Cargando…

Robotic arm-assisted unicondylar knee arthroplasty resulted in superior radiological accuracy: a propensity score-matched analysis

INTRODUCTION: Unicompartmental knee arthroplasty (UKA) is an effective surgical treatment for medial compartment arthritis of the knee, yet surgical outcomes are directly related to surgical execution. Robotic arm-assisted surgery aims to address these difficulties by allowing for detailed preoperat...

Descripción completa

Detalles Bibliográficos
Autores principales: Yeung, Matthew H. Y., Fu, Henry, Cheung, Amy, Kwan, Vincent Chan Wai, Cheung, Man Hong, Chan, Ping Keung, Chiu, Kwong Yuen, Yan, Chun Hoi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10621242/
https://www.ncbi.nlm.nih.gov/pubmed/37915082
http://dx.doi.org/10.1186/s42836-023-00210-6
Descripción
Sumario:INTRODUCTION: Unicompartmental knee arthroplasty (UKA) is an effective surgical treatment for medial compartment arthritis of the knee, yet surgical outcomes are directly related to surgical execution. Robotic arm-assisted surgery aims to address these difficulties by allowing for detailed preoperative planning, real-time intraoperative assessment and haptic-controlled bone removal. This study aimed to compare the clinical and radiological outcomes between conventional manual mobile bearing and robot arm-assisted fixed bearing medial UKA in our local population. MATERIALS AND METHODS: This is a retrospective case–control study of 148 UKAs performed at an academic institution with a minimum of 1-year follow-up. 74 robotic arm-assisted UKAs were matched to 74 conventional UKAs via propensity score matching. Radiological outcomes included postoperative mechanical axis and individual component alignment. Clinical parameters included a range of motion, Knee Society knee score and functional assessment taken before, 6 and 12 months after the operation. RESULTS: Robot arm-assisted UKA produced a more neutral component coronal alignment in both femoral component (robotic -0.2 ± 2.8, manual 2.6 ± 2.3; P = 0.043) and tibial component (robotic -0.3 ± 4.0, manual 1.7 ± 5.3; P < 0.001). While the postoperative mechanical axis was comparable, robot arm-assisted UKA demonstrated a smaller posterior tibial slope (robotic 5.7 ± 2.7, manual 8.2 ± 3.3; P = 0.02). Clinical outcomes did not show any statistically significant differences. CONCLUSION: Compared with conventional UKA, robotic arm-assisted UKA demonstrated improved component alignment and comparable clinical outcomes. Improved radiological accuracy with robotic-arm assistance demonstrated promising early results.