Cargando…

Impacts of Skin Color and Hypoxemia on Noninvasive Assessment of Peripheral Blood Oxygen Saturation: A Scoping Review

Standard pulse oximeters estimate arterial blood saturation (SaO(2)) non-invasively by emitting and detecting light of a specific wavelength through a cutaneous vascular bed, such as a digit or the ear lobe. The quantity measured at these peripheral sites is designated as oxygen saturation (SpO(2))....

Descripción completa

Detalles Bibliográficos
Autores principales: Aoki, Kawaiola C, Barrant, Maya, Gai, Mam Jarra, Handal, Marina, Xu, Vivian, Mayrovitz, Harvey N
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10610303/
https://www.ncbi.nlm.nih.gov/pubmed/37900526
http://dx.doi.org/10.7759/cureus.46078
_version_ 1785128222208294912
author Aoki, Kawaiola C
Barrant, Maya
Gai, Mam Jarra
Handal, Marina
Xu, Vivian
Mayrovitz, Harvey N
author_facet Aoki, Kawaiola C
Barrant, Maya
Gai, Mam Jarra
Handal, Marina
Xu, Vivian
Mayrovitz, Harvey N
author_sort Aoki, Kawaiola C
collection PubMed
description Standard pulse oximeters estimate arterial blood saturation (SaO(2)) non-invasively by emitting and detecting light of a specific wavelength through a cutaneous vascular bed, such as a digit or the ear lobe. The quantity measured at these peripheral sites is designated as oxygen saturation (SpO(2)). Most reliable pulse oximeters are calibrated from measurements of healthy volunteers using some form of oxygen desaturation method. As the degree of inducible hypoxemia is limited, the calibration below achievable desaturation levels is usually extrapolated, leading to potential measurement error at low SaO(2) values, especially in highly pigmented skin. Such skin color-related errors (SCRE) are the topic of this scoping review. Specifically, this study aimed to identify the combined impact of skin color and reduced SaO(2) on the non-invasive assessment of SpO(2 )and report the consequences of potential inaccuracies. Three databases were searched (Cumulated Index to Nursing and Allied Health Literature (CINAHL), PubMed, and Web of Science) for peer-reviewed prospective and retrospective studies published in English between 2000 and 2022 involving human patients with hypoxemia that included a measure of skin color (Fitzpatrick scale or race/ethnicity). Ten studies met the criteria and were included in the final review. Eight of these studies reported statistically significant higher pulse oximeter readings in darker-skinned patients with hypoxia compared to their arterial blood gas measurements. Occult hypoxia was more prevalent in Black and Hispanic patients than in White patients. Minority patients overall (Black, Asian, and American Indian) were more likely to have a SaO(2) < 88% that was not detected by pulse oximetry (occult hypoxemia) during hospitalization. With greater levels of hypoxemia, the differences between SpO(2) and SaO(2 )were greater. If SaO(2) was < 90%, then SpO(2) was overestimated in all ethnicities but worse in minorities. In conclusion, the bias found in pulse oximeter readings in the skin of color broadly impacts patients with hypoxemia. The failure of SpO(2) measuring devices to detect occult hypoxemia can delay the delivery of life-saving treatment to critically ill patients requiring respiratory rehabilitation and supplemental oxygen therapy. This may lead to adverse health outcomes, increased in-hospital mortality, and complications such as organ dysfunction. An improvement in pulse oximeter detection mechanisms that would include all skin pigmentations is therefore much desired to optimize individual healthcare status and minimize disparities in treatment.
format Online
Article
Text
id pubmed-10610303
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-106103032023-10-28 Impacts of Skin Color and Hypoxemia on Noninvasive Assessment of Peripheral Blood Oxygen Saturation: A Scoping Review Aoki, Kawaiola C Barrant, Maya Gai, Mam Jarra Handal, Marina Xu, Vivian Mayrovitz, Harvey N Cureus Internal Medicine Standard pulse oximeters estimate arterial blood saturation (SaO(2)) non-invasively by emitting and detecting light of a specific wavelength through a cutaneous vascular bed, such as a digit or the ear lobe. The quantity measured at these peripheral sites is designated as oxygen saturation (SpO(2)). Most reliable pulse oximeters are calibrated from measurements of healthy volunteers using some form of oxygen desaturation method. As the degree of inducible hypoxemia is limited, the calibration below achievable desaturation levels is usually extrapolated, leading to potential measurement error at low SaO(2) values, especially in highly pigmented skin. Such skin color-related errors (SCRE) are the topic of this scoping review. Specifically, this study aimed to identify the combined impact of skin color and reduced SaO(2) on the non-invasive assessment of SpO(2 )and report the consequences of potential inaccuracies. Three databases were searched (Cumulated Index to Nursing and Allied Health Literature (CINAHL), PubMed, and Web of Science) for peer-reviewed prospective and retrospective studies published in English between 2000 and 2022 involving human patients with hypoxemia that included a measure of skin color (Fitzpatrick scale or race/ethnicity). Ten studies met the criteria and were included in the final review. Eight of these studies reported statistically significant higher pulse oximeter readings in darker-skinned patients with hypoxia compared to their arterial blood gas measurements. Occult hypoxia was more prevalent in Black and Hispanic patients than in White patients. Minority patients overall (Black, Asian, and American Indian) were more likely to have a SaO(2) < 88% that was not detected by pulse oximetry (occult hypoxemia) during hospitalization. With greater levels of hypoxemia, the differences between SpO(2) and SaO(2 )were greater. If SaO(2) was < 90%, then SpO(2) was overestimated in all ethnicities but worse in minorities. In conclusion, the bias found in pulse oximeter readings in the skin of color broadly impacts patients with hypoxemia. The failure of SpO(2) measuring devices to detect occult hypoxemia can delay the delivery of life-saving treatment to critically ill patients requiring respiratory rehabilitation and supplemental oxygen therapy. This may lead to adverse health outcomes, increased in-hospital mortality, and complications such as organ dysfunction. An improvement in pulse oximeter detection mechanisms that would include all skin pigmentations is therefore much desired to optimize individual healthcare status and minimize disparities in treatment. Cureus 2023-09-27 /pmc/articles/PMC10610303/ /pubmed/37900526 http://dx.doi.org/10.7759/cureus.46078 Text en Copyright © 2023, Aoki et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Internal Medicine
Aoki, Kawaiola C
Barrant, Maya
Gai, Mam Jarra
Handal, Marina
Xu, Vivian
Mayrovitz, Harvey N
Impacts of Skin Color and Hypoxemia on Noninvasive Assessment of Peripheral Blood Oxygen Saturation: A Scoping Review
title Impacts of Skin Color and Hypoxemia on Noninvasive Assessment of Peripheral Blood Oxygen Saturation: A Scoping Review
title_full Impacts of Skin Color and Hypoxemia on Noninvasive Assessment of Peripheral Blood Oxygen Saturation: A Scoping Review
title_fullStr Impacts of Skin Color and Hypoxemia on Noninvasive Assessment of Peripheral Blood Oxygen Saturation: A Scoping Review
title_full_unstemmed Impacts of Skin Color and Hypoxemia on Noninvasive Assessment of Peripheral Blood Oxygen Saturation: A Scoping Review
title_short Impacts of Skin Color and Hypoxemia on Noninvasive Assessment of Peripheral Blood Oxygen Saturation: A Scoping Review
title_sort impacts of skin color and hypoxemia on noninvasive assessment of peripheral blood oxygen saturation: a scoping review
topic Internal Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10610303/
https://www.ncbi.nlm.nih.gov/pubmed/37900526
http://dx.doi.org/10.7759/cureus.46078
work_keys_str_mv AT aokikawaiolac impactsofskincolorandhypoxemiaonnoninvasiveassessmentofperipheralbloodoxygensaturationascopingreview
AT barrantmaya impactsofskincolorandhypoxemiaonnoninvasiveassessmentofperipheralbloodoxygensaturationascopingreview
AT gaimamjarra impactsofskincolorandhypoxemiaonnoninvasiveassessmentofperipheralbloodoxygensaturationascopingreview
AT handalmarina impactsofskincolorandhypoxemiaonnoninvasiveassessmentofperipheralbloodoxygensaturationascopingreview
AT xuvivian impactsofskincolorandhypoxemiaonnoninvasiveassessmentofperipheralbloodoxygensaturationascopingreview
AT mayrovitzharveyn impactsofskincolorandhypoxemiaonnoninvasiveassessmentofperipheralbloodoxygensaturationascopingreview