Enhanced Fault Type Detection in Covered Conductors Using a Stacked Ensemble and Novel Algorithm Combination

This study introduces an innovative approach to enhance fault detection in XLPE-covered conductors used for power distribution systems. These covered conductors are widely utilized in forested areas (natural parks) to decrease the buffer zone and increase the reliability of the distribution network....

Descripción completa

Detalles Bibliográficos
Autores principales: Kabot, Ondřej, Klein, Lukáš, Prokop, Lukáš, Walendziuk, Wojciech
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10611413/
https://www.ncbi.nlm.nih.gov/pubmed/37896448
http://dx.doi.org/10.3390/s23208353
_version_ 1785128485572837376
author Kabot, Ondřej
Klein, Lukáš
Prokop, Lukáš
Walendziuk, Wojciech
author_facet Kabot, Ondřej
Klein, Lukáš
Prokop, Lukáš
Walendziuk, Wojciech
author_sort Kabot, Ondřej
collection PubMed
description This study introduces an innovative approach to enhance fault detection in XLPE-covered conductors used for power distribution systems. These covered conductors are widely utilized in forested areas (natural parks) to decrease the buffer zone and increase the reliability of the distribution network. Recognizing the imperative need for precise fault detection in this context, this research employs an antenna-based method to detect a particular type of fault. The present research contains the classification of fault type detection, which was previously accomplished using a very expensive and challenging-to-install galvanic contact method, and only to a limited extent, which did not provide information about the fault type. Additionally, differentiating between types of faults in the contact method is much easier because information for each phase is available. The proposed method uses antennas and a classifier to effectively differentiate between fault types, ranging from single-phase to three-phase faults, as well as among different types of faults. This has never been done before. To bolster the accuracy, a stacking ensemble method involving the logistic regression is implemented. This approach not only advances precise fault detection but also encourages the broader adoption of covered conductors. This promises benefits such as a reduced buffer zone, improved distribution network reliability, and positive environmental outcomes through accident prevention and safe covered conductor utilization. Additionally, it is suggested that the fault type detection could lead to a decrease in false positives.
format Online
Article
Text
id pubmed-10611413
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106114132023-10-28 Enhanced Fault Type Detection in Covered Conductors Using a Stacked Ensemble and Novel Algorithm Combination Kabot, Ondřej Klein, Lukáš Prokop, Lukáš Walendziuk, Wojciech Sensors (Basel) Article This study introduces an innovative approach to enhance fault detection in XLPE-covered conductors used for power distribution systems. These covered conductors are widely utilized in forested areas (natural parks) to decrease the buffer zone and increase the reliability of the distribution network. Recognizing the imperative need for precise fault detection in this context, this research employs an antenna-based method to detect a particular type of fault. The present research contains the classification of fault type detection, which was previously accomplished using a very expensive and challenging-to-install galvanic contact method, and only to a limited extent, which did not provide information about the fault type. Additionally, differentiating between types of faults in the contact method is much easier because information for each phase is available. The proposed method uses antennas and a classifier to effectively differentiate between fault types, ranging from single-phase to three-phase faults, as well as among different types of faults. This has never been done before. To bolster the accuracy, a stacking ensemble method involving the logistic regression is implemented. This approach not only advances precise fault detection but also encourages the broader adoption of covered conductors. This promises benefits such as a reduced buffer zone, improved distribution network reliability, and positive environmental outcomes through accident prevention and safe covered conductor utilization. Additionally, it is suggested that the fault type detection could lead to a decrease in false positives. MDPI 2023-10-10 /pmc/articles/PMC10611413/ /pubmed/37896448 http://dx.doi.org/10.3390/s23208353 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kabot, Ondřej
Klein, Lukáš
Prokop, Lukáš
Walendziuk, Wojciech
Enhanced Fault Type Detection in Covered Conductors Using a Stacked Ensemble and Novel Algorithm Combination
title Enhanced Fault Type Detection in Covered Conductors Using a Stacked Ensemble and Novel Algorithm Combination
title_full Enhanced Fault Type Detection in Covered Conductors Using a Stacked Ensemble and Novel Algorithm Combination
title_fullStr Enhanced Fault Type Detection in Covered Conductors Using a Stacked Ensemble and Novel Algorithm Combination
title_full_unstemmed Enhanced Fault Type Detection in Covered Conductors Using a Stacked Ensemble and Novel Algorithm Combination
title_short Enhanced Fault Type Detection in Covered Conductors Using a Stacked Ensemble and Novel Algorithm Combination
title_sort enhanced fault type detection in covered conductors using a stacked ensemble and novel algorithm combination
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10611413/
https://www.ncbi.nlm.nih.gov/pubmed/37896448
http://dx.doi.org/10.3390/s23208353
work_keys_str_mv AT kabotondrej enhancedfaulttypedetectionincoveredconductorsusingastackedensembleandnovelalgorithmcombination
AT kleinlukas enhancedfaulttypedetectionincoveredconductorsusingastackedensembleandnovelalgorithmcombination
AT prokoplukas enhancedfaulttypedetectionincoveredconductorsusingastackedensembleandnovelalgorithmcombination
AT walendziukwojciech enhancedfaulttypedetectionincoveredconductorsusingastackedensembleandnovelalgorithmcombination