Cargando…
Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments
OBJECTIVE: The aim of the study was to determine the intra- and inter-rater reliability of palpation technique, digital calipers, and diastometer, as well as their concurrent validity against ultrasound imaging. METHODS: Ninety consenting parous women (20–45 years), recruited from a postnatal clinic...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Qassim Uninversity
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10624799/ https://www.ncbi.nlm.nih.gov/pubmed/37929234 |
_version_ | 1785130987936546816 |
---|---|
author | Petronilla, Ojukwu Chidiebele Uruchi, Ezeigwe Anne Francis, Ezeigwe Chukwudi Linda, Ugwuonye Chioma |
author_facet | Petronilla, Ojukwu Chidiebele Uruchi, Ezeigwe Anne Francis, Ezeigwe Chukwudi Linda, Ugwuonye Chioma |
author_sort | Petronilla, Ojukwu Chidiebele |
collection | PubMed |
description | OBJECTIVE: The aim of the study was to determine the intra- and inter-rater reliability of palpation technique, digital calipers, and diastometer, as well as their concurrent validity against ultrasound imaging. METHODS: Ninety consenting parous women (20–45 years), recruited from a postnatal clinic in Enugu, Nigeria, participated in this observational study. Two physiotherapists and a sonographer measured their inter rectus distance at the level of the umbilicus, 4.5 cm above and below it, respectively, using each of the four modalities. The intra-rater measurements were taken at a week’s interval. Data were analyzed with descriptive and inferential statistics of intraclass correlation coefficient and paired samples T-test, at an alpha level set at P < 0.05. RESULTS: It showed the palpation technique (r = 0.749–0.967 and 0.658–0.917), digital calipers (r=0.750–0.955 and 0.685–0.904), and diastometer (r=0.762–0.958 and 0.471–0.902) demonstrated good inter- and intra-rater reliability. The concurrent validity of the palpation technique, digital calipers, and diastometer against the USI was poor at all three reference points. CONCLUSION: Palpation technique, digital calipers, and diastometer are reliable tools but not valid substitutes to ultrasound imaging for the clinical measurement of diastasis rectus abdominis. |
format | Online Article Text |
id | pubmed-10624799 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Qassim Uninversity |
record_format | MEDLINE/PubMed |
spelling | pubmed-106247992023-11-05 Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments Petronilla, Ojukwu Chidiebele Uruchi, Ezeigwe Anne Francis, Ezeigwe Chukwudi Linda, Ugwuonye Chioma Int J Health Sci (Qassim) Original Article OBJECTIVE: The aim of the study was to determine the intra- and inter-rater reliability of palpation technique, digital calipers, and diastometer, as well as their concurrent validity against ultrasound imaging. METHODS: Ninety consenting parous women (20–45 years), recruited from a postnatal clinic in Enugu, Nigeria, participated in this observational study. Two physiotherapists and a sonographer measured their inter rectus distance at the level of the umbilicus, 4.5 cm above and below it, respectively, using each of the four modalities. The intra-rater measurements were taken at a week’s interval. Data were analyzed with descriptive and inferential statistics of intraclass correlation coefficient and paired samples T-test, at an alpha level set at P < 0.05. RESULTS: It showed the palpation technique (r = 0.749–0.967 and 0.658–0.917), digital calipers (r=0.750–0.955 and 0.685–0.904), and diastometer (r=0.762–0.958 and 0.471–0.902) demonstrated good inter- and intra-rater reliability. The concurrent validity of the palpation technique, digital calipers, and diastometer against the USI was poor at all three reference points. CONCLUSION: Palpation technique, digital calipers, and diastometer are reliable tools but not valid substitutes to ultrasound imaging for the clinical measurement of diastasis rectus abdominis. Qassim Uninversity 2023 /pmc/articles/PMC10624799/ /pubmed/37929234 Text en Copyright: © International Journal of Health Sciences https://creativecommons.org/licenses/by-nc-sa/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Petronilla, Ojukwu Chidiebele Uruchi, Ezeigwe Anne Francis, Ezeigwe Chukwudi Linda, Ugwuonye Chioma Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments |
title | Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments |
title_full | Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments |
title_fullStr | Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments |
title_full_unstemmed | Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments |
title_short | Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments |
title_sort | assessment of diastasis recti abdominis: clinimetric properties of four measuring instruments |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10624799/ https://www.ncbi.nlm.nih.gov/pubmed/37929234 |
work_keys_str_mv | AT petronillaojukwuchidiebele assessmentofdiastasisrectiabdominisclinimetricpropertiesoffourmeasuringinstruments AT uruchiezeigweanne assessmentofdiastasisrectiabdominisclinimetricpropertiesoffourmeasuringinstruments AT francisezeigwechukwudi assessmentofdiastasisrectiabdominisclinimetricpropertiesoffourmeasuringinstruments AT lindaugwuonyechioma assessmentofdiastasisrectiabdominisclinimetricpropertiesoffourmeasuringinstruments |