Cargando…
Safety and Efficacy of Uninterrupted Oral Anticoagulation in Patients Undergoing Catheter Ablation for Atrial Fibrillation with Different Techniques
Background. The safety and efficacy of an uninterrupted direct anticoagulation (DOAC) strategy during catheter ablation (CA) for atrial fibrillation (AF) has not been fully investigated with different ablation techniques. Methods. We evaluated consecutive AF patients undergoing catheter ablation wit...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10607349/ https://www.ncbi.nlm.nih.gov/pubmed/37892671 http://dx.doi.org/10.3390/jcm12206533 |
_version_ | 1785127525320491008 |
---|---|
author | Schiavone, Marco Gasperetti, Alessio Filtz, Annalisa Vantaggiato, Gaia Gobbi, Cecilia Tondo, Claudio Forleo, Giovanni Battista |
author_facet | Schiavone, Marco Gasperetti, Alessio Filtz, Annalisa Vantaggiato, Gaia Gobbi, Cecilia Tondo, Claudio Forleo, Giovanni Battista |
author_sort | Schiavone, Marco |
collection | PubMed |
description | Background. The safety and efficacy of an uninterrupted direct anticoagulation (DOAC) strategy during catheter ablation (CA) for atrial fibrillation (AF) has not been fully investigated with different ablation techniques. Methods. We evaluated consecutive AF patients undergoing catheter ablation with three different techniques. All patients were managed with an uninterrupted DOAC strategy. The primary endpoint was the rate of periprocedural thromboembolic and bleeding events. The secondary endpoints of the study were the rate of MACE and bleeding events at one-year follow-up. Results. In total, 162 patients were enrolled. Overall, 53 were female and the median age was 60 [55.5–69.5] years. The median CHA(2)DS(2)-VASc and HAS-BLED scores were 2 [1–4] and 2 [1–2], respectively. In total, 16 patients had a past stroke or TIA while 11 had a predisposition or a history of bleeding. The CA procedure was performed with different techniques: RF 43%, cryoballoon 37%, or laser–balloon 20%. Overall, 35.8% were on rivaroxaban, 20.4% were on edoxaban, 6.8% were on apixaban, and 3.7% were on dabigatran. All other patients were all naïve to DOACs; the first anticoagulant dose was given before the ablation procedure. As for periprocedural complications, we found three groin hematomas not requiring interventions, one ischemic stroke, and one systemic air embolism (the last two likely due to several catheter changes through the transeptal sheath). Five patients reached the secondary endpoints: one patient for a myocardial infarction while four patients experienced minor bleeding during 1-year follow-up. Conclusions. Our results corroborate the safety and the efficacy of uninterrupted DOAC strategy in patients undergoing CA for AF, regardless of the ablation technique. |
format | Online Article Text |
id | pubmed-10607349 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106073492023-10-28 Safety and Efficacy of Uninterrupted Oral Anticoagulation in Patients Undergoing Catheter Ablation for Atrial Fibrillation with Different Techniques Schiavone, Marco Gasperetti, Alessio Filtz, Annalisa Vantaggiato, Gaia Gobbi, Cecilia Tondo, Claudio Forleo, Giovanni Battista J Clin Med Article Background. The safety and efficacy of an uninterrupted direct anticoagulation (DOAC) strategy during catheter ablation (CA) for atrial fibrillation (AF) has not been fully investigated with different ablation techniques. Methods. We evaluated consecutive AF patients undergoing catheter ablation with three different techniques. All patients were managed with an uninterrupted DOAC strategy. The primary endpoint was the rate of periprocedural thromboembolic and bleeding events. The secondary endpoints of the study were the rate of MACE and bleeding events at one-year follow-up. Results. In total, 162 patients were enrolled. Overall, 53 were female and the median age was 60 [55.5–69.5] years. The median CHA(2)DS(2)-VASc and HAS-BLED scores were 2 [1–4] and 2 [1–2], respectively. In total, 16 patients had a past stroke or TIA while 11 had a predisposition or a history of bleeding. The CA procedure was performed with different techniques: RF 43%, cryoballoon 37%, or laser–balloon 20%. Overall, 35.8% were on rivaroxaban, 20.4% were on edoxaban, 6.8% were on apixaban, and 3.7% were on dabigatran. All other patients were all naïve to DOACs; the first anticoagulant dose was given before the ablation procedure. As for periprocedural complications, we found three groin hematomas not requiring interventions, one ischemic stroke, and one systemic air embolism (the last two likely due to several catheter changes through the transeptal sheath). Five patients reached the secondary endpoints: one patient for a myocardial infarction while four patients experienced minor bleeding during 1-year follow-up. Conclusions. Our results corroborate the safety and the efficacy of uninterrupted DOAC strategy in patients undergoing CA for AF, regardless of the ablation technique. MDPI 2023-10-15 /pmc/articles/PMC10607349/ /pubmed/37892671 http://dx.doi.org/10.3390/jcm12206533 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Schiavone, Marco Gasperetti, Alessio Filtz, Annalisa Vantaggiato, Gaia Gobbi, Cecilia Tondo, Claudio Forleo, Giovanni Battista Safety and Efficacy of Uninterrupted Oral Anticoagulation in Patients Undergoing Catheter Ablation for Atrial Fibrillation with Different Techniques |
title | Safety and Efficacy of Uninterrupted Oral Anticoagulation in Patients Undergoing Catheter Ablation for Atrial Fibrillation with Different Techniques |
title_full | Safety and Efficacy of Uninterrupted Oral Anticoagulation in Patients Undergoing Catheter Ablation for Atrial Fibrillation with Different Techniques |
title_fullStr | Safety and Efficacy of Uninterrupted Oral Anticoagulation in Patients Undergoing Catheter Ablation for Atrial Fibrillation with Different Techniques |
title_full_unstemmed | Safety and Efficacy of Uninterrupted Oral Anticoagulation in Patients Undergoing Catheter Ablation for Atrial Fibrillation with Different Techniques |
title_short | Safety and Efficacy of Uninterrupted Oral Anticoagulation in Patients Undergoing Catheter Ablation for Atrial Fibrillation with Different Techniques |
title_sort | safety and efficacy of uninterrupted oral anticoagulation in patients undergoing catheter ablation for atrial fibrillation with different techniques |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10607349/ https://www.ncbi.nlm.nih.gov/pubmed/37892671 http://dx.doi.org/10.3390/jcm12206533 |
work_keys_str_mv | AT schiavonemarco safetyandefficacyofuninterruptedoralanticoagulationinpatientsundergoingcatheterablationforatrialfibrillationwithdifferenttechniques AT gasperettialessio safetyandefficacyofuninterruptedoralanticoagulationinpatientsundergoingcatheterablationforatrialfibrillationwithdifferenttechniques AT filtzannalisa safetyandefficacyofuninterruptedoralanticoagulationinpatientsundergoingcatheterablationforatrialfibrillationwithdifferenttechniques AT vantaggiatogaia safetyandefficacyofuninterruptedoralanticoagulationinpatientsundergoingcatheterablationforatrialfibrillationwithdifferenttechniques AT gobbicecilia safetyandefficacyofuninterruptedoralanticoagulationinpatientsundergoingcatheterablationforatrialfibrillationwithdifferenttechniques AT tondoclaudio safetyandefficacyofuninterruptedoralanticoagulationinpatientsundergoingcatheterablationforatrialfibrillationwithdifferenttechniques AT forleogiovannibattista safetyandefficacyofuninterruptedoralanticoagulationinpatientsundergoingcatheterablationforatrialfibrillationwithdifferenttechniques |