The Impact of Electromagnetic Interference from Charging All-electric Vehicles on Implantable Cardioverter-defibrillator Performance
Electric vehicles (EVs) are growing in popularity and in general use. The effect of electromagnetic interference (EMI) caused by supercharging all-electric vehicles on implantable cardioverter-defibrillator (ICD) function has not been studied. The objective of this study was to determine the extent...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MediaSphere Medical
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10621619/ https://www.ncbi.nlm.nih.gov/pubmed/37927392 http://dx.doi.org/10.19102/icrm.2023.14102 |
_version_ | 1785130405679071232 |
---|---|
author | Wase, Abdul Hussain, Umbreen Azmat Ratajczak, Theresa Aung, Thein Tun Ali, Omair Markert, Ronald J. |
author_facet | Wase, Abdul Hussain, Umbreen Azmat Ratajczak, Theresa Aung, Thein Tun Ali, Omair Markert, Ronald J. |
author_sort | Wase, Abdul |
collection | PubMed |
description | Electric vehicles (EVs) are growing in popularity and in general use. The effect of electromagnetic interference (EMI) caused by supercharging all-electric vehicles on implantable cardioverter-defibrillator (ICD) function has not been studied. The objective of this study was to determine the extent of the effect of EMI from charging Tesla all-electric vehicles (Tesla, Inc., Austin, TX, USA) on cardiac implantable electronic device function. A proof-of-concept study was performed to explore the potential effect of EMI from Tesla vehicles while charging the battery using a 220-V wall charger and a 480-V Supercharger. Tesla Model S and Model X vehicles were used for this study. We enrolled 34 patients with stable ICD function for the initial phase using the standard wall charger, followed by an additional 35 patients for the second phase using the Supercharger. Tracings were obtained at nominal and highest sensitivity settings while patients sat in the driver’s seat, passenger seat, back seats, and facing the charging port. In each position, the device and the patient were monitored in real time by a certified technician for any inappropriate sensing and/or delivery of therapies. A medical magnet was also available on site. Emergency medical services and physician supervision were available at all times, and patients were contacted the following day to ensure their well-being. No device interactions were identified at both the nominal and highest sensitivity settings of each ICD during exposure to vehicle charging using a Tesla 220-V wall charger and a 480-V Supercharger at any of the five positions in and around each vehicle. Interaction was defined as oversensing, undersensing, mode switch, or upper rate tracking behavior. There was also no damage to any ICD, and no inappropriate shocks were administered to any patient. In conclusion, transvenous ICD function is not interrupted by EMI transmitted while charging Tesla vehicles using either the 220-V wall charger or the 480-V Supercharger. |
format | Online Article Text |
id | pubmed-10621619 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MediaSphere Medical |
record_format | MEDLINE/PubMed |
spelling | pubmed-106216192023-11-03 The Impact of Electromagnetic Interference from Charging All-electric Vehicles on Implantable Cardioverter-defibrillator Performance Wase, Abdul Hussain, Umbreen Azmat Ratajczak, Theresa Aung, Thein Tun Ali, Omair Markert, Ronald J. J Innov Card Rhythm Manag Original Research Electric vehicles (EVs) are growing in popularity and in general use. The effect of electromagnetic interference (EMI) caused by supercharging all-electric vehicles on implantable cardioverter-defibrillator (ICD) function has not been studied. The objective of this study was to determine the extent of the effect of EMI from charging Tesla all-electric vehicles (Tesla, Inc., Austin, TX, USA) on cardiac implantable electronic device function. A proof-of-concept study was performed to explore the potential effect of EMI from Tesla vehicles while charging the battery using a 220-V wall charger and a 480-V Supercharger. Tesla Model S and Model X vehicles were used for this study. We enrolled 34 patients with stable ICD function for the initial phase using the standard wall charger, followed by an additional 35 patients for the second phase using the Supercharger. Tracings were obtained at nominal and highest sensitivity