Cargando…

Urinary Free Cortisol Determination and Interferences Studies Using Liquid Chromatography Coupled to Tandem Mass Spectrometry after On-Line Solid Phase Extraction Based on Turboflow(TM) Chromatography

(1) A 24 h urinary free cortisol (UFF) is one of the first-line exams recommended for the diagnosis of Cushing’s syndrome. In a hospital hormonology department, this activity can exceed several hundred dosages per week. The UFF is generally determined via an immunoassay with an automate using a chem...

Descripción completa

Detalles Bibliográficos
Autores principales: Bonnet-Serrano, Fidéline, Nakib, Samir, Zientek, Corinne, Guignat, Laurence, Guibourdenche, Jean, Bertherat, Jerôme, Menet, Marie-Claude
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10608966/
https://www.ncbi.nlm.nih.gov/pubmed/37887388
http://dx.doi.org/10.3390/metabo13101063
_version_ 1785127902544658432
author Bonnet-Serrano, Fidéline
Nakib, Samir
Zientek, Corinne
Guignat, Laurence
Guibourdenche, Jean
Bertherat, Jerôme
Menet, Marie-Claude
author_facet Bonnet-Serrano, Fidéline
Nakib, Samir
Zientek, Corinne
Guignat, Laurence
Guibourdenche, Jean
Bertherat, Jerôme
Menet, Marie-Claude
author_sort Bonnet-Serrano, Fidéline
collection PubMed
description (1) A 24 h urinary free cortisol (UFF) is one of the first-line exams recommended for the diagnosis of Cushing’s syndrome. In a hospital hormonology department, this activity can exceed several hundred dosages per week. The UFF is generally determined via an immunoassay with an automate using a chemiluminescence or electrochemiluminescence detection system. To increase the cortisol concentration in the analyzed sample, the automated analysis is preceded by urine extraction, which does not prevent there from being some interferences due to other steroids with close structures. (2) This paper describes the development of on-line solid phase extraction coupled to liquid chromatography and mass spectrometry for the analysis of urinary free cortisol. The on-line extraction was based on the Turboflow(TM) chromatography coupled to the analytical column by two valves, easily available for the laboratories. (3) The choice of the Accucore Polar Premium(®) analytical column made it possible to avoid analytical interferences with exogenous or endogenous molecules having the same SRM transition (363 → 121) as cortisol. (4) The method was fully validated in the range of clinically relevant concentrations from the lower limit of quantification (LLOQ) to 411.75 nmol·L(−1).
format Online
Article
Text
id pubmed-10608966
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106089662023-10-28 Urinary Free Cortisol Determination and Interferences Studies Using Liquid Chromatography Coupled to Tandem Mass Spectrometry after On-Line Solid Phase Extraction Based on Turboflow(TM) Chromatography Bonnet-Serrano, Fidéline Nakib, Samir Zientek, Corinne Guignat, Laurence Guibourdenche, Jean Bertherat, Jerôme Menet, Marie-Claude Metabolites Article (1) A 24 h urinary free cortisol (UFF) is one of the first-line exams recommended for the diagnosis of Cushing’s syndrome. In a hospital hormonology department, this activity can exceed several hundred dosages per week. The UFF is generally determined via an immunoassay with an automate using a chemiluminescence or electrochemiluminescence detection system. To increase the cortisol concentration in the analyzed sample, the automated analysis is preceded by urine extraction, which does not prevent there from being some interferences due to other steroids with close structures. (2) This paper describes the development of on-line solid phase extraction coupled to liquid chromatography and mass spectrometry for the analysis of urinary free cortisol. The on-line extraction was based on the Turboflow(TM) chromatography coupled to the analytical column by two valves, easily available for the laboratories. (3) The choice of the Accucore Polar Premium(®) analytical column made it possible to avoid analytical interferences with exogenous or endogenous molecules having the same SRM transition (363 → 121) as cortisol. (4) The method was fully validated in the range of clinically relevant concentrations from the lower limit of quantification (LLOQ) to 411.75 nmol·L(−1). MDPI 2023-10-09 /pmc/articles/PMC10608966/ /pubmed/37887388 http://dx.doi.org/10.3390/metabo13101063 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bonnet-Serrano, Fidéline
Nakib, Samir
Zientek, Corinne
Guignat, Laurence
Guibourdenche, Jean
Bertherat, Jerôme
Menet, Marie-Claude
Urinary Free Cortisol Determination and Interferences Studies Using Liquid Chromatography Coupled to Tandem Mass Spectrometry after On-Line Solid Phase Extraction Based on Turboflow(TM) Chromatography
title Urinary Free Cortisol Determination and Interferences Studies Using Liquid Chromatography Coupled to Tandem Mass Spectrometry after On-Line Solid Phase Extraction Based on Turboflow(TM) Chromatography
title_full Urinary Free Cortisol Determination and Interferences Studies Using Liquid Chromatography Coupled to Tandem Mass Spectrometry after On-Line Solid Phase Extraction Based on Turboflow(TM) Chromatography
title_fullStr Urinary Free Cortisol Determination and Interferences Studies Using Liquid Chromatography Coupled to Tandem Mass Spectrometry after On-Line Solid Phase Extraction Based on Turboflow(TM) Chromatography
title_full_unstemmed Urinary Free Cortisol Determination and Interferences Studies Using Liquid Chromatography Coupled to Tandem Mass Spectrometry after On-Line Solid Phase Extraction Based on Turboflow(TM) Chromatography
title_short Urinary Free Cortisol Determination and Interferences Studies Using Liquid Chromatography Coupled to Tandem Mass Spectrometry after On-Line Solid Phase Extraction Based on Turboflow(TM) Chromatography
title_sort urinary free cortisol determination and interferences studies using liquid chromatography coupled to tandem mass spectrometry after on-line solid phase extraction based on turboflow(tm) chromatography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10608966/
https://www.ncbi.nlm.nih.gov/pubmed/37887388
http://dx.doi.org/10.3390/metabo13101063
work_keys_str_mv AT bonnetserranofideline urinaryfreecortisoldeterminationandinterferencesstudiesusingliquidchromatographycoupledtotandemmassspectrometryafteronlinesolidphaseextractionbasedonturboflowtmchromatography
AT nakibsamir urinaryfreecortisoldeterminationandinterferencesstudiesusingliquidchromatographycoupledtotandemmassspectrometryafteronlinesolidphaseextractionbasedonturboflowtmchromatography
AT zientekcorinne urinaryfreecortisoldeterminationandinterferencesstudiesusingliquidchromatographycoupledtotandemmassspectrometryafteronlinesolidphaseextractionbasedonturboflowtmchromatography
AT guignatlaurence urinaryfreecortisoldeterminationandinterferencesstudiesusingliquidchromatographycoupledtotandemmassspectrometryafteronlinesolidphaseextractionbasedonturboflowtmchromatography
AT guibourdenchejean urinaryfreecortisoldeterminationandinterferencesstudiesusingliquidchromatographycoupledtotandemmassspectrometryafteronlinesolidphaseextractionbasedonturboflowtmchromatography
AT bertheratjerome urinaryfreecortisoldeterminationandinterferencesstudiesusingliquidchromatographycoupledtotandemmassspectrometryafteronlinesolidphaseextractionbasedonturboflowtmchromatography
AT menetmarieclaude urinaryfreecortisoldeterminationandinterferencesstudiesusingliquidchromatographycoupledtotandemmassspectrometryafteronlinesolidphaseextractionbasedonturboflowtmchromatography