Accuracy of the Injection-Based Occlusion Tool Utilizing Saline and Glucose Solution in Cryoballoon Ablation Guided by a Novel Dielectric Imaging System
Introduction: The aim of this study is to assess the accuracy of the injection-based occlusion (IBO) tool utilizing saline and glucose solution in verifying pulmonary vein (PV) occlusion during cryoballoon ablation guided by a novel dielectric system (KODEX–EPD system). Methods: In this retrospectiv...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10607856/ https://www.ncbi.nlm.nih.gov/pubmed/37887874 http://dx.doi.org/10.3390/jcdd10100427 |
_version_ | 1785127641843499008 |
---|---|
author | Mo, Binfeng Yuan, Jiali Lian, Xiaoming Cai, Xingxing Wang, Qunshan Li, Yigang |
author_facet | Mo, Binfeng Yuan, Jiali Lian, Xiaoming Cai, Xingxing Wang, Qunshan Li, Yigang |
author_sort | Mo, Binfeng |
collection | PubMed |
description | Introduction: The aim of this study is to assess the accuracy of the injection-based occlusion (IBO) tool utilizing saline and glucose solution in verifying pulmonary vein (PV) occlusion during cryoballoon ablation guided by a novel dielectric system (KODEX–EPD system). Methods: In this retrospective study, we enrolled 34 consecutive patients with paroxysmal atrial fibrillation (AF) who underwent their initial cryoballoon ablation procedure guided by the KODEX-EPD system. PV occlusion was firstly assessed by the IBO tool utilizing saline or glucose solution and then verified by direct contrast angiography. Patients were divided into two groups according to the fluid used in the IBO tool: the Saline Group and the Glucose Group. Results: The overall procedure time and fluoroscopy time were comparable between the Saline Group and the Glucose Group (113.7 ± 18.3 vs. 108.4 ± 15.9 min; p = 0.375 and 10.1 ± 3.7 vs. 9.3 ± 3.5 min; p = 0.559). The IBO tool was utilized a total of 138 times in the Saline Group and 135 times in the Glucose Group. When assessing PV occlusion, the IBO tool using saline demonstrated a sensitivity of 92.6% and a specificity of 95.2% compared to angiography. Similarly, the IBO tool utilizing glucose solution showed a sensitivity of 93.2% and a specificity of 96.1%. Conclusions: The IBO tool utilizing non-contrast fluid, saline and glucose solution, demonstrates a high level of sensitivity and specificity in accurately predicting PV occlusion during cryoablation procedures. Both the saline and glucose solutions used in the IBO tool show promising results in effectively assessing PV occlusion. |
format | Online Article Text |
id | pubmed-10607856 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106078562023-10-28 Accuracy of the Injection-Based Occlusion Tool Utilizing Saline and Glucose Solution in Cryoballoon Ablation Guided by a Novel Dielectric Imaging System Mo, Binfeng Yuan, Jiali Lian, Xiaoming Cai, Xingxing Wang, Qunshan Li, Yigang J Cardiovasc Dev Dis Article Introduction: The aim of this study is to assess the accuracy of the injection-based occlusion (IBO) tool utilizing saline and glucose solution in verifying pulmonary vein (PV) occlusion during cryoballoon ablation guided by a novel dielectric system (KODEX–EPD system). Methods: In this retrospective study, we enrolled 34 consecutive patients with paroxysmal atrial fibrillation (AF) who underwent their initial cryoballoon ablation procedure guided by the KODEX-EPD system. PV occlusion was firstly assessed by the IBO tool utilizing saline or glucose solution and then verified by direct contrast angiography. Patients were divided into two groups according to the fluid used in the IBO tool: the Saline Group and the Glucose Group. Results: The overall procedure time and fluoroscopy time were comparable between the Saline Group and the Glucose Group (113.7 ± 18.3 vs. 108.4 ± 15.9 min; p = 0.375 and 10.1 ± 3.7 vs. 9.3 ± 3.5 min; p = 0.559). The IBO tool was utilized a total of 138 times in the Saline Group and 135 times in the Glucose Group. When assessing PV occlusion, the IBO tool using saline demonstrated a sensitivity of 92.6% and a specificity of 95.2% compared to angiography. Similarly, the IBO tool utilizing glucose solution showed a sensitivity of 93.2% and a specificity of 96.1%. Conclusions: The IBO tool utilizing non-contrast fluid, saline and glucose solution, demonstrates a high level of sensitivity and specificity in accurately predicting PV occlusion during cryoablation procedures. Both the saline and glucose solutions used in the IBO tool show promising results in effectively assessing PV occlusion. MDPI 2023-10-17 /pmc/articles/PMC10607856/ /pubmed/37887874 http://dx.doi.org/10.3390/jcdd10100427 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Mo, Binfeng Yuan, Jiali Lian, Xiaoming Cai, Xingxing Wang, Qunshan Li, Yigang Accuracy of the Injection-Based Occlusion Tool Utilizing Saline and Glucose Solution in Cryoballoon Ablation Guided by a Novel Dielectric Imaging System |
title | Accuracy of the Injection-Based Occlusion Tool Utilizing Saline and Glucose Solution in Cryoballoon Ablation Guided by a Novel Dielectric Imaging System |
title_full | Accuracy of the Injection-Based Occlusion Tool Utilizing Saline and Glucose Solution in Cryoballoon Ablation Guided by a Novel Dielectric Imaging System |
title_fullStr | Accuracy of the Injection-Based Occlusion Tool Utilizing Saline and Glucose Solution in Cryoballoon Ablation Guided by a Novel Dielectric Imaging System |
title_full_unstemmed | Accuracy of the Injection-Based Occlusion Tool Utilizing Saline and Glucose Solution in Cryoballoon Ablation Guided by a Novel Dielectric Imaging System |
title_short | Accuracy of the Injection-Based Occlusion Tool Utilizing Saline and Glucose Solution in Cryoballoon Ablation Guided by a Novel Dielectric Imaging System |
title_sort | accuracy of the injection-based occlusion tool utilizing saline and glucose solution in cryoballoon ablation guided by a novel dielectric imaging system |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10607856/ https://www.ncbi.nlm.nih.gov/pubmed/37887874 http://dx.doi.org/10.3390/jcdd10100427 |
work_keys_str_mv | AT mobinfeng accuracyoftheinjectionbasedocclusiontoolutilizingsalineandglucosesolutionincryoballoonablationguidedbyanoveldielectricimagingsystem AT yuanjiali accuracyoftheinjectionbasedocclusiontoolutilizingsalineandglucosesolutionincryoballoonablationguidedbyanoveldielectricimagingsystem AT lianxiaoming accuracyoftheinjectionbasedocclusiontoolutilizingsalineandglucosesolutionincryoballoonablationguidedbyanoveldielectricimagingsystem AT caixingxing accuracyoftheinjectionbasedocclusiontoolutilizingsalineandglucosesolutionincryoballoonablationguidedbyanoveldielectricimagingsystem AT wangqunshan accuracyoftheinjectionbasedocclusiontoolutilizingsalineandglucosesolutionincryoballoonablationguidedbyanoveldielectricimagingsystem AT liyigang accuracyoftheinjectionbasedocclusiontoolutilizingsalineandglucosesolutionincryoballoonablationguidedbyanoveldielectricimagingsystem |