Cargando…
A novel artificial vertebral implant with Gyroid porous structures for reducing the subsidence and mechanical failure rate after vertebral body replacement
BACKGROUND: Prosthesis subsidence and mechanical failure were considered significant threats after vertebral body replacement during the long-term follow-up. Therefore, improving and optimizing the structure of vertebral substitutes for exceptional performance has become a pivotal challenge in spina...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10623881/ https://www.ncbi.nlm.nih.gov/pubmed/37924130 http://dx.doi.org/10.1186/s13018-023-04310-6 |
_version_ | 1785130832272293888 |
---|---|
author | Shang, Peng Ma, Benyuan Hou, Guanghui Zhang, Yihai Cui, Lunxu Song, Wanzhen Liu, Yancheng |
author_facet | Shang, Peng Ma, Benyuan Hou, Guanghui Zhang, Yihai Cui, Lunxu Song, Wanzhen Liu, Yancheng |
author_sort | Shang, Peng |
collection | PubMed |
description | BACKGROUND: Prosthesis subsidence and mechanical failure were considered significant threats after vertebral body replacement during the long-term follow-up. Therefore, improving and optimizing the structure of vertebral substitutes for exceptional performance has become a pivotal challenge in spinal reconstruction. METHODS: The study aimed to develop a novel artificial vertebral implant (AVI) with triply periodic minimal surface Gyroid porous structures to enhance the safety and stability of prostheses. The biomechanical performance of AVIs under different loading conditions was analyzed using the finite element method. These implants were fabricated using selective laser melting technology and evaluated through static compression and subsidence experiments. RESULTS: The results demonstrated that the peak stress in the Gyroid porous AVI was consistently lower than that in the traditional porous AVI under all loading conditions, with a maximum reduction of 73.4%. Additionally, it effectively reduced peak stress at the bone-implant interface of the vertebrae. Static compression experiments demonstrated that the Gyroid porous AVI was about 1.63 times to traditional porous AVI in terms of the maximum compression load, indicating that Gyroid porous AVI could meet the safety requirement. Furthermore, static subsidence experiments revealed that the subsidence tendency of Gyroid porous AVI in polyurethane foam (simulated cancellous bone) was approximately 15.7% lower than that of traditional porous AVI. CONCLUSIONS: The Gyroid porous AVI exhibited higher compressive strength and lower subsidence tendency than the strut-based traditional porous AVI, indicating it may be a promising substitute for spinal reconstruction. |
format | Online Article Text |
id | pubmed-10623881 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-106238812023-11-04 A novel artificial vertebral implant with Gyroid porous structures for reducing the subsidence and mechanical failure rate after vertebral body replacement Shang, Peng Ma, Benyuan Hou, Guanghui Zhang, Yihai Cui, Lunxu Song, Wanzhen Liu, Yancheng J Orthop Surg Res Research Article BACKGROUND: Prosthesis subsidence and mechanical failure were considered significant threats after vertebral body replacement during the long-term follow-up. Therefore, improving and optimizing the structure of vertebral substitutes for exceptional performance has become a pivotal challenge in spinal reconstruction. METHODS: The study aimed to develop a novel artificial vertebral implant (AVI) with triply periodic minimal surface Gyroid porous structures to enhance the safety and stability of prostheses. The biomechanical performance of AVIs under different loading conditions was analyzed using the finite element method. These implants were fabricated using selective laser melting technology and evaluated through static compression and subsidence experiments. RESULTS: The results demonstrated that the peak stress in the Gyroid porous AVI was consistently lower than that in the traditional porous AVI under all loading conditions, with a maximum reduction of 73.4%. Additionally, it effectively reduced peak stress at the bone-implant interface of the vertebrae. Static compression experiments demonstrated that the Gyroid porous AVI was about 1.63 times to traditional porous AVI in terms of the maximum compression load, indicating that Gyroid porous AVI could meet the safety requirement. Furthermore, static subsidence experiments revealed that the subsidence tendency of Gyroid porous AVI in polyurethane foam (simulated cancellous bone) was approximately 15.7% lower than that of traditional porous AVI. CONCLUSIONS: The Gyroid porous AVI exhibited higher compressive strength and lower subsidence tendency than the strut-based traditional porous AVI, indicating it may be a promising substitute for spinal reconstruction. BioMed Central 2023-11-03 /pmc/articles/PMC10623881/ /pubmed/37924130 http://dx.doi.org/10.1186/s13018-023-04310-6 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Shang, Peng Ma, Benyuan Hou, Guanghui Zhang, Yihai Cui, Lunxu Song, Wanzhen Liu, Yancheng A novel artificial vertebral implant with Gyroid porous structures for reducing the subsidence and mechanical failure rate after vertebral body replacement |
title | A novel artificial vertebral implant with Gyroid porous structures for reducing the subsidence and mechanical failure rate after vertebral body replacement |
title_full | A novel artificial vertebral implant with Gyroid porous structures for reducing the subsidence and mechanical failure rate after vertebral body replacement |
title_fullStr | A novel artificial vertebral implant with Gyroid porous structures for reducing the subsidence and mechanical failure rate after vertebral body replacement |
title_full_unstemmed | A novel artificial vertebral implant with Gyroid porous structures for reducing the subsidence and mechanical failure rate after vertebral body replacement |
title_short | A novel artificial vertebral implant with Gyroid porous structures for reducing the subsidence and mechanical failure rate after vertebral body replacement |
title_sort | novel artificial vertebral implant with gyroid porous structures for reducing the subsidence and mechanical failure rate after vertebral body replacement |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10623881/ https://www.ncbi.nlm.nih.gov/pubmed/37924130 http://dx.doi.org/10.1186/s13018-023-04310-6 |
work_keys_str_mv | AT shangpeng anovelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement AT mabenyuan anovelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement AT houguanghui anovelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement AT zhangyihai anovelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement AT cuilunxu anovelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement AT songwanzhen anovelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement AT liuyancheng anovelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement AT shangpeng novelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement AT mabenyuan novelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement AT houguanghui novelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement AT zhangyihai novelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement AT cuilunxu novelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement AT songwanzhen novelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement AT liuyancheng novelartificialvertebralimplantwithgyroidporousstructuresforreducingthesubsidenceandmechanicalfailurerateaftervertebralbodyreplacement |