Cargando…
Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging
OBJECTIVE: Cine magnetic resonance imaging (MRI) has emerged as a noninvasive method to quantitatively assess bowel motility. However, its accuracy in measuring various degrees of small bowel motility has not been extensively evaluated. We aimed to draw a quantitative small bowel motility score from...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10613842/ https://www.ncbi.nlm.nih.gov/pubmed/37724587 http://dx.doi.org/10.3348/kjr.2023.0144 |
_version_ | 1785128913775624192 |
---|---|
author | Choi, Ji Young Yun, Jihye Heo, Subin Kim, Dong Wook Choi, Sang Hyun Yoon, Jiyoung Kim, Kyuwon Jung, Kee Wook Myung, Seung-Jae |
author_facet | Choi, Ji Young Yun, Jihye Heo, Subin Kim, Dong Wook Choi, Sang Hyun Yoon, Jiyoung Kim, Kyuwon Jung, Kee Wook Myung, Seung-Jae |
author_sort | Choi, Ji Young |
collection | PubMed |
description | OBJECTIVE: Cine magnetic resonance imaging (MRI) has emerged as a noninvasive method to quantitatively assess bowel motility. However, its accuracy in measuring various degrees of small bowel motility has not been extensively evaluated. We aimed to draw a quantitative small bowel motility score from cine MRI and evaluate its performance in a population with varying degrees of small bowel motility. MATERIALS AND METHODS: A total of 174 participants (28.5 ± 7.6 years; 135 males) underwent a 22-second-long cine MRI sequence (2-dimensional balanced turbo-field echo; 0.5 seconds per image) approximately 5 minutes after being intravenously administered 10 mg of scopolamine-N-butyl bromide to deliberately create diverse degrees of small bowel motility. In a manually segmented area of the small bowel, motility was automatically quantified using a nonrigid registration and calculated as a quantitative motility score. The mean value (MV) of motility grades visually assessed by two radiologists was used as a reference standard. The quantitative motility score’s correlation (Spearman’s ρ) with the reference standard and performance (area under the receiver operating characteristics curve [AUROC], sensitivity, and specificity) for diagnosing adynamic small bowel (MV of 1) were evaluated. RESULTS: For the MV of the quantitative motility scores at grades 1, 1.5, 2, 2.5, and 3, the mean ± standard deviation values were 0.019 ± 0.003, 0.027 ± 0.010, 0.033 ± 0.008, 0.032 ± 0.009, and 0.043 ± 0.013, respectively. There was a significant positive correlation between the quantitative motility score and the MV (ρ = 0.531, P < 0.001). The AUROC value for diagnosing a MV of 1 (i.e., adynamic small bowel) was 0.953 (95% confidence interval, 0.923–0.984). Moreover, the optimal cutoff for the quantitative motility score was 0.024, with a sensitivity of 100% (15/15) and specificity of 89.9% (143/159). CONCLUSION: The quantitative motility score calculated from a cine MRI enables diagnosis of an adynamic small bowel, and potentially discerns various degrees of bowel motility. |
format | Online Article Text |
id | pubmed-10613842 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-106138422023-11-01 Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging Choi, Ji Young Yun, Jihye Heo, Subin Kim, Dong Wook Choi, Sang Hyun Yoon, Jiyoung Kim, Kyuwon Jung, Kee Wook Myung, Seung-Jae Korean J Radiol Gastrointestinal Imaging OBJECTIVE: Cine magnetic resonance imaging (MRI) has emerged as a noninvasive method to quantitatively assess bowel motility. However, its accuracy in measuring various degrees of small bowel motility has not been extensively evaluated. We aimed to draw a quantitative small bowel motility score from cine MRI and evaluate its performance in a population with varying degrees of small bowel motility. MATERIALS AND METHODS: A total of 174 participants (28.5 ± 7.6 years; 135 males) underwent a 22-second-long cine MRI sequence (2-dimensional balanced turbo-field echo; 0.5 seconds per image) approximately 5 minutes after being intravenously administered 10 mg of scopolamine-N-butyl bromide to deliberately create diverse degrees of small bowel motility. In a manually segmented area of the small bowel, motility was automatically quantified using a nonrigid registration and calculated as a quantitative motility score. The mean value (MV) of motility grades visually assessed by two radiologists was used as a reference standard. The quantitative motility score’s correlation (Spearman’s ρ) with the reference standard and performance (area under the receiver operating characteristics curve [AUROC], sensitivity, and specificity) for diagnosing adynamic small bowel (MV of 1) were evaluated. RESULTS: For the MV of the quantitative motility scores at grades 1, 1.5, 2, 2.5, and 3, the mean ± standard deviation values were 0.019 ± 0.003, 0.027 ± 0.010, 0.033 ± 0.008, 0.032 ± 0.009, and 0.043 ± 0.013, respectively. There was a significant positive correlation between the quantitative motility score and the MV (ρ = 0.531, P < 0.001). The AUROC value for diagnosing a MV of 1 (i.e., adynamic small bowel) was 0.953 (95% confidence interval, 0.923–0.984). Moreover, the optimal cutoff for the quantitative motility score was 0.024, with a sensitivity of 100% (15/15) and specificity of 89.9% (143/159). CONCLUSION: The quantitative motility score calculated from a cine MRI enables diagnosis of an adynamic small bowel, and potentially discerns various degrees of bowel motility. The Korean Society of Radiology 2023-11 2023-09-14 /pmc/articles/PMC10613842/ /pubmed/37724587 http://dx.doi.org/10.3348/kjr.2023.0144 Text en Copyright © 2023 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Gastrointestinal Imaging Choi, Ji Young Yun, Jihye Heo, Subin Kim, Dong Wook Choi, Sang Hyun Yoon, Jiyoung Kim, Kyuwon Jung, Kee Wook Myung, Seung-Jae Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging |
title | Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging |
title_full | Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging |
title_fullStr | Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging |
title_full_unstemmed | Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging |
title_short | Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging |
title_sort | technical feasibility of quantitative measurement of various degrees of small bowel motility using cine magnetic resonance imaging |
topic | Gastrointestinal Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10613842/ https://www.ncbi.nlm.nih.gov/pubmed/37724587 http://dx.doi.org/10.3348/kjr.2023.0144 |
work_keys_str_mv | AT choijiyoung technicalfeasibilityofquantitativemeasurementofvariousdegreesofsmallbowelmotilityusingcinemagneticresonanceimaging AT yunjihye technicalfeasibilityofquantitativemeasurementofvariousdegreesofsmallbowelmotilityusingcinemagneticresonanceimaging AT heosubin technicalfeasibilityofquantitativemeasurementofvariousdegreesofsmallbowelmotilityusingcinemagneticresonanceimaging AT kimdongwook technicalfeasibilityofquantitativemeasurementofvariousdegreesofsmallbowelmotilityusingcinemagneticresonanceimaging AT choisanghyun technicalfeasibilityofquantitativemeasurementofvariousdegreesofsmallbowelmotilityusingcinemagneticresonanceimaging AT yoonjiyoung technicalfeasibilityofquantitativemeasurementofvariousdegreesofsmallbowelmotilityusingcinemagneticresonanceimaging AT kimkyuwon technicalfeasibilityofquantitativemeasurementofvariousdegreesofsmallbowelmotilityusingcinemagneticresonanceimaging AT jungkeewook technicalfeasibilityofquantitativemeasurementofvariousdegreesofsmallbowelmotilityusingcinemagneticresonanceimaging AT myungseungjae technicalfeasibilityofquantitativemeasurementofvariousdegreesofsmallbowelmotilityusingcinemagneticresonanceimaging |