Cargando…
Development of a novel delivery quality assurance system based on simultaneous verification of dose distribution and binary multi-leaf collimator opening in helical tomotherapy
BACKGROUND: Intensity-modulated radiation therapy (IMRT) requires delivery quality assurance (DQA) to ensure treatment accuracy and safety. Irradiation techniques such as helical tomotherapy (HT) have become increasingly complex, rendering conventional verification methods insufficient. This study a...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10621123/ https://www.ncbi.nlm.nih.gov/pubmed/37919745 http://dx.doi.org/10.1186/s13014-023-02366-6 |
_version_ | 1785130347406557184 |
---|---|
author | Tanaka, Yuichi Hashimoto, Masatoshi Ishigami, Minoru Nakano, Masahiro Hasegawa, Tomoyuki |
author_facet | Tanaka, Yuichi Hashimoto, Masatoshi Ishigami, Minoru Nakano, Masahiro Hasegawa, Tomoyuki |
author_sort | Tanaka, Yuichi |
collection | PubMed |
description | BACKGROUND: Intensity-modulated radiation therapy (IMRT) requires delivery quality assurance (DQA) to ensure treatment accuracy and safety. Irradiation techniques such as helical tomotherapy (HT) have become increasingly complex, rendering conventional verification methods insufficient. This study aims to develop a novel DQA system to simultaneously verify dose distribution and multi-leaf collimator (MLC) opening during HT. METHODS: We developed a prototype detector consisting of a cylindrical plastic scintillator (PS) and a cooled charge-coupled device (CCD) camera. Scintillation light was recorded using a CCD camera. A TomoHDA (Accuray Inc.) was used as the irradiation device. The characteristics of the developed system were evaluated based on the light intensity. The IMRT plan was irradiated onto the PS to record a moving image of the scintillation light. MLC opening and light distribution were obtained from the recorded images. To detect MLC opening, we placed a region of interest (ROI) on the image, corresponding to the leaf position, and analyzed the temporal change in the light intensity within each ROI. Corrections were made for light changes due to differences in the PS shape and irradiation position. The corrected light intensity was converted into the leaf opening time (LOT), and an MLC sinogram was constructed. The reconstructed MLC sinogram was compared with that calculated using the treatment planning system (TPS). Light distribution was obtained by integrating all frames obtained during IMRT irradiation. The light distribution was compared with the dose distribution calculated using the TPS. RESULTS: The LOT and the light intensity followed a linear relationship. Owing to MLC movements, the sensitivity and specificity of the reconstructed sinogram exceeded 97%, with an LOT error of − 3.9 ± 7.8%. The light distribution pattern closely resembled that of the dose distribution. The average dose difference and the pass rate of gamma analysis with 3%/3 mm were 1.4 ± 0.2% and 99%, respectively. CONCLUSION: We developed a DQA system for simultaneous and accurate verification of both dose distribution and MLC opening during HT. |
format | Online Article Text |
id | pubmed-10621123 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-106211232023-11-03 Development of a novel delivery quality assurance system based on simultaneous verification of dose distribution and binary multi-leaf collimator opening in helical tomotherapy Tanaka, Yuichi Hashimoto, Masatoshi Ishigami, Minoru Nakano, Masahiro Hasegawa, Tomoyuki Radiat Oncol Research BACKGROUND: Intensity-modulated radiation therapy (IMRT) requires delivery quality assurance (DQA) to ensure treatment accuracy and safety. Irradiation techniques such as helical tomotherapy (HT) have become increasingly complex, rendering conventional verification methods insufficient. This study aims to develop a novel DQA system to simultaneously verify dose distribution and multi-leaf collimator (MLC) opening during HT. METHODS: We developed a prototype detector consisting of a cylindrical plastic scintillator (PS) and a cooled charge-coupled device (CCD) camera. Scintillation light was recorded using a CCD camera. A TomoHDA (Accuray Inc.) was used as the irradiation device. The characteristics of the developed system were evaluated based on the light intensity. The IMRT plan was irradiated onto the PS to record a moving image of the scintillation light. MLC opening and light distribution were obtained from the recorded images. To detect MLC opening, we placed a region of interest (ROI) on the image, corresponding to the leaf position, and analyzed the temporal change in the light intensity within each ROI. Corrections were made for light changes due to differences in the PS shape and irradiation position. The corrected light intensity was converted into the leaf opening time (LOT), and an MLC sinogram was constructed. The reconstructed MLC sinogram was compared with that calculated using the treatment planning system (TPS). Light distribution was obtained by integrating all frames obtained during IMRT irradiation. The light distribution was compared with the dose distribution calculated using the TPS. RESULTS: The LOT and the light intensity followed a linear relationship. Owing to MLC movements, the sensitivity and specificity of the reconstructed sinogram exceeded 97%, with an LOT error of − 3.9 ± 7.8%. The light distribution pattern closely resembled that of the dose distribution. The average dose difference and the pass rate of gamma analysis with 3%/3 mm were 1.4 ± 0.2% and 99%, respectively. CONCLUSION: We developed a DQA system for simultaneous and accurate verification of both dose distribution and MLC opening during HT. BioMed Central 2023-11-02 /pmc/articles/PMC10621123/ /pubmed/37919745 http://dx.doi.org/10.1186/s13014-023-02366-6 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Tanaka, Yuichi Hashimoto, Masatoshi Ishigami, Minoru Nakano, Masahiro Hasegawa, Tomoyuki Development of a novel delivery quality assurance system based on simultaneous verification of dose distribution and binary multi-leaf collimator opening in helical tomotherapy |
title | Development of a novel delivery quality assurance system based on simultaneous verification of dose distribution and binary multi-leaf collimator opening in helical tomotherapy |
title_full | Development of a novel delivery quality assurance system based on simultaneous verification of dose distribution and binary multi-leaf collimator opening in helical tomotherapy |
title_fullStr | Development of a novel delivery quality assurance system based on simultaneous verification of dose distribution and binary multi-leaf collimator opening in helical tomotherapy |
title_full_unstemmed | Development of a novel delivery quality assurance system based on simultaneous verification of dose distribution and binary multi-leaf collimator opening in helical tomotherapy |
title_short | Development of a novel delivery quality assurance system based on simultaneous verification of dose distribution and binary multi-leaf collimator opening in helical tomotherapy |
title_sort | development of a novel delivery quality assurance system based on simultaneous verification of dose distribution and binary multi-leaf collimator opening in helical tomotherapy |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10621123/ https://www.ncbi.nlm.nih.gov/pubmed/37919745 http://dx.doi.org/10.1186/s13014-023-02366-6 |
work_keys_str_mv | AT tanakayuichi developmentofanoveldeliveryqualityassurancesystembasedonsimultaneousverificationofdosedistributionandbinarymultileafcollimatoropeninginhelicaltomotherapy AT hashimotomasatoshi developmentofanoveldeliveryqualityassurancesystembasedonsimultaneousverificationofdosedistributionandbinarymultileafcollimatoropeninginhelicaltomotherapy AT ishigamiminoru developmentofanoveldeliveryqualityassurancesystembasedonsimultaneousverificationofdosedistributionandbinarymultileafcollimatoropeninginhelicaltomotherapy AT nakanomasahiro developmentofanoveldeliveryqualityassurancesystembasedonsimultaneousverificationofdosedistributionandbinarymultileafcollimatoropeninginhelicaltomotherapy AT hasegawatomoyuki developmentofanoveldeliveryqualityassurancesystembasedonsimultaneousverificationofdosedistributionandbinarymultileafcollimatoropeninginhelicaltomotherapy |