Cargando…

Development and Validation of LC-MS/MS Method for Determination of Cytisine in Human Serum and Saliva

Cytisine (CYT) is a quinolizidine alkaloid used for nicotine addiction treatment. Recent clinical trial data regarding cytisine confirm its high effectiveness and safety as a smoking cessation treatment. CYT’s popularity is growing due to its increased availability and licensing in more countries wo...

Descripción completa

Detalles Bibliográficos
Autores principales: Wróblewski, Karol, Szultka-Młyńska, Małgorzata, Courtney, Ryan J., Buszewski, Bogusław, Tutka, Piotr
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10607646/
https://www.ncbi.nlm.nih.gov/pubmed/37895042
http://dx.doi.org/10.3390/ijms242015364
_version_ 1785127590931988480
author Wróblewski, Karol
Szultka-Młyńska, Małgorzata
Courtney, Ryan J.
Buszewski, Bogusław
Tutka, Piotr
author_facet Wróblewski, Karol
Szultka-Młyńska, Małgorzata
Courtney, Ryan J.
Buszewski, Bogusław
Tutka, Piotr
author_sort Wróblewski, Karol
collection PubMed
description Cytisine (CYT) is a quinolizidine alkaloid used for nicotine addiction treatment. Recent clinical trial data regarding cytisine confirm its high effectiveness and safety as a smoking cessation treatment. CYT’s popularity is growing due to its increased availability and licensing in more countries worldwide. This increased use by smokers has also resulted in an urgent need for continued drug research, including developing appropriate analytical methods for analyzing the drug in biological samples. In this study, a simple, fast, and reliable method combining hydrophilic interaction liquid chromatography and electrospray ionization quadrupole time of flight mass spectrometry (HILIC/ESI-QTOF-MS) for the determination of CYT in human serum and saliva was developed and validated. This was undertaken after the previous pre-treatment of the sample using solid-phase extraction (SPE). A hydrophilic interaction liquid chromatography (HILIC) column with a silica stationary phase was used for chromatographic analysis. In a linear gradient, the mobile phase consisted of acetonitrile (ACN) and formate buffer at pH 4.0. The proposed method was fully validated and demonstrated its sensitivity, selectivity, precision, and accuracy. The method was successfully applied to determine CYT in serum and, for the first time, in saliva. The findings indicate that saliva could be a promising non-invasive alternative to measure the free concentration of CYT.
format Online
Article
Text
id pubmed-10607646
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106076462023-10-28 Development and Validation of LC-MS/MS Method for Determination of Cytisine in Human Serum and Saliva Wróblewski, Karol Szultka-Młyńska, Małgorzata Courtney, Ryan J. Buszewski, Bogusław Tutka, Piotr Int J Mol Sci Article Cytisine (CYT) is a quinolizidine alkaloid used for nicotine addiction treatment. Recent clinical trial data regarding cytisine confirm its high effectiveness and safety as a smoking cessation treatment. CYT’s popularity is growing due to its increased availability and licensing in more countries worldwide. This increased use by smokers has also resulted in an urgent need for continued drug research, including developing appropriate analytical methods for analyzing the drug in biological samples. In this study, a simple, fast, and reliable method combining hydrophilic interaction liquid chromatography and electrospray ionization quadrupole time of flight mass spectrometry (HILIC/ESI-QTOF-MS) for the determination of CYT in human serum and saliva was developed and validated. This was undertaken after the previous pre-treatment of the sample using solid-phase extraction (SPE). A hydrophilic interaction liquid chromatography (HILIC) column with a silica stationary phase was used for chromatographic analysis. In a linear gradient, the mobile phase consisted of acetonitrile (ACN) and formate buffer at pH 4.0. The proposed method was fully validated and demonstrated its sensitivity, selectivity, precision, and accuracy. The method was successfully applied to determine CYT in serum and, for the first time, in saliva. The findings indicate that saliva could be a promising non-invasive alternative to measure the free concentration of CYT. MDPI 2023-10-19 /pmc/articles/PMC10607646/ /pubmed/37895042 http://dx.doi.org/10.3390/ijms242015364 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wróblewski, Karol
Szultka-Młyńska, Małgorzata
Courtney, Ryan J.
Buszewski, Bogusław
Tutka, Piotr
Development and Validation of LC-MS/MS Method for Determination of Cytisine in Human Serum and Saliva
title Development and Validation of LC-MS/MS Method for Determination of Cytisine in Human Serum and Saliva
title_full Development and Validation of LC-MS/MS Method for Determination of Cytisine in Human Serum and Saliva
title_fullStr Development and Validation of LC-MS/MS Method for Determination of Cytisine in Human Serum and Saliva
title_full_unstemmed Development and Validation of LC-MS/MS Method for Determination of Cytisine in Human Serum and Saliva
title_short Development and Validation of LC-MS/MS Method for Determination of Cytisine in Human Serum and Saliva
title_sort development and validation of lc-ms/ms method for determination of cytisine in human serum and saliva
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10607646/
https://www.ncbi.nlm.nih.gov/pubmed/37895042
http://dx.doi.org/10.3390/ijms242015364
work_keys_str_mv AT wroblewskikarol developmentandvalidationoflcmsmsmethodfordeterminationofcytisineinhumanserumandsaliva
AT szultkamłynskamałgorzata developmentandvalidationoflcmsmsmethodfordeterminationofcytisineinhumanserumandsaliva
AT courtneyryanj developmentandvalidationoflcmsmsmethodfordeterminationofcytisineinhumanserumandsaliva
AT buszewskibogusław developmentandvalidationoflcmsmsmethodfordeterminationofcytisineinhumanserumandsaliva
AT tutkapiotr developmentandvalidationoflcmsmsmethodfordeterminationofcytisineinhumanserumandsaliva