settings while patients sat in the driver’s seat, passenger seat, back seats, and facing the charging port. In each position, the device and the patient were monitored in real time by a certified technician for any inappropriate sensing and/or delivery of therapies. A medical magnet was also available on site. Emergency medical services and physician supervision were available at all times, and patients were contacted the following day to ensure their well-being. No device interactions were identified at both the nominal and highest sensitivity settings of each ICD during exposure to vehicle charging using a Tesla 220-V wall charger and a 480-V Supercharger at any of the five positions in and around each vehicle. Interaction was defined as oversensing, undersensing, mode switch, or upper rate tracking behavior. There was also no damage to any ICD, and no inappropriate shocks were administered to any patient. In conclusion, transvenous ICD function is not interrupted by EMI transmitted while charging Tesla vehicles using either the 220-V wall charger or the 480-V Supercharger. MediaSphere Medical 2023-10-15 /pmc/articles/PMC10621619/ /pubmed/37927392 http://dx.doi.org/10.19102/icrm.2023.14102 Text en Copyright: © 2023 Innovations in Cardiac Rhythm Management https://creativecommons.org/licenses/by/4.0/This article is available under a Creative Commons License (Attribution 4.0 International, as described at https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Original Research Wase, Abdul Hussain, Umbreen Azmat Ratajczak, Theresa Aung, Thein Tun Ali, Omair Markert, Ronald J. The Impact of Electromagnetic Interference from Charging All-electric Vehicles on Implantable Cardioverter-defibrillator Performance |
title | The Impact of Electromagnetic Interference from Charging All-electric Vehicles on Implantable Cardioverter-defibrillator Performance |
title_full | The Impact of Electromagnetic Interference from Charging All-electric Vehicles on Implantable Cardioverter-defibrillator Performance |
title_fullStr | The Impact of Electromagnetic Interference from Charging All-electric Vehicles on Implantable Cardioverter-defibrillator Performance |
title_full_unstemmed | The Impact of Electromagnetic Interference from Charging All-electric Vehicles on Implantable Cardioverter-defibrillator Performance |
title_short | The Impact of Electromagnetic Interference from Charging All-electric Vehicles on Implantable Cardioverter-defibrillator Performance |
title_sort | impact of electromagnetic interference from charging all-electric vehicles on implantable cardioverter-defibrillator performance |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10621619/ https://www.ncbi.nlm.nih.gov/pubmed/37927392 http://dx.doi.org/10.19102/icrm.2023.14102 |
work_keys_str_mv | AT waseabdul theimpactofelectromagneticinterferencefromchargingallelectricvehiclesonimplantablecardioverterdefibrillatorperformance AT hussainumbreenazmat theimpactofelectromagneticinterferencefromchargingallelectricvehiclesonimplantablecardioverterdefibrillatorperformance AT ratajczaktheresa theimpactofelectromagneticinterferencefromchargingallelectricvehiclesonimplantablecardioverterdefibrillatorperformance AT aungtheintun theimpactofelectromagneticinterferencefromchargingallelectricvehiclesonimplantablecardioverterdefibrillatorperformance AT aliomair theimpactofelectromagneticinterferencefromchargingallelectricvehiclesonimplantablecardioverterdefibrillatorperformance AT markertronaldj theimpactofelectromagneticinterferencefromchargingallelectricvehiclesonimplantablecardioverterdefibrillatorperformance AT waseabdul impactofelectromagneticinterferencefromchargingallelectricvehiclesonimplantablecardioverterdefibrillatorperformance AT hussainumbreenazmat impactofelectromagneticinterferencefromchargingallelectricvehiclesonimplantablecardioverterdefibrillatorperformance AT ratajczaktheresa impactofelectromagneticinterferencefromchargingallelectricvehiclesonimplantablecardioverterdefibrillatorperformance AT aungtheintun impactofelectromagneticinterferencefromchargingallelectricvehiclesonimplantablecardioverterdefibrillatorperformance AT aliomair impactofelectromagneticinterferencefromchargingallelectricvehiclesonimplantablecardioverterdefibrillatorperformance AT markertronaldj impactofelectromagneticinterferencefromchargingallelectricvehiclesonimplantablecardioverterdefibrillatorperformance |