Cargando…
Reliability and validity of impact absorption rate using accelerometers during single-leg drop-jump landings
[Purpose] To assess the reliability and validity of accelerometer-based impact absorption rate measurements during single-leg drop-jump landings. [Participants and Methods] Study participants were healthy adult males. The task involved a single-leg drop-jump from the platform with a forward landing...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Society of Physical Therapy Science
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10618021/ https://www.ncbi.nlm.nih.gov/pubmed/37915453 http://dx.doi.org/10.1589/jpts.35.714 |
_version_ | 1785129690623639552 |
---|---|
author | Kurihara, Yasushi Ohsugi, Hironori Karasuno, Hiroshi Matsuda, Tadamitsu Matsumura, Masashi |
author_facet | Kurihara, Yasushi Ohsugi, Hironori Karasuno, Hiroshi Matsuda, Tadamitsu Matsumura, Masashi |
author_sort | Kurihara, Yasushi |
collection | PubMed |
description | [Purpose] To assess the reliability and validity of accelerometer-based impact absorption rate measurements during single-leg drop-jump landings. [Participants and Methods] Study participants were healthy adult males. The task involved a single-leg drop-jump from the platform with a forward landing onto a floor reaction force plate. Accelerometers were fastened to the trunk, while foot switches were attached to the forefoot plantar surfaces. The impact absorption rate was calculated as the peak composite acceleration during the single-leg drop-jump landing divided by the duration from foot contact to the attainment of peak value. The loading rate (LR) was calculated by dividing the peak vertical force by the duration from foot contact to the attainment of peak value, leveraging the data obtained from a floor reaction force plate. Intraclass correlation coefficients (ICC) were used for intra- and inter-rater reliability analyses of 18 and 12 participants, respectively. The validity was examined through the correlation between impact absorption rate and LR in the 18 participants. [Results] The intra- (ICC (1,1)) and inter-rater (ICC (2,1)) reliabilities for the impact absorption rates were 0.89 and 0.88, respectively. A significant positive correlation was observed between impact absorption rates and LR (r=0.71). [Conclusion] The impact absorption rate may be valuable in clinical practice. |
format | Online Article Text |
id | pubmed-10618021 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Society of Physical Therapy Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-106180212023-11-01 Reliability and validity of impact absorption rate using accelerometers during single-leg drop-jump landings Kurihara, Yasushi Ohsugi, Hironori Karasuno, Hiroshi Matsuda, Tadamitsu Matsumura, Masashi J Phys Ther Sci Original Article [Purpose] To assess the reliability and validity of accelerometer-based impact absorption rate measurements during single-leg drop-jump landings. [Participants and Methods] Study participants were healthy adult males. The task involved a single-leg drop-jump from the platform with a forward landing onto a floor reaction force plate. Accelerometers were fastened to the trunk, while foot switches were attached to the forefoot plantar surfaces. The impact absorption rate was calculated as the peak composite acceleration during the single-leg drop-jump landing divided by the duration from foot contact to the attainment of peak value. The loading rate (LR) was calculated by dividing the peak vertical force by the duration from foot contact to the attainment of peak value, leveraging the data obtained from a floor reaction force plate. Intraclass correlation coefficients (ICC) were used for intra- and inter-rater reliability analyses of 18 and 12 participants, respectively. The validity was examined through the correlation between impact absorption rate and LR in the 18 participants. [Results] The intra- (ICC (1,1)) and inter-rater (ICC (2,1)) reliabilities for the impact absorption rates were 0.89 and 0.88, respectively. A significant positive correlation was observed between impact absorption rates and LR (r=0.71). [Conclusion] The impact absorption rate may be valuable in clinical practice. The Society of Physical Therapy Science 2023-11-01 2023-11 /pmc/articles/PMC10618021/ /pubmed/37915453 http://dx.doi.org/10.1589/jpts.35.714 Text en 2023©by the Society of Physical Therapy Science. Published by IPEC Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. (CC-BY-NC-ND 4.0: https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Original Article Kurihara, Yasushi Ohsugi, Hironori Karasuno, Hiroshi Matsuda, Tadamitsu Matsumura, Masashi Reliability and validity of impact absorption rate using accelerometers during single-leg drop-jump landings |
title | Reliability and validity of impact absorption rate using accelerometers during single-leg drop-jump landings |
title_full | Reliability and validity of impact absorption rate using accelerometers during single-leg drop-jump landings |
title_fullStr | Reliability and validity of impact absorption rate using accelerometers during single-leg drop-jump landings |
title_full_unstemmed | Reliability and validity of impact absorption rate using accelerometers during single-leg drop-jump landings |
title_short | Reliability and validity of impact absorption rate using accelerometers during single-leg drop-jump landings |
title_sort | reliability and validity of impact absorption rate using accelerometers during single-leg drop-jump landings |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10618021/ https://www.ncbi.nlm.nih.gov/pubmed/37915453 http://dx.doi.org/10.1589/jpts.35.714 |
work_keys_str_mv | AT kuriharayasushi reliabilityandvalidityofimpactabsorptionrateusingaccelerometersduringsinglelegdropjumplandings AT ohsugihironori reliabilityandvalidityofimpactabsorptionrateusingaccelerometersduringsinglelegdropjumplandings AT karasunohiroshi reliabilityandvalidityofimpactabsorptionrateusingaccelerometersduringsinglelegdropjumplandings AT matsudatadamitsu reliabilityandvalidityofimpactabsorptionrateusingaccelerometersduringsinglelegdropjumplandings AT matsumuramasashi reliabilityandvalidityofimpactabsorptionrateusingaccelerometersduringsinglelegdropjumplandings |