Cargando…

Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments

OBJECTIVE: The aim of the study was to determine the intra- and inter-rater reliability of palpation technique, digital calipers, and diastometer, as well as their concurrent validity against ultrasound imaging. METHODS: Ninety consenting parous women (20–45 years), recruited from a postnatal clinic...

Descripción completa

Detalles Bibliográficos
Autores principales: Petronilla, Ojukwu Chidiebele, Uruchi, Ezeigwe Anne, Francis, Ezeigwe Chukwudi, Linda, Ugwuonye Chioma
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Qassim Uninversity 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10624799/
https://www.ncbi.nlm.nih.gov/pubmed/37929234
_version_ 1785130987936546816
author Petronilla, Ojukwu Chidiebele
Uruchi, Ezeigwe Anne
Francis, Ezeigwe Chukwudi
Linda, Ugwuonye Chioma
author_facet Petronilla, Ojukwu Chidiebele
Uruchi, Ezeigwe Anne
Francis, Ezeigwe Chukwudi
Linda, Ugwuonye Chioma
author_sort Petronilla, Ojukwu Chidiebele
collection PubMed
description OBJECTIVE: The aim of the study was to determine the intra- and inter-rater reliability of palpation technique, digital calipers, and diastometer, as well as their concurrent validity against ultrasound imaging. METHODS: Ninety consenting parous women (20–45 years), recruited from a postnatal clinic in Enugu, Nigeria, participated in this observational study. Two physiotherapists and a sonographer measured their inter rectus distance at the level of the umbilicus, 4.5 cm above and below it, respectively, using each of the four modalities. The intra-rater measurements were taken at a week’s interval. Data were analyzed with descriptive and inferential statistics of intraclass correlation coefficient and paired samples T-test, at an alpha level set at P < 0.05. RESULTS: It showed the palpation technique (r = 0.749–0.967 and 0.658–0.917), digital calipers (r=0.750–0.955 and 0.685–0.904), and diastometer (r=0.762–0.958 and 0.471–0.902) demonstrated good inter- and intra-rater reliability. The concurrent validity of the palpation technique, digital calipers, and diastometer against the USI was poor at all three reference points. CONCLUSION: Palpation technique, digital calipers, and diastometer are reliable tools but not valid substitutes to ultrasound imaging for the clinical measurement of diastasis rectus abdominis.
format Online
Article
Text
id pubmed-10624799
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Qassim Uninversity
record_format MEDLINE/PubMed
spelling pubmed-106247992023-11-05 Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments Petronilla, Ojukwu Chidiebele Uruchi, Ezeigwe Anne Francis, Ezeigwe Chukwudi Linda, