Cargando…

K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury

We present a case of a 16-year-old male with a Salter-Harris type II physeal slip of the distal femur managed with closed reduction and K wire and clamp-based external fixator. Knee range of motion exercises were initiated after one week. The union was observed at 10 weeks, and implant removal was d...

Descripción completa

Detalles Bibliográficos
Autores principales: Sinha, Siddhartha, Aggarwal, Neel, Kumar, Arvind, Singh, Lokendra, Iqbal, Asif, Qureshi, Owais A, Kumar, Sandeep, Jameel, Javed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10608687/
https://www.ncbi.nlm.nih.gov/pubmed/37900479
http://dx.doi.org/10.7759/cureus.46070
_version_ 1785127839247368192
author Sinha, Siddhartha
Aggarwal, Neel
Kumar, Arvind
Singh, Lokendra
Iqbal, Asif
Qureshi, Owais A
Kumar, Sandeep
Jameel, Javed
author_facet Sinha, Siddhartha
Aggarwal, Neel
Kumar, Arvind
Singh, Lokendra
Iqbal, Asif
Qureshi, Owais A
Kumar, Sandeep
Jameel, Javed
author_sort Sinha, Siddhartha
collection PubMed
description We present a case of a 16-year-old male with a Salter-Harris type II physeal slip of the distal femur managed with closed reduction and K wire and clamp-based external fixator. Knee range of motion exercises were initiated after one week. The union was observed at 10 weeks, and implant removal was done on an outpatient basis. At one year follow-up, the patient had good clinical and radiological outcomes. The K-wire-based external fixator frame is an effective fixation method for distal femur physeal slips in older children, providing favorable radiological and functional outcomes.
format Online
Article
Text
id pubmed-10608687
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-106086872023-10-28 K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury Sinha, Siddhartha Aggarwal, Neel Kumar, Arvind Singh, Lokendra Iqbal, Asif Qureshi, Owais A Kumar, Sandeep Jameel, Javed Cureus Orthopedics We present a case of a 16-year-old male with a Salter-Harris type II physeal slip of the distal femur managed with closed reduction and K wire and clamp-based external fixator. Knee range of motion exercises were initiated after one week. The union was observed at 10 weeks, and implant removal was done on an outpatient basis. At one year follow-up, the patient had good clinical and radiological outcomes. The K-wire-based external fixator frame is an effective fixation method for distal femur physeal slips in older children, providing favorable radiological and functional outcomes. Cureus 2023-09-27 /pmc/articles/PMC10608687/ /pubmed/37900479 http://dx.doi.org/10.7759/cureus.46070 Text en Copyright © 2023, Sinha et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopedics
Sinha, Siddhartha
Aggarwal, Neel
Kumar, Arvind
Singh, Lokendra
Iqbal, Asif
Qureshi, Owais A
Kumar, Sandeep
Jameel, Javed
K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury
title K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury
title_full K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury
title_fullStr K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury
title_full_unstemmed K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury
title_short K-Wire-Based External Fixator for Management of Salter-Harris Type-II Distal Femur Physeal Injury
title_sort k-wire-based external fixator for management of salter-harris type-ii distal femur physeal injury
topic Orthopedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10608687/
https://www.ncbi.nlm.nih.gov/pubmed/37900479
http://dx.doi.org/10.7759/cureus.46070
work_keys_str_mv AT sinhasiddhartha kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury
AT aggarwalneel kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury
AT kumararvind kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury
AT singhlokendra kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury
AT iqbalasif kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury
AT qureshiowaisa kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury
AT kumarsandeep kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury
AT jameeljaved kwirebasedexternalfixatorformanagementofsalterharristypeiidistalfemurphysealinjury