Cargando…

The Influence of Slice Thickness, Sharpness, and Contrast Adjustments on Inferior Alveolar Canal Segmentation on Cone-Beam Computed Tomography Scans: A Retrospective Study

This retrospective study aims to investigate the impact of cone-beam computed tomography (CBCT) viewing parameters such as contrast, slice thickness, and sharpness on the identification of the inferior alveolar nerve (IAC). A total of 25 CBCT scans, resulting in 50 IACs, were assessed by two investi...

Descripción completa

Detalles Bibliográficos
Autores principales: Issa, Julien, Riad, Abanoub, Olszewski, Raphael, Dyszkiewicz-Konwińska, Marta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10608141/
https://www.ncbi.nlm.nih.gov/pubmed/37888129
http://dx.doi.org/10.3390/jpm13101518
_version_ 1785127710221139968
author Issa, Julien
Riad, Abanoub
Olszewski, Raphael
Dyszkiewicz-Konwińska, Marta
author_facet Issa, Julien
Riad, Abanoub
Olszewski, Raphael
Dyszkiewicz-Konwińska, Marta
author_sort Issa, Julien
collection PubMed
description This retrospective study aims to investigate the impact of cone-beam computed tomography (CBCT) viewing parameters such as contrast, slice thickness, and sharpness on the identification of the inferior alveolar nerve (IAC). A total of 25 CBCT scans, resulting in 50 IACs, were assessed by two investigators using a three-score system (good, average, and poor) on cross-sectional images. Slice thicknesses of 0.25 mm, 0.5 mm, and 1 mm were tested, along with varying sharpness (0, 6, 8, and 10) and contrast (0, 400, 800, and 1200) settings. The results were statistically analyzed to determine the optimal slice thickness for improved visibility of IAC, followed by evaluating the influence of sharpness and contrast using the optimal thickness. The identified parameters were then validated by performing semi-automated segmentation of the IACs and structure overlapping to evaluate the mean distance. Inter-rater and intra-rater reliability were assessed using Kappa statistics, and inferential statistics used Pearson’s Chi-square test. Inter-rater and intra-rater reliability for all parameters were significant, ranging from 69% to 83%. A slice thickness of 0.25 mm showed consistently “good” visibility (80%). Sharpness values of zero and contrast values of 1200 also demonstrated high frequencies of “good” visibility. Overlap analysis resulted in an average mean distance of 0.295 mm and a standard deviation of 0.307 mm across all patients’ sides. The study revealed that a slice thickness of 0.25 mm, zero sharpness value, and higher contrast value of 1200 improved the visibility and accuracy of IAC segmentation in CBCT scans. The individual patient’s characteristics, such as anatomical variations, decreased bone density, and absence of canal walls cortication, should be considered when using these parameters.
format Online
Article
Text
id pubmed-10608141
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106081412023-10-28 The Influence of Slice Thickness, Sharpness, and Contrast Adjustments on Inferior Alveolar Canal Segmentation on Cone-Beam Computed Tomography Scans: A Retrospective Study Issa, Julien Riad, Abanoub Olszewski, Raphael Dyszkiewicz-Konwińska, Marta J Pers Med Article This retrospective study aims to investigate the impact of cone-beam computed tomography (CBCT) viewing parameters such as contrast, slice thickness, and sharpness on the identification of the inferior alveolar nerve (IAC). A total of 25 CBCT scans, resulting in 50 IACs, were assessed by two investigators using a three-score system (good, average, and poor) on cross-sectional images. Slice thicknesses of 0.25 mm, 0.5 mm, and 1 mm were tested, along with varying sharpness (0, 6, 8, and 10) and contrast (0, 400, 800, and 1200) settings. The results were statistically analyzed to determine the optimal slice thickness for improved visibility of IAC, followed by evaluating the influence of sharpness and contrast using the optimal thickness. The identified parameters were then validated by performing semi-automated segmentation of the IACs and structure overlapping to evaluate the mean distance. Inter-rater and intra-rater reliability were assessed using Kappa statistics, and inferential statistics used Pearson’s Chi-square test. Inter-rater and intra-rater reliability for all parameters were significant, ranging from 69% to 83%. A slice thickness of 0.25 mm showed consistently “good” visibility (80%). Sharpness values of zero and contrast values of 1200 also demonstrated high frequencies of “good” visibility. Overlap analysis resulted in an average mean distance of 0.295 mm and a standard deviation of 0.307 mm across all patients’ sides. The study revealed that a slice thickness of 0.25 mm, zero sharpness value, and higher contrast value of 1200 improved the visibility and accuracy of IAC segmentation in CBCT scans. The individual patient’s characteristics, such as anatomical variations, decreased bone density, and absence of canal walls cortication, should be considered when using these parameters. MDPI 2023-10-22 /pmc/articles/PMC10608141/ /pubmed/37888129 http://dx.doi.org/10.3390/jpm13101518 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Issa, Julien
Riad, Abanoub
Olszewski, Raphael
Dyszkiewicz-Konwińska, Marta
The Influence of Slice Thickness, Sharpness, and Contrast Adjustments on Inferior Alveolar Canal Segmentation on Cone-Beam Computed Tomography Scans: A Retrospective Study
title The Influence of Slice Thickness, Sharpness, and Contrast Adjustments on Inferior Alveolar Canal Segmentation on Cone-Beam Computed Tomography Scans: A Retrospective Study
title_full The Influence of Slice Thickness, Sharpness, and Contrast Adjustments on Inferior Alveolar Canal Segmentation on Cone-Beam Computed Tomography Scans: A Retrospective Study
title_fullStr The Influence of Slice Thickness, Sharpness, and Contrast Adjustments on Inferior Alveolar Canal Segmentation on Cone-Beam Computed Tomography Scans: A Retrospective Study
title_full_unstemmed The Influence of Slice Thickness, Sharpness, and Contrast Adjustments on Inferior Alveolar Canal Segmentation on Cone-Beam Computed Tomography Scans: A Retrospective Study
title_short The Influence of Slice Thickness, Sharpness, and Contrast Adjustments on Inferior Alveolar Canal Segmentation on Cone-Beam Computed Tomography Scans: A Retrospective Study
title_sort influence of slice thickness, sharpness, and contrast adjustments on inferior alveolar canal segmentation on cone-beam computed tomography scans: a retrospective study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10608141/
https://www.ncbi.nlm.nih.gov/pubmed/37888129
http://dx.doi.org/10.3390/jpm13101518
work_keys_str_mv AT issajulien theinfluenceofslicethicknesssharpnessandcontrastadjustmentsoninferioralveolarcanalsegmentationonconebeamcomputedtomographyscansaretrospectivestudy
AT riadabanoub theinfluenceofslicethicknesssharpnessandcontrastadjustmentsoninferioralveolarcanalsegmentationonconebeamcomputedtomographyscansaretrospectivestudy
AT olszewskiraphael theinfluenceofslicethicknesssharpnessandcontrastadjustmentsoninferioralveolarcanalsegmentationonconebeamcomputedtomographyscansaretrospectivestudy
AT dyszkiewiczkonwinskamarta theinfluenceofslicethicknesssharpnessandcontrastadjustmentsoninferioralveolarcanalsegmentationonconebeamcomputedtomographyscansaretrospectivestudy
AT issajulien influenceofslicethicknesssharpnessandcontrastadjustmentsoninferioralveolarcanalsegmentationonconebeamcomputedtomographyscansaretrospectivestudy
AT riadabanoub influenceofslicethicknesssharpnessandcontrastadjustmentsoninferioralveolarcanalsegmentationonconebeamcomputedtomographyscansaretrospectivestudy
AT olszewskiraphael influenceofslicethicknesssharpnessandcontrastadjustmentsoninferioralveolarcanalsegmentationonconebeamcomputedtomographyscansaretrospectivestudy
AT dyszkiewiczkonwinskamarta influenceofslicethicknesssharpnessandcontrastadjustmentsoninferioralveolarcanalsegmentationonconebeamcomputedtomographyscansaretrospectivestudy