and functional outcomes with metal or biodegradable suture anchors at short-term follow-up.
format Online
Article
Text
id pubmed-10605517
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-106055172023-10-28 Comparative Evaluation of Metallic and Biodegradable Suture Anchors in Arthroscopic Repair of Anterior Talofibular Ligament Injury: A Short-term Study on Clinical and Functional Outcomes Zhang, Lei Tang, Xiaogao You, Guixuan Chen, Xueyi Yang, Siyi Shi, Houyin Wang, Guoyou Med Sci Monit Clinical Research BACKGROUND: With the development of arthroscopy and suture anchor, the modified Broström technique has made remarkable progress. However, it is unclear which material is most suitable for treating anterior talofibular ligament injury (ATFL). This study evaluated the short-term efficacy of 2 suture anchors (metal vs biodegradable materials) in arthroscopic ATFL repair. MATERIAL/METHODS: From January 2018 to December 2019, 82 patients with ankle disorders (51 men and 31 women) with ATFL injury received arthroscopic repair with suture anchor through the Broström-Gould procedure. The mean age was 38.70±9.35 years (range, 18–54 years). Each patient was followed up. American Orthopedic Foot and Ankle Society score (AOFAS), Karlsson Ankle Functional Score (KAFS), and the Visual Analogue Scale (VAS) were used to evaluate functional status and pain. RESULTS: All patients were followed up for 21.21±2.19 months (range, 18–25 months). No complications were found either group. Preoperative clinical and functional scores in both groups had no significant difference (P>0.05). The functional score increased significantly in both groups (P<0.001). At the last follow-up, the mean AOFAS score was 93.00 (90.00, 96.00) in the Biodegradable group and 93.50 (91.00, 96.00) in the Metallic group (P=0.31). The mean KAFS score was 91.50 (85.00, 95.00) in the Biodegradable group and 93.00 (90.00, 95.50) in the Metallic group (P=0.10); the mean VAS score was 1.50 (1.00, 1.80) in the Biodegradable group and 1.30 (0.98, 1.70) in the Metallic group (P=0.22). CONCLUSIONS: Arthroscopic repair of ATFL injury with suture anchors can improve the prognosis of CAI. There were no statistically significant differences in clinical and functional outcomes with metal or biodegradable suture anchors at short-term follow-up. International Scientific Literature, Inc. 2023-10-23 /pmc/articles/PMC10605517/ /pubmed/37867316 http://dx.doi.org/10.12659/MSM.939830 Text en © Med Sci Monit, 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Zhang, Lei
Tang, Xiaogao
You, Guixuan
Chen, Xueyi
Yang, Siyi
Shi, Houyin
Wang, Guoyou
Comparative Evaluation of Metallic and Biodegradable Suture Anchors in Arthroscopic Repair of Anterior Talofibular Ligament Injury: A Short-term Study on Clinical and Functional Outcomes
title Comparative Evaluation of Metallic and Biodegradable Suture Anchors in Arthroscopic Repair of Anterior Talofibular Ligament Injury: A Short-term Study on Clinical and Functional Outcomes
title_full Comparative Evaluation of Metallic and Biodegradable Suture Anchors in Arthroscopic Repair of Anterior Talofibular Ligament Injury: A Short-term Study on Clinical and Functional Outcomes
title_fullStr Comparative Evaluation of Metallic and Biodegradable Suture Anchors in Arthroscopic Repair of Anterior Talofibular Ligament Injury: A Short-term Study on Clinical and Functional Outcomes
title_full_unstemmed Comparative Evaluation of Metallic and Biodegradable Suture Anchors in Arthroscopic Repair of Anterior Talofibular Ligament Injury: A Short-term Study on Clinical and Functional Outcomes
title_short Comparative Evaluation of Metallic and Biodegradable Suture Anchors in Arthroscopic Repair of Anterior Talofibular Ligament Injury: A Short-term Study on Clinical and Functional Outcomes
title_sort comparative evaluation of metallic and biodegradable suture anchors in arthroscopic repair of anterior talofibular ligament injury: a short-term study on clinical and functional outcomes
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10605517/
https://www.ncbi.nlm.nih.gov/pubmed/37867316
http://dx.doi.org/10.12659/MSM.939830
work_keys_str_mv AT zhanglei comparativeevaluationofmetallicandbiodegradablesutureanchorsinarthroscopicrepairofanteriortalofibularligamentinjuryashorttermstudyonclinicalandfunctionaloutcomes
AT tangxiaogao comparativeevaluationofmetallicandbiodegradablesutureanchorsinarthroscopicrepairofanteriortalofibularligamentinjuryashorttermstudyonclinicalandfunctionaloutcomes
AT youguixuan comparativeevaluationofmetallicandbiodegradablesutureanchorsinarthroscopicrepairofanteriortalofibularligamentinjuryashorttermstudyonclinicalandfunctionaloutcomes
AT chenxueyi comparativeevaluationofmetallicandbiodegradablesutureanchorsinarthroscopicrepairofanteriortalofibularligamentinjuryashorttermstudyonclinicalandfunctionaloutcomes
AT yangsiyi comparativeevaluationofmetallicandbiodegradablesutureanchorsinarthroscopicrepairofanteriortalofibularligamentinjuryashorttermstudyonclinicalandfunctionaloutcomes
AT shihouyin comparativeevaluationofmetallicandbiodegradablesutureanchorsinarthroscopicrepairofanteriortalofibularligamentinjuryashorttermstudyonclinicalandfunctionaloutcomes
AT wangguoyou comparativeevaluationofmetallicandbiodegradablesutureanchorsinarthroscopicrepairofanteriortalofibularligamentinjuryashorttermstudyonclinicalandfunctionaloutcomes