Bend‐insensitive fiber optic ultrasonic tracking probe for cardiovascular interventions

BACKGROUND: Transesophageal echocardiography (TEE) is widely used to guide medical device placement in minimally invasive cardiovascular procedures. However, visualization of the device tip with TEE can be challenging. Ultrasonic tracking, enabled by an integrated fiber optic ultrasound sensor (FOUS...

Descripción completa

Detalles Bibliográficos
Autores principales: Mathews, Sunish J., Little, Callum, Zhang, Edward, Beard, Paul, Mastracci, Tara, Rakhit, Roby, Desjardins, Adrien E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10615325/
https://www.ncbi.nlm.nih.gov/pubmed/36842082
http://dx.doi.org/10.1002/mp.16334
_version_ 1785129199432892416
author Mathews, Sunish J.
Little, Callum
Zhang, Edward
Beard, Paul
Mastracci, Tara
Rakhit, Roby
Desjardins, Adrien E.
author_facet Mathews, Sunish J.
Little, Callum
Zhang, Edward
Beard, Paul
Mastracci, Tara
Rakhit, Roby
Desjardins, Adrien E.
author_sort Mathews, Sunish J.
collection PubMed
description BACKGROUND: Transesophageal echocardiography (TEE) is widely used to guide medical device placement in minimally invasive cardiovascular procedures. However, visualization of the device tip with TEE can be challenging. Ultrasonic tracking, enabled by an integrated fiber optic ultrasound sensor (FOUS) that receives transmissions from the TEE probe, is very well suited to improving device localization in this context. The problem addressed in this study is that tight deflections of devices such as a steerable guide catheter can result in bending of the FOUS beyond its specifications and a corresponding loss of ultrasound sensitivity. PURPOSE: A bend‐insensitive FOUS was developed, and its utility with ultrasonic tracking of a steerable tip during TEE‐based image guidance was demonstrated. METHODS: Fiberoptic ultrasound sensors were fabricated using both standard and bend insensitive single mode fibers and subjected to static bending at the distal end. The interference transfer function and ultrasound sensitivities were compared for both types of FOUS. The bend‐insensitive FOUS was integrated within a steerable guide catheter, which served as an exemplar device; the signal‐to‐noise ratio (SNR) of tracking signals from the catheter tip with a straight and a fully deflected distal end were measured in a cardiac ultrasound phantom for over 100 frames. RESULTS: With tight bending at the distal end (bend radius < 10 mm), the standard FOUS experienced a complete loss of US sensitivity due to high attenuation in the fiber, whereas the bend‐insensitive FOUS had largely unchanged performance, with a SNR of 47.7 for straight fiber and a SNR of 36.8 at a bend radius of 3.0 mm. When integrated into the steerable guide catheter, the mean SNRs of the ultrasonic tracking signals recorded with the catheter in a cardiac phantom were similar for straight and fully deflected distal ends: 195 and 163. CONCLUSION: The FOUS fabricated from bend‐insensitive fiber overcomes the bend restrictions associated with the FOUS fabricated from standard single mode fiber, thereby enabling its use in ultrasonic tracking in a wide range of cardiovascular devices.
format Online
Article
Text
id pubmed-10615325
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-106153252023-10-31 Bend‐insensitive fiber optic ultrasonic tracking probe for cardiovascular interventions Mathews, Sunish J. Little, Callum Zhang, Edward Beard, Paul Mastracci, Tara Rakhit, Roby Desjardins, Adrien E. Med Phys DIAGNOSTIC IMAGING (IONIZING AND NON‐IONIZING) BACKGROUND: Transesophageal echocardiography (TEE) is widely used to guide medical device placement in minimally invasive cardiovascular procedures. However, visualization of the device tip with TEE can be challenging. Ultrasonic tracking, enabled by an integrated fiber optic ultrasound sensor (FOUS) that receives transmissions from the TEE probe, is very well suited to improving device localization in this context. The problem addressed in this study is that tight deflections of devices such as a steerable guide catheter can result in bending of the FOUS beyond its specifications and a corresponding loss of ultrasound sensitivity. PURPOSE: A bend‐insensitive FOUS was developed, and its utility with ultrasonic tracking of a steerable tip during TEE‐based image guidance was demonstrated. METHODS: Fiberoptic ultrasound sensors were fabricated using both standard and bend insensitive single mode fibers and subjected to static bending at the distal end. The interference transfer function and ultrasound sensitivities were compared for both types of FOUS. The bend‐insensitive FOUS was integrated within a steerable guide catheter, which served as an exemplar device; the signal‐to‐noise ratio (SNR) of tracking signals from the catheter tip with a straight and a fully deflected distal end were measured in a cardiac ultrasound phantom for over 100 frames. RESULTS: With tight bending at the distal end (bend radius < 10 mm), the standard FOUS experienced a complete loss of US sensitivity due to high attenuation in the fiber, whereas the bend‐insensitive FOUS had largely unchanged performance, with a SNR of 47.7 for straight fiber and a SNR of 36.8 at a bend radius of 3.0 mm. When integrated into the steerable guide catheter, the mean SNRs of the ultrasonic tracking signals recorded with the catheter in a cardiac phantom were similar for straight and fully deflected distal ends: 195 and 163. CONCLUSION: The FOUS fabricated from bend‐insensitive fiber overcomes the bend restrictions associated with the FOUS fabricated from standard single mode fiber, thereby enabling its use in ultrasonic tracking in a wide range of cardiovascular devices. John Wiley and Sons Inc. 2023-03-09 2023-06 /pmc/articles/PMC10615325/ /pubmed/36842082 http://dx.doi.org/10.1002/mp.16334 Text en © 2023 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle DIAGNOSTIC IMAGING (IONIZING AND NON‐IONIZING)
Mathews, Sunish J.
Little, Callum
Zhang, Edward
Beard, Paul
Mastracci, Tara
Rakhit, Roby
Desjardins, Adrien E.
Bend‐insensitive fiber optic ultrasonic tracking probe for cardiovascular interventions
title Bend‐insensitive fiber optic ultrasonic tracking probe for cardiovascular interventions
title_full Bend‐insensitive fiber optic ultrasonic tracking probe for cardiovascular interventions
title_fullStr Bend‐insensitive fiber optic ultrasonic tracking probe for cardiovascular interventions
title_full_unstemmed Bend‐insensitive fiber optic ultrasonic tracking probe for cardiovascular interventions
title_short Bend‐insensitive fiber optic ultrasonic tracking probe for cardiovascular interventions
title_sort bend‐insensitive fiber optic ultrasonic tracking probe for cardiovascular interventions
topic DIAGNOSTIC IMAGING (IONIZING AND NON‐IONIZING)
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10615325/
https://www.ncbi.nlm.nih.gov/pubmed/36842082
http://dx.doi.org/10.1002/mp.16334
work_keys_str_mv AT mathewssunishj bendinsensitivefiberopticultrasonictrackingprobeforcardiovascularinterventions
AT littlecallum bendinsensitivefiberopticultrasonictrackingprobeforcardiovascularinterventions
AT zhangedward bendinsensitivefiberopticultrasonictrackingprobeforcardiovascularinterventions
AT beardpaul bendinsensitivefiberopticultrasonictrackingprobeforcardiovascularinterventions
AT mastraccitara bendinsensitivefiberopticultrasonictrackingprobeforcardiovascularinterventions
AT rakhitroby bendinsensitivefiberopticultrasonictrackingprobeforcardiovascularinterventions
AT desjardinsadriene bendinsensitivefiberopticultrasonictrackingprobeforcardiovascularinterventions