Cargando…
Greener and Whiter Analytical Chemistry Using Cyrene as a More Sustainable and Eco-Friendlier Mobile Phase Constituent in Chromatography
Cyrene (dihydrolevoglucosenone) was evaluated for the first time as a potential sustainable mobile phase solvent in reversed-phase chromatography. As a benign biodegradable solvent, Cyrene is an attractive replacement to classical non-green organic chromatographic solvents such as acetonitrile and a...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10609853/ https://www.ncbi.nlm.nih.gov/pubmed/37895959 http://dx.doi.org/10.3390/ph16101488 |
_version_ | 1785128112442310656 |
---|---|
author | El Deeb, Sami Abdelsamad, Khalid Parr, Maria Kristina |
author_facet | El Deeb, Sami Abdelsamad, Khalid Parr, Maria Kristina |
author_sort | El Deeb, Sami |
collection | PubMed |
description | Cyrene (dihydrolevoglucosenone) was evaluated for the first time as a potential sustainable mobile phase solvent in reversed-phase chromatography. As a benign biodegradable solvent, Cyrene is an attractive replacement to classical non-green organic chromatographic solvents such as acetonitrile and a modifier, co-eluent to known green solvents such as ethanol. Compared to ethanol, Cyrene is less toxic, non-flammable, biobased, biodegradable, and a cheaper solvent. A fire safety spider chart was generated to compare the properties of Cyrene to ethanol and show its superiority as a greener solvent. Cyrene’s behavior, advantages, and drawbacks in reversed-phase chromatography, including the cut-off value of 350 nm, elution power, selectivity, and effect on the column, were investigated using a model drug mixture of moxifloxacin and metronidazole. A monolithic C(18) (100 × 4.6 mm) column was used as a stationary phase. Different ratios of Cyrene: ethanol with an aqueous portion of sodium acetate buffer mobile phases were tested. A mobile phase consisting of Cyrene: ethanol: 0.1 M sodium acetate buffer pH 4.25 (8:13:79, v/v/v) was selected as the most suitable mobile phase system for separating and simultaneously determining metronidazole and moxifloxacin. The greenness and whiteness of the method were evaluated using the qualitative green assessment tool AGREE and the white analytical chemistry assessment tool RGB12. Further potentials of Cyrene as a solvent or modifier in normal phase chromatography, liquid chromatography–mass spectrometry, and supercritical fluid chromatography are discussed. |
format | Online Article Text |
id | pubmed-10609853 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106098532023-10-28 Greener and Whiter Analytical Chemistry Using Cyrene as a More Sustainable and Eco-Friendlier Mobile Phase Constituent in Chromatography El Deeb, Sami Abdelsamad, Khalid Parr, Maria Kristina Pharmaceuticals (Basel) Article Cyrene (dihydrolevoglucosenone) was evaluated for the first time as a potential sustainable mobile phase solvent in reversed-phase chromatography. As a benign biodegradable solvent, Cyrene is an attractive replacement to classical non-green organic chromatographic solvents such as acetonitrile and a modifier, co-eluent to known green solvents such as ethanol. Compared to ethanol, Cyrene is less toxic, non-flammable, biobased, biodegradable, and a cheaper solvent. A fire safety spider chart was generated to compare the properties of Cyrene to ethanol and show its superiority as a greener solvent. Cyrene’s behavior, advantages, and drawbacks in reversed-phase chromatography, including the cut-off value of 350 nm, elution power, selectivity, and effect on the column, were investigated using a model drug mixture of moxifloxacin and metronidazole. A monolithic C(18) (100 × 4.6 mm) column was used as a stationary phase. Different ratios of Cyrene: ethanol with an aqueous portion of sodium acetate buffer mobile phases were tested. A mobile phase consisting of Cyrene: ethanol: 0.1 M sodium acetate buffer pH 4.25 (8:13:79, v/v/v) was selected as the most suitable mobile phase system for separating and simultaneously determining metronidazole and moxifloxacin. The greenness and whiteness of the method were evaluated using the qualitative green assessment tool AGREE and the white analytical chemistry assessment tool RGB12. Further potentials of Cyrene as a solvent or modifier in normal phase chromatography, liquid chromatography–mass spectrometry, and supercritical fluid chromatography are discussed. MDPI 2023-10-19 /pmc/articles/PMC10609853/ /pubmed/37895959 http://dx.doi.org/10.3390/ph16101488 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article El Deeb, Sami Abdelsamad, Khalid Parr, Maria Kristina Greener and Whiter Analytical Chemistry Using Cyrene as a More Sustainable and Eco-Friendlier Mobile Phase Constituent in Chromatography |
title | Greener and Whiter Analytical Chemistry Using Cyrene as a More Sustainable and Eco-Friendlier Mobile Phase Constituent in Chromatography |
title_full | Greener and Whiter Analytical Chemistry Using Cyrene as a More Sustainable and Eco-Friendlier Mobile Phase Constituent in Chromatography |
title_fullStr | Greener and Whiter Analytical Chemistry Using Cyrene as a More Sustainable and Eco-Friendlier Mobile Phase Constituent in Chromatography |
title_full_unstemmed | Greener and Whiter Analytical Chemistry Using Cyrene as a More Sustainable and Eco-Friendlier Mobile Phase Constituent in Chromatography |
title_short | Greener and Whiter Analytical Chemistry Using Cyrene as a More Sustainable and Eco-Friendlier Mobile Phase Constituent in Chromatography |
title_sort | greener and whiter analytical chemistry using cyrene as a more sustainable and eco-friendlier mobile phase constituent in chromatography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10609853/ https://www.ncbi.nlm.nih.gov/pubmed/37895959 http://dx.doi.org/10.3390/ph16101488 |
work_keys_str_mv | AT eldeebsami greenerandwhiteranalyticalchemistryusingcyreneasamoresustainableandecofriendliermobilephaseconstituentinchromatography AT abdelsamadkhalid greenerandwhiteranalyticalchemistryusingcyreneasamoresustainableandecofriendliermobilephaseconstituentinchromatography AT parrmariakristina greenerandwhiteranalyticalchemistryusingcyreneasamoresustainableandecofriendliermobilephaseconstituentinchromatography |