Cargando…

Discrepancies in tumor mutation burden reporting from sequential endobronchial ultrasound transbronchial needle aspiration samples within single lymph node stations - brief report

INTRODUCTION: Tumour Mutation Burden (TMB) is a potential biomarker for immune cancer therapies. Here we investigated parameters that might affect TMB using duplicate cytology smears obtained from endobronchial ultrasound transbronchial needle aspiration (EBUS TBNA)-sampled malignant lymph nodes. ME...

Descripción completa

Detalles Bibliográficos
Autores principales: Fielding, David, Dalley, Andrew J., Singh, Mahendra, Nandakumar, Lakshmy, Lakis, Vanessa, Chittoory, Haarika, Fairbairn, David, Patch, Ann-Marie, Kazakoff, Stephen H., Ferguson, Kaltin, Bashirzadeh, Farzad, Bint, Michael, Pahoff, Carl, Son, Jung Hwa, Ryan, Kimberley, Hodgson, Alan, Sharma, Sowmya, Pearson, John V., Waddell, Nicola, Lakhani, Sunil R., Hartel, Gunter, Simpson, Peter T., Nones, Katia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10620689/
https://www.ncbi.nlm.nih.gov/pubmed/37927461
http://dx.doi.org/10.3389/fonc.2023.1259882
_version_ 1785130254745993216
author Fielding, David
Dalley, Andrew J.
Singh, Mahendra
Nandakumar, Lakshmy
Lakis, Vanessa
Chittoory, Haarika
Fairbairn, David
Patch, Ann-Marie
Kazakoff, Stephen H.
Ferguson, Kaltin
Bashirzadeh, Farzad
Bint, Michael
Pahoff, Carl
Son, Jung Hwa
Ryan, Kimberley
Hodgson, Alan
Sharma, Sowmya
Pearson, John V.
Waddell, Nicola
Lakhani, Sunil R.
Hartel, Gunter
Simpson, Peter T.
Nones, Katia
author_facet Fielding, David
Dalley, Andrew J.
Singh, Mahendra
Nandakumar, Lakshmy
Lakis, Vanessa
Chittoory, Haarika
Fairbairn, David
Patch, Ann-Marie
Kazakoff, Stephen H.
Ferguson, Kaltin
Bashirzadeh, Farzad
Bint, Michael
Pahoff, Carl
Son, Jung Hwa
Ryan, Kimberley
Hodgson, Alan
Sharma, Sowmya
Pearson, John V.
Waddell, Nicola
Lakhani, Sunil R.
Hartel, Gunter
Simpson, Peter T.
Nones, Katia
author_sort Fielding, David
collection PubMed
description INTRODUCTION: Tumour Mutation Burden (TMB) is a potential biomarker for immune cancer therapies. Here we investigated parameters that might affect TMB using duplicate cytology smears obtained from endobronchial ultrasound transbronchial needle aspiration (EBUS TBNA)-sampled malignant lymph nodes. METHODS: Individual Diff-Quik cytology smears were prepared for each needle pass. DNA extracted from each smear underwent sequencing using large gene panel (TruSight Oncology 500 (TSO500 - Illumina)). TMB was estimated using the TSO500 Local App v. 2.0 (Illumina). RESULTS: Twenty patients had two or more Diff-Quik smears (total 45 smears) which passed sequencing quality control. Average smear TMB was 8.7 ± 5.0 mutations per megabase (Mb). Sixteen of the 20 patients had paired samples with minimal differences in TMB score (average difference 1.3 ± 0.85). Paired samples from 13 patients had concordant TMB (scores below or above a threshold of 10 mutations/Mb). Markedly discrepant TMB was observed in four cases, with an average difference of 11.3 ± 2.7 mutations/Mb. Factors affecting TMB calling included sample tumour content, the amount of DNA used in sequencing, and bone fide heterogeneity of node tumour between paired samples. CONCLUSION: TMB assessment is feasible from EBUS-TBNA smears from a single needle pass. Repeated samples of a lymph node station have minimal variation in TMB in most cases. However, this novel data shows how tumour content and minor change in site of node sampling can impact TMB. Further study is needed on whether all node aspirates should be combined in 1 sample, or whether testing independent nodes using smears is needed.
format Online
Article
Text
id pubmed-10620689
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-106206892023-11-03 Discrepancies in tumor mutation burden reporting from sequential endobronchial ultrasound transbronchial needle aspiration samples within single lymph node stations - brief report Fielding, David Dalley, Andrew J. Singh, Mahendra Nandakumar, Lakshmy Lakis, Vanessa Chittoory, Haarika Fairbairn, David Patch, Ann-Marie Kazakoff, Stephen H. Ferguson, Kaltin Bashirzadeh, Farzad Bint, Michael Pahoff, Carl Son, Jung Hwa Ryan, Kimberley Hodgson, Alan Sharma, Sowmya Pearson, John V. Waddell, Nicola Lakhani, Sunil R. Hartel, Gunter Simpson, Peter T. Nones, Katia Front Oncol Oncology INTRODUCTION: Tumour Mutation Burden (TMB) is a potential biomarker for immune cancer therapies. Here we investigated parameters that might affect TMB using duplicate cytology smears obtained from endobronchial ultrasound transbronchial needle aspiration (EBUS TBNA)-sampled malignant lymph nodes. METHODS: Individual Diff-Quik cytology smears were prepared for each needle pass. DNA extracted from each smear underwent sequencing using large gene panel (TruSight Oncology 500 (TSO500 - Illumina)). TMB was estimated using the TSO500 Local App v. 2.0 (Illumina). RESULTS: Twenty patients had two or more Diff-Quik smears (total 45 smears) which passed sequencing quality control. Average smear TMB was 8.7 ± 5.0 mutations per megabase (Mb). Sixteen of the 20 patients had paired samples with minimal differences in TMB score (average difference 1.3 ± 0.85). Paired samples from 13 patients had concordant TMB (scores below or above a threshold of 10 mutations/Mb). Markedly discrepant TMB was observed in four cases, with an average difference of 11.3 ± 2.7 mutations/Mb. Factors affecting TMB calling included sample tumour content, the amount of DNA used in sequencing, and bone fide heterogeneity of node tumour between paired samples. CONCLUSION: TMB assessment is feasible from EBUS-TBNA smears from a single needle pass. Repeated samples of a lymph node station have minimal variation in TMB in most cases. However, this novel data shows how tumour content and minor change in site of node sampling can impact TMB. Further study is needed on whether all node aspirates should be combined in 1 sample, or whether testing independent nodes using smears is needed. Frontiers Media S.A. 2023-10-19 /pmc/articles/PMC10620689/ /pubmed/37927461 http://dx.doi.org/10.3389/fonc.2023.1259882 Text en Copyright © 2023 Fielding, Dalley, Singh, Nandakumar, Lakis, Chittoory, Fairbairn, Patch, Kazakoff, Ferguson, Bashirzadeh, Bint, Pahoff, Son, Ryan, Hodgson, Sharma, Pearson, Waddell, Lakhani, Hartel, Simpson and Nones https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Fielding, David
Dalley, Andrew J.
Singh, Mahendra
Nandakumar, Lakshmy
Lakis, Vanessa
Chittoory, Haarika
Fairbairn, David
Patch, Ann-Marie
Kazakoff, Stephen H.
Ferguson, Kaltin
Bashirzadeh, Farzad
Bint, Michael
Pahoff, Carl
Son, Jung Hwa
Ryan, Kimberley
Hodgson, Alan
Sharma, Sowmya
Pearson, John V.
Waddell, Nicola
Lakhani, Sunil R.
Hartel, Gunter
Simpson, Peter T.
Nones, Katia
Discrepancies in tumor mutation burden reporting from sequential endobronchial ultrasound transbronchial needle aspiration samples within single lymph node stations - brief report
title Discrepancies in tumor mutation burden reporting from sequential endobronchial ultrasound transbronchial needle aspiration samples within single lymph node stations - brief report
title_full Discrepancies in tumor mutation burden reporting from sequential endobronchial ultrasound transbronchial needle aspiration samples within single lymph node stations - brief report
title_fullStr Discrepancies in tumor mutation burden reporting from sequential endobronchial ultrasound transbronchial needle aspiration samples within single lymph node stations - brief report
title_full_unstemmed Discrepancies in tumor mutation burden reporting from sequential endobronchial ultrasound transbronchial needle aspiration samples within single lymph node stations - brief report
title_short Discrepancies in tumor mutation burden reporting from sequential endobronchial ultrasound transbronchial needle aspiration samples within single lymph node stations - brief report
title_sort discrepancies in tumor mutation burden reporting from sequential endobronchial ultrasound transbronchial needle aspiration samples within single lymph node stations - brief report
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10620689/
https://www.ncbi.nlm.nih.gov/pubmed/37927461
http://dx.doi.org/10.3389/fonc.2023.1259882
work_keys_str_mv AT fieldingdavid discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT dalleyandrewj discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT singhmahendra discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT nandakumarlakshmy discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT lakisvanessa discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT chittooryhaarika discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT fairbairndavid discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT patchannmarie discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT kazakoffstephenh discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT fergusonkaltin discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT bashirzadehfarzad discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT bintmichael discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT pahoffcarl discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT sonjunghwa discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT ryankimberley discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT hodgsonalan discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT sharmasowmya discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT pearsonjohnv discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT waddellnicola discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT lakhanisunilr discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT hartelgunter discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT simpsonpetert discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport
AT noneskatia discrepanciesintumormutationburdenreportingfromsequentialendobronchialultrasoundtransbronchialneedleaspirationsampleswithinsinglelymphnodestationsbriefreport