Cargando…
Nasolacrimal Duct Coronary Stent Recanalization (NCR): First Cadaver Experience and Its Potential as an Alternative to DCR
PURPOSE: To investigate the feasibility of implanting a drug-eluting cobalt-chromium alloy coronary stent in the nasolacrimal ducts (NLDs) of human cadavers. METHODS: The pilot study was carried out in 5 NLDs of 4 adult human cadavers. Sirolimus-eluting coronary stents of 2 mm in width and lengths o...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10624404/ https://www.ncbi.nlm.nih.gov/pubmed/36877544 http://dx.doi.org/10.1097/IOP.0000000000002381 |
_version_ | 1785130917054906368 |
---|---|
author | Ali, Mohammad Javed |
author_facet | Ali, Mohammad Javed |
author_sort | Ali, Mohammad Javed |
collection | PubMed |
description | PURPOSE: To investigate the feasibility of implanting a drug-eluting cobalt-chromium alloy coronary stent in the nasolacrimal ducts (NLDs) of human cadavers. METHODS: The pilot study was carried out in 5 NLDs of 4 adult human cadavers. Sirolimus-eluting coronary stents of 2 mm in width and lengths of 8 and 12 mm, which were mounted on balloon catheters, were used. Following dilatation of the NLDs, the balloon catheters were introduced into the NLDs under direct endoscopy guidance. The stents were delivered following dilatation of the balloon to 12 ATMs and secured in a locked (spring out) position. The balloon is then deflated and securely extubated. The dacryoendoscopy confirmed the stent position. The lacrimal system was then dissected to assess several key parameters like the uniformity of the NLD expansion, anatomical interactions of the NLD mucosa with the stent rings and struts, integrity of the soft and bony NLD, stent movement on mechanical push and pull, and ease of manual removal. RESULTS: The cobalt-chromium alloy coronary stents could be delivered with ease and secured in the cadaveric NLDs. Its position was confirmed by a dacryoendoscopy and later by the direct NLD dissection. The NLD was uniformly dilated 360° with a wide and uniform lumen. NLD mucosa was noted to be uniformly distributed in spaces between the stent rings without influencing the expanded lumen. Following the lacrimal sac’s dissection, the NLD stent showed significant resistance to downward movement but could be easily retrieved with forceps. The 12-mm stents could reach the near total length of the NLD with good luminal expansion. The integrity of the bony and soft-tissue NLD was maintained. The learning curve is shallow if the surgeon is adept with the techniques of balloon dacryoplasty. CONCLUSION: Drug-eluting cobalt-chromium alloy coronary stents can be precisely deployed and secured within the human NLDs. The study is the first of its kind to demonstrate the technique of NLD coronary stent recanalization in human cadavers. It is a step forward in the journey to evaluate their use in patients with primary acquired NLD obstructions and other NLD disorders. |
format | Online Article Text |
id | pubmed-10624404 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-106244042023-11-04 Nasolacrimal Duct Coronary Stent Recanalization (NCR): First Cadaver Experience and Its Potential as an Alternative to DCR Ali, Mohammad Javed Ophthalmic Plast Reconstr Surg Original Investigations PURPOSE: To investigate the feasibility of implanting a drug-eluting cobalt-chromium alloy coronary stent in the nasolacrimal ducts (NLDs) of human cadavers. METHODS: The pilot study was carried out in 5 NLDs of 4 adult human cadavers. Sirolimus-eluting coronary stents of 2 mm in width and lengths of 8 and 12 mm, which were mounted on balloon catheters, were used. Following dilatation of the NLDs, the balloon catheters were introduced into the NLDs under direct endoscopy guidance. The stents were delivered following dilatation of the balloon to 12 ATMs and secured in a locked (spring out) position. The balloon is then deflated and securely extubated. The dacryoendoscopy confirmed the stent position. The lacrimal system was then dissected to assess several key parameters like the uniformity of the NLD expansion, anatomical interactions of the NLD mucosa with the stent rings and struts, integrity of the soft and bony NLD, stent movement on mechanical push and pull, and ease of manual removal. RESULTS: The cobalt-chromium alloy coronary stents could be delivered with ease and secured in the cadaveric NLDs. Its position was confirmed by a dacryoendoscopy and later by the direct NLD dissection. The NLD was uniformly dilated 360° with a wide and uniform lumen. NLD mucosa was noted to be uniformly distributed in spaces between the stent rings without influencing the expanded lumen. Following the lacrimal sac’s dissection, the NLD stent showed significant resistance to downward movement but could be easily retrieved with forceps. The 12-mm stents could reach the near total length of the NLD with good luminal expansion. The integrity of the bony and soft-tissue NLD was maintained. The learning curve is shallow if the surgeon is adept with the techniques of balloon dacryoplasty. CONCLUSION: Drug-eluting cobalt-chromium alloy coronary stents can be precisely deployed and secured within the human NLDs. The study is the first of its kind to demonstrate the technique of NLD coronary stent recanalization in human cadavers. It is a step forward in the journey to evaluate their use in patients with primary acquired NLD obstructions and other NLD disorders. Lippincott Williams & Wilkins 2023-03-03 2023 /pmc/articles/PMC10624404/ /pubmed/36877544 http://dx.doi.org/10.1097/IOP.0000000000002381 Text en Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Society of Ophthalmic Plastic and Reconstructive Surgery, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Original Investigations Ali, Mohammad Javed Nasolacrimal Duct Coronary Stent Recanalization (NCR): First Cadaver Experience and Its Potential as an Alternative to DCR |
title | Nasolacrimal Duct Coronary Stent Recanalization (NCR): First Cadaver Experience and Its Potential as an Alternative to DCR |
title_full | Nasolacrimal Duct Coronary Stent Recanalization (NCR): First Cadaver Experience and Its Potential as an Alternative to DCR |
title_fullStr | Nasolacrimal Duct Coronary Stent Recanalization (NCR): First Cadaver Experience and Its Potential as an Alternative to DCR |
title_full_unstemmed | Nasolacrimal Duct Coronary Stent Recanalization (NCR): First Cadaver Experience and Its Potential as an Alternative to DCR |
title_short | Nasolacrimal Duct Coronary Stent Recanalization (NCR): First Cadaver Experience and Its Potential as an Alternative to DCR |
title_sort | nasolacrimal duct coronary stent recanalization (ncr): first cadaver experience and its potential as an alternative to dcr |
topic | Original Investigations |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10624404/ https://www.ncbi.nlm.nih.gov/pubmed/36877544 http://dx.doi.org/10.1097/IOP.0000000000002381 |
work_keys_str_mv | AT alimohammadjaved nasolacrimalductcoronarystentrecanalizationncrfirstcadaverexperienceanditspotentialasanalternativetodcr |