Cargando…
K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury
We present a case of a 16-year-old male with a Salter-Harris type II physeal slip of the distal femur managed with closed reduction and K wire and clamp-based external fixator. Knee range of motion exercises were initiated after one week. The union was observed at 10 weeks, and implant removal was d...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10608687/ https://www.ncbi.nlm.nih.gov/pubmed/37900479 http://dx.doi.org/10.7759/cureus.46070 |
_version_ | 1785127839247368192 |
---|---|
author | Sinha, Siddhartha Aggarwal, Neel Kumar, Arvind Singh, Lokendra Iqbal, Asif Qureshi, Owais A Kumar, Sandeep Jameel, Javed |
author_facet | Sinha, Siddhartha Aggarwal, Neel Kumar, Arvind Singh, Lokendra Iqbal, Asif Qureshi, Owais A Kumar, Sandeep Jameel, Javed |
author_sort | Sinha, Siddhartha |
collection | PubMed |
description | We present a case of a 16-year-old male with a Salter-Harris type II physeal slip of the distal femur managed with closed reduction and K wire and clamp-based external fixator. Knee range of motion exercises were initiated after one week. The union was observed at 10 weeks, and implant removal was done on an outpatient basis. At one year follow-up, the patient had good clinical and radiological outcomes. The K-wire-based external fixator frame is an effective fixation method for distal femur physeal slips in older children, providing favorable radiological and functional outcomes. |
format | Online Article Text |
id | pubmed-10608687 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-106086872023-10-28 K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury Sinha, Siddhartha Aggarwal, Neel Kumar, Arvind Singh, Lokendra Iqbal, Asif Qureshi, Owais A Kumar, Sandeep Jameel, Javed Cureus Orthopedics We present a case of a 16-year-old male with a Salter-Harris type II physeal slip of the distal femur managed with closed reduction and K wire and clamp-based external fixator. Knee range of motion exercises were initiated after one week. The union was observed at 10 weeks, and implant removal was done on an outpatient basis. At one year follow-up, the patient had good clinical and radiological outcomes. The K-wire-based external fixator frame is an effective fixation method for distal femur physeal slips in older children, providing favorable radiological and functional outcomes. Cureus 2023-09-27 /pmc/articles/PMC10608687/ /pubmed/37900479 http://dx.doi.org/10.7759/cureus.46070 Text en Copyright © 2023, Sinha et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Orthopedics Sinha, Siddhartha Aggarwal, Neel Kumar, Arvind Singh, Lokendra Iqbal, Asif Qureshi, Owais A Kumar, Sandeep Jameel, Javed K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury |
title | K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury |
title_full | K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury |
title_fullStr | K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury |
title_full_unstemmed | K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury |
title_short | K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury |
title_sort | k-wire-based external fixator for management of salter-harris type-ii distal femur physeal injury |
topic | Orthopedics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10608687/ https://www.ncbi.nlm.nih.gov/pubmed/37900479 http://dx.doi.org/10.7759/cureus.46070 |
work_keys_str_mv | AT sinhasiddhartha kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury AT aggarwalneel kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury AT kumararvind kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury AT singhlokendra kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury AT iqbalasif kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury AT qureshiowaisa kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury AT kumarsandeep kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury AT jameeljaved kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury |