Utilization of spontaneous breathing trial, objective cough test, and diaphragmatic ultrasound results to predict extubation success: COBRE-US trial
BACKGROUND: The results of clinical and weaning readiness tests and the spontaneous breathing trial (SBT) are used to predict the success of the weaning process and extubation. METHODS: We evaluated the capacity of the cuff leak test, rate of rapid and shallow breathing, cough intensity, and diaphra...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10617213/ https://www.ncbi.nlm.nih.gov/pubmed/37908002 http://dx.doi.org/10.1186/s13054-023-04708-y |
Sumario: | BACKGROUND: The results of clinical and weaning readiness tests and the spontaneous breathing trial (SBT) are used to predict the success of the weaning process and extubation. METHODS: We evaluated the capacity of the cuff leak test, rate of rapid and shallow breathing, cough intensity, and diaphragmatic contraction velocity (DCV) to predict the success of the SBT and extubation in a prospective, multicenter observational study with consecutive adult patients admitted to four intensive care units. We used receiver operating characteristic (ROC) curves to assess the tests’ predictive capacity and built predictive models using logistic regression. RESULTS: We recruited 367 subjects who were receiving invasive mechanical ventilation and on whom 456 SBTs were performed, with a success rate of 76.5%. To predict the success of the SBT, we derived the following equation: (0.56 × Cough) − (0.13 × DCV) + 0.25. When the cutoff point was ≥ 0.83, the sensitivity was 91.5%, the specificity was 22.1%, and the overall accuracy was 76.2%. The area under the ROC curve (AUC-ROC) was 0.63. To predict extubation success, we derived the following equation: (5.7 × SBT) + (0.75 × Cough) − (0.25 × DCV) − 4.5. When the cutoff point was ≥ 1.25, the sensitivity was 96.8%, the specificity was 78.4%, and the overall accuracy was 91.5%. The AUC-ROC of this model was 0.91. CONCLUSION: Objective measurement of cough and diaphragmatic contraction velocity could be used to predict SBT success. The equation for predicting successful extubation, which includes SBT, cough, and diaphragmatic contraction velocity values, showed excellent discriminative capacity. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13054-023-04708-y. |
---|