Cargando…

Wear, Osteolysis, and Aseptic Loosening Following Total Hip Arthroplasty in Young Patients with Highly Cross-Linked Polyethylene: A Review of Studies with a Follow-Up of over 15 Years

Total hip arthroplasty (THA) has in recent years trended toward a younger, more physically demanding patient population. Mid- to long-term studies of all ages of THA patients using highly cross-linked polyethylene (HXLPE) have been favorable, but concerns about its long-term failure and wear-related...

Descripción completa

Detalles Bibliográficos
Autores principales: Deans, Christopher F., Buckner, Brandt C., Garvin, Kevin L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10607435/
https://www.ncbi.nlm.nih.gov/pubmed/37892754
http://dx.doi.org/10.3390/jcm12206615
_version_ 1785127540875067392
author Deans, Christopher F.
Buckner, Brandt C.
Garvin, Kevin L.
author_facet Deans, Christopher F.
Buckner, Brandt C.
Garvin, Kevin L.
author_sort Deans, Christopher F.
collection PubMed
description Total hip arthroplasty (THA) has in recent years trended toward a younger, more physically demanding patient population. Mid- to long-term studies of all ages of THA patients using highly cross-linked polyethylene (HXLPE) have been favorable, but concerns about its long-term failure and wear-related complications remain for young THA patients. In this narrative review, a search of the PubMed/MEDLINE and Cochrane databases was performed, and we identified six studies with a minimum 15-year follow-up of HXLPE with various femoral head materials. Wear-related revisions were exceedingly low for patients under the age of 55, with variable reports of non-clinically significant osteolysis. Higher activity levels, a larger femoral head size, and femoral head material were not associated with greater long-term wear rates. Young THA with metal or ceramic on HXLPE is exceedingly durable with favorable outcomes at follow-ups of over 15 years.
format Online
Article
Text
id pubmed-10607435
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106074352023-10-28 Wear, Osteolysis, and Aseptic Loosening Following Total Hip Arthroplasty in Young Patients with Highly Cross-Linked Polyethylene: A Review of Studies with a Follow-Up of over 15 Years Deans, Christopher F. Buckner, Brandt C. Garvin, Kevin L. J Clin Med Review Total hip arthroplasty (THA) has in recent years trended toward a younger, more physically demanding patient population. Mid- to long-term studies of all ages of THA patients using highly cross-linked polyethylene (HXLPE) have been favorable, but concerns about its long-term failure and wear-related complications remain for young THA patients. In this narrative review, a search of the PubMed/MEDLINE and Cochrane databases was performed, and we identified six studies with a minimum 15-year follow-up of HXLPE with various femoral head materials. Wear-related revisions were exceedingly low for patients under the age of 55, with variable reports of non-clinically significant osteolysis. Higher activity levels, a larger femoral head size, and femoral head material were not associated with greater long-term wear rates. Young THA with metal or ceramic on HXLPE is exceedingly durable with favorable outcomes at follow-ups of over 15 years. MDPI 2023-10-19 /pmc/articles/PMC10607435/ /pubmed/37892754 http://dx.doi.org/10.3390/jcm12206615 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Deans, Christopher F.
Buckner, Brandt C.
Garvin, Kevin L.
Wear, Osteolysis, and Aseptic Loosening Following Total Hip Arthroplasty in Young Patients with Highly Cross-Linked Polyethylene: A Review of Studies with a Follow-Up of over 15 Years
title Wear, Osteolysis, and Aseptic Loosening Following Total Hip Arthroplasty in Young Patients with Highly Cross-Linked Polyethylene: A Review of Studies with a Follow-Up of over 15 Years
title_full Wear, Osteolysis, and Aseptic Loosening Following Total Hip Arthroplasty in Young Patients with Highly Cross-Linked Polyethylene: A Review of Studies with a Follow-Up of over 15 Years
title_fullStr Wear, Osteolysis, and Aseptic Loosening Following Total Hip Arthroplasty in Young Patients with Highly Cross-Linked Polyethylene: A Review of Studies with a Follow-Up of over 15 Years
title_full_unstemmed Wear, Osteolysis, and Aseptic Loosening Following Total Hip Arthroplasty in Young Patients with Highly Cross-Linked Polyethylene: A Review of Studies with a Follow-Up of over 15 Years
title_short Wear, Osteolysis, and Aseptic Loosening Following Total Hip Arthroplasty in Young Patients with Highly Cross-Linked Polyethylene: A Review of Studies with a Follow-Up of over 15 Years
title_sort wear, osteolysis, and aseptic loosening following total hip arthroplasty in young patients with highly cross-linked polyethylene: a review of studies with a follow-up of over 15 years
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10607435/
https://www.ncbi.nlm.nih.gov/pubmed/37892754
http://dx.doi.org/10.3390/jcm12206615
work_keys_str_mv AT deanschristopherf wearosteolysisandasepticlooseningfollowingtotalhiparthroplastyinyoungpatientswithhighlycrosslinkedpolyethyleneareviewofstudieswithafollowupofover15years
AT bucknerbrandtc wearosteolysisandasepticlooseningfollowingtotalhiparthroplastyinyoungpatientswithhighlycrosslinkedpolyethyleneareviewofstudieswithafollowupofover15years
AT garvinkevinl wearosteolysisandasepticlooseningfollowingtotalhiparthroplastyinyoungpatientswithhighlycrosslinkedpolyethyleneareviewofstudieswithafollowupofover15years