Cargando…

Unveiling the Accuracy of Ultrasonographic Assessment of Thyroid Volume: A Comparative Analysis of Ultrasonographic Measurements and Specimen Volumes

In endocrine surgery, a precise ultrasonographic measurement of thyroid volume is crucial. However, there is limited comparative research between ultrasonographic and specimen volumes, which has left this issue open to debate. This study aims to assess the accuracy of recommended formulas for ultras...

Descripción completa

Detalles Bibliográficos
Autores principales: Konca, Can, Elhan, Atilla Halil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10607290/
https://www.ncbi.nlm.nih.gov/pubmed/37892758
http://dx.doi.org/10.3390/jcm12206619
_version_ 1785127510981214208
author Konca, Can
Elhan, Atilla Halil
author_facet Konca, Can
Elhan, Atilla Halil
author_sort Konca, Can
collection PubMed
description In endocrine surgery, a precise ultrasonographic measurement of thyroid volume is crucial. However, there is limited comparative research between ultrasonographic and specimen volumes, which has left this issue open to debate. This study aims to assess the accuracy of recommended formulas for ultrasonographic thyroid volume measurement by comparing them to specimen volumes and analyzing the influencing variables. From the data of 120 eligible patients, different formulas, including ultrasonographic thyroid volume (US-TV) based on the ellipsoid formula, lower correction factor thyroid volume (LCF-TV), and calculated ultrasonographic (derived formula) thyroid volume (CU-TV), were used to estimate the thyroid volume based on measurements taken prior to surgery. These measurements were compared with the intraoperative specimen volume (IO-TV) derived using Archimedes’ principle. According to our findings, the mean values for US-TV and LCF-TV were significantly lower, whereas CU-TV was higher than IO-TV. Deviations were more significant in patients who had surgery for benign indications or compressive symptoms and in those with suppressed thyroid-stimulating hormone levels. Although the ellipsoid formula tends to underestimate the actual thyroid volume, it remains the most accurate method for measuring ultrasonographic thyroid volume. The deviation is greater for larger volumes.
format Online
Article
Text
id pubmed-10607290
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106072902023-10-28 Unveiling the Accuracy of Ultrasonographic Assessment of Thyroid Volume: A Comparative Analysis of Ultrasonographic Measurements and Specimen Volumes Konca, Can Elhan, Atilla Halil J Clin Med Article In endocrine surgery, a precise ultrasonographic measurement of thyroid volume is crucial. However, there is limited comparative research between ultrasonographic and specimen volumes, which has left this issue open to debate. This study aims to assess the accuracy of recommended formulas for ultrasonographic thyroid volume measurement by comparing them to specimen volumes and analyzing the influencing variables. From the data of 120 eligible patients, different formulas, including ultrasonographic thyroid volume (US-TV) based on the ellipsoid formula, lower correction factor thyroid volume (LCF-TV), and calculated ultrasonographic (derived formula) thyroid volume (CU-TV), were used to estimate the thyroid volume based on measurements taken prior to surgery. These measurements were compared with the intraoperative specimen volume (IO-TV) derived using Archimedes’ principle. According to our findings, the mean values for US-TV and LCF-TV were significantly lower, whereas CU-TV was higher than IO-TV. Deviations were more significant in patients who had surgery for benign indications or compressive symptoms and in those with suppressed thyroid-stimulating hormone levels. Although the ellipsoid formula tends to underestimate the actual thyroid volume, it remains the most accurate method for measuring ultrasonographic thyroid volume. The deviation is greater for larger volumes. MDPI 2023-10-19 /pmc/articles/PMC10607290/ /pubmed/37892758 http://dx.doi.org/10.3390/jcm12206619 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Konca, Can
Elhan, Atilla Halil
Unveiling the Accuracy of Ultrasonographic Assessment of Thyroid Volume: A Comparative Analysis of Ultrasonographic Measurements and Specimen Volumes
title Unveiling the Accuracy of Ultrasonographic Assessment of Thyroid Volume: A Comparative Analysis of Ultrasonographic Measurements and Specimen Volumes
title_full Unveiling the Accuracy of Ultrasonographic Assessment of Thyroid Volume: A Comparative Analysis of Ultrasonographic Measurements and Specimen Volumes
title_fullStr Unveiling the Accuracy of Ultrasonographic Assessment of Thyroid Volume: A Comparative Analysis of Ultrasonographic Measurements and Specimen Volumes
title_full_unstemmed Unveiling the Accuracy of Ultrasonographic Assessment of Thyroid Volume: A Comparative Analysis of Ultrasonographic Measurements and Specimen Volumes
title_short Unveiling the Accuracy of Ultrasonographic Assessment of Thyroid Volume: A Comparative Analysis of Ultrasonographic Measurements and Specimen Volumes
title_sort unveiling the accuracy of ultrasonographic assessment of thyroid volume: a comparative analysis of ultrasonographic measurements and specimen volumes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10607290/
https://www.ncbi.nlm.nih.gov/pubmed/37892758
http://dx.doi.org/10.3390/jcm12206619
work_keys_str_mv AT koncacan unveilingtheaccuracyofultrasonographicassessmentofthyroidvolumeacomparativeanalysisofultrasonographicmeasurementsandspecimenvolumes
AT elhanatillahalil unveilingtheaccuracyofultrasonographicassessmentofthyroidvolumeacomparativeanalysisofultrasonographicmeasurementsandspecimenvolumes