Cargando…

Investigation of Platelet Function Analyzer 200 platelet function measurements in healthy cats and cats receiving clopidogrel

The Platelet Function Analyzer 200 (PFA-200; Siemens) is an in vitro substitute for in vivo bleeding time that is designed to investigate platelet function in a more physiologic manner than traditional aggregometry. The analyzer reports a closure time (CT) as a marker of platelet function, and may a...

Descripción completa

Detalles Bibliográficos
Autores principales: Kornya, Matthew R., Abrams-Ogg, Anthony C. G., Blois, Shauna L., Wood, R. Darren
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10621536/
https://www.ncbi.nlm.nih.gov/pubmed/37646490
http://dx.doi.org/10.1177/10406387231197440
_version_ 1785130394304118784
author Kornya, Matthew R.
Abrams-Ogg, Anthony C. G.
Blois, Shauna L.
Wood, R. Darren
author_facet Kornya, Matthew R.
Abrams-Ogg, Anthony C. G.
Blois, Shauna L.
Wood, R. Darren
author_sort Kornya, Matthew R.
collection PubMed
description The Platelet Function Analyzer 200 (PFA-200; Siemens) is an in vitro substitute for in vivo bleeding time that is designed to investigate platelet function in a more physiologic manner than traditional aggregometry. The analyzer reports a closure time (CT) as a marker of platelet function, and may also report the calculated platelet function measurement primary hemostasis components, PHC1 and PHC2. These incorporate the measured total volume (TV) of blood aspirated and the initial flow rate (IF). We determined, for the COL/ADP and P2Y cartridges, the median total volume (TV(median)), and RIs for CT, IF, TV, PHC1, and PHC2, and investigated the sensitivity and specificity of those parameters at the determined interpretation thresholds in determination of the clopidogrel effect. Healthy client-owned cats were recruited prospectively to determine RIs for CT, IF, TV, PHC1, and PHC2. Healthy blood-donor cats and cats on clopidogrel therapy were included retrospectively to determine test performance. In 20 healthy cats, RIs for COL/ADP were CT (19.5–87.2 s), IF (199–278 µL/min), TV (199–332 µL), PHC1 (94–106%), and PHC2 (52–148%); and for P2Y, CT (4.2–94.3 s), IF (112–208 µL/min), TV (151–294 µL), PHC1 (35–178%), and PHC2 (90–109%). CVs were calculated for all of these values. Specificity for detection of the clopidogrel effect was calculated from a group of healthy blood donors, and sensitivity for detection of the clopidogrel effect from a group of cats with known clopidogrel effect. Sensitivity and specificity were, for COL/ADP: CT (83.3%, 66.6%), IF (41.4%, 83.3%), TV (83.3%, 100%), PHC1 (100%, 100%) and PHC2 (100%, 83.3%); and for P2Y: CT (100%, 94.4%), IF (30%, 44.4%), TV (100%, 94.4%), PHC1 (100%, 100%), and PHC2 (100%, 97.7%). These PFA-200 values may be beneficial in the determination of platelet function in cats.
format Online
Article
Text
id pubmed-10621536
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-106215362023-11-03 Investigation of Platelet Function Analyzer 200 platelet function measurements in healthy cats and cats receiving clopidogrel Kornya, Matthew R. Abrams-Ogg, Anthony C. G. Blois, Shauna L. Wood, R. Darren J Vet Diagn Invest Full Scientific Reports The Platelet Function Analyzer 200 (PFA-200; Siemens) is an in vitro substitute for in vivo bleeding time that is designed to investigate platelet function in a more physiologic manner than traditional aggregometry. The analyzer reports a closure time (CT) as a marker of platelet function, and may also report the calculated platelet function measurement primary hemostasis components, PHC1 and PHC2. These incorporate the measured total volume (TV) of blood aspirated and the initial flow rate (IF). We determined, for the COL/ADP and P2Y cartridges, the median total volume (TV(median)), and RIs for CT, IF, TV, PHC1, and PHC2, and investigated the sensitivity and specificity of those parameters at the determined interpretation thresholds in determination of the clopidogrel effect. Healthy client-owned cats were recruited prospectively to determine RIs for CT, IF, TV, PHC1, and PHC2. Healthy blood-donor cats and cats on clopidogrel therapy were included retrospectively to determine test performance. In 20 healthy cats, RIs for COL/ADP were CT (19.5–87.2 s), IF (199–278 µL/min), TV (199–332 µL), PHC1 (94–106%), and PHC2 (52–148%); and for P2Y, CT (4.2–94.3 s), IF (112–208 µL/min), TV (151–294 µL), PHC1 (35–178%), and PHC2 (90–109%). CVs were calculated for all of these values. Specificity for detection of the clopidogrel effect was calculated from a group of healthy blood donors, and sensitivity for detection of the clopidogrel effect from a group of cats with known clopidogrel effect. Sensitivity and specificity were, for COL/ADP: CT (83.3%, 66.6%), IF (41.4%, 83.3%), TV (83.3%, 100%), PHC1 (100%, 100%) and PHC2 (100%, 83.3%); and for P2Y: CT (100%, 94.4%), IF (30%, 44.4%), TV (100%, 94.4%), PHC1 (100%, 100%), and PHC2 (100%, 97.7%). These PFA-200 values may be beneficial in the determination of platelet function in cats. SAGE Publications 2023-08-30 2023-11 /pmc/articles/PMC10621536/ /pubmed/37646490 http://dx.doi.org/10.1177/10406387231197440 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Full Scientific Reports
Kornya, Matthew R.
Abrams-Ogg, Anthony C. G.
Blois, Shauna L.
Wood, R. Darren
Investigation of Platelet Function Analyzer 200 platelet function measurements in healthy cats and cats receiving clopidogrel
title Investigation of Platelet Function Analyzer 200 platelet function measurements in healthy cats and cats receiving clopidogrel
title_full Investigation of Platelet Function Analyzer 200 platelet function measurements in healthy cats and cats receiving clopidogrel
title_fullStr Investigation of Platelet Function Analyzer 200 platelet function measurements in healthy cats and cats receiving clopidogrel
title_full_unstemmed Investigation of Platelet Function Analyzer 200 platelet function measurements in healthy cats and cats receiving clopidogrel
title_short Investigation of Platelet Function Analyzer 200 platelet function measurements in healthy cats and cats receiving clopidogrel
title_sort investigation of platelet function analyzer 200 platelet function measurements in healthy cats and cats receiving clopidogrel
topic Full Scientific Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10621536/
https://www.ncbi.nlm.nih.gov/pubmed/37646490
http://dx.doi.org/10.1177/10406387231197440
work_keys_str_mv AT kornyamatthewr investigationofplateletfunctionanalyzer200plateletfunctionmeasurementsinhealthycatsandcatsreceivingclopidogrel
AT abramsogganthonycg investigationofplateletfunctionanalyzer200plateletfunctionmeasurementsinhealthycatsandcatsreceivingclopidogrel
AT bloisshaunal investigationofplateletfunctionanalyzer200plateletfunctionmeasurementsinhealthycatsandcatsreceivingclopidogrel
AT woodrdarren investigationofplateletfunctionanalyzer200plateletfunctionmeasurementsinhealthycatsandcatsreceivingclopidogrel