Cargando…

Use of CdZnTe Quasi-Hemispherical Detectors under the Impact of Low Temperatures and High-Gamma Radiation Fluxes

This article discusses the possibilities and limitations of CdZnTe (CZT) quasi-hemispherical detectors operating over a wide temperature range and at high-gamma radiation fluxes. The results of the negative influence of low- and high-operating temperatures, as well as high-radiation fluxes on spectr...

Descripción completa

Detalles Bibliográficos
Autores principales: Ivanov, Victor, Fjodorovs, Viktors, Loutchanski, Anatoli, Piskunovs, Maksims, Ivanovs, Valerijs
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10611207/
https://www.ncbi.nlm.nih.gov/pubmed/37896472
http://dx.doi.org/10.3390/s23208378
_version_ 1785128437175812096
author Ivanov, Victor
Fjodorovs, Viktors
Loutchanski, Anatoli
Piskunovs, Maksims
Ivanovs, Valerijs
author_facet Ivanov, Victor
Fjodorovs, Viktors
Loutchanski, Anatoli
Piskunovs, Maksims
Ivanovs, Valerijs
author_sort Ivanov, Victor
collection PubMed
description This article discusses the possibilities and limitations of CdZnTe (CZT) quasi-hemispherical detectors operating over a wide temperature range and at high-gamma radiation fluxes. The results of the negative influence of low- and high-operating temperatures, as well as high-radiation fluxes on spectrometric characteristics of CZT detectors and possible ways to eliminate performance deterioration, are presented. The impact of infrared (IR) illumination parameters, such as wavelength and irradiation intensity on the spectroscopy performance of detectors, was investigated. A correctly chosen IR illumination wavelength and intensity were shown to significantly improve the energy resolution of CZT quasi-hemispherical detectors, allowing their stable operation in high-gamma radiation fluxes and extend the operating temperature range toward low temperatures. The influences of bias voltage values and temperatures on the quasi-hemispherical CZT detectors’ operating ability at high-gamma radiation fluxes were studied.
format Online
Article
Text
id pubmed-10611207
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106112072023-10-28 Use of CdZnTe Quasi-Hemispherical Detectors under the Impact of Low Temperatures and High-Gamma Radiation Fluxes Ivanov, Victor Fjodorovs, Viktors Loutchanski, Anatoli Piskunovs, Maksims Ivanovs, Valerijs Sensors (Basel) Article This article discusses the possibilities and limitations of CdZnTe (CZT) quasi-hemispherical detectors operating over a wide temperature range and at high-gamma radiation fluxes. The results of the negative influence of low- and high-operating temperatures, as well as high-radiation fluxes on spectrometric characteristics of CZT detectors and possible ways to eliminate performance deterioration, are presented. The impact of infrared (IR) illumination parameters, such as wavelength and irradiation intensity on the spectroscopy performance of detectors, was investigated. A correctly chosen IR illumination wavelength and intensity were shown to significantly improve the energy resolution of CZT quasi-hemispherical detectors, allowing their stable operation in high-gamma radiation fluxes and extend the operating temperature range toward low temperatures. The influences of bias voltage values and temperatures on the quasi-hemispherical CZT detectors’ operating ability at high-gamma radiation fluxes were studied. MDPI 2023-10-10 /pmc/articles/PMC10611207/ /pubmed/37896472 http://dx.doi.org/10.3390/s23208378 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ivanov, Victor
Fjodorovs, Viktors
Loutchanski, Anatoli
Piskunovs, Maksims
Ivanovs, Valerijs
Use of CdZnTe Quasi-Hemispherical Detectors under the Impact of Low Temperatures and High-Gamma Radiation Fluxes
title Use of CdZnTe Quasi-Hemispherical Detectors under the Impact of Low Temperatures and High-Gamma Radiation Fluxes
title_full Use of CdZnTe Quasi-Hemispherical Detectors under the Impact of Low Temperatures and High-Gamma Radiation Fluxes
title_fullStr Use of CdZnTe Quasi-Hemispherical Detectors under the Impact of Low Temperatures and High-Gamma Radiation Fluxes
title_full_unstemmed Use of CdZnTe Quasi-Hemispherical Detectors under the Impact of Low Temperatures and High-Gamma Radiation Fluxes
title_short Use of CdZnTe Quasi-Hemispherical Detectors under the Impact of Low Temperatures and High-Gamma Radiation Fluxes
title_sort use of cdznte quasi-hemispherical detectors under the impact of low temperatures and high-gamma radiation fluxes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10611207/
https://www.ncbi.nlm.nih.gov/pubmed/37896472
http://dx.doi.org/10.3390/s23208378
work_keys_str_mv AT ivanovvictor useofcdzntequasihemisphericaldetectorsundertheimpactoflowtemperaturesandhighgammaradiationfluxes
AT fjodorovsviktors useofcdzntequasihemisphericaldetectorsundertheimpactoflowtemperaturesandhighgammaradiationfluxes
AT loutchanskianatoli useofcdzntequasihemisphericaldetectorsundertheimpactoflowtemperaturesandhighgammaradiationfluxes
AT piskunovsmaksims useofcdzntequasihemisphericaldetectorsundertheimpactoflowtemperaturesandhighgammaradiationfluxes
AT ivanovsvalerijs useofcdzntequasihemisphericaldetectorsundertheimpactoflowtemperaturesandhighgammaradiationfluxes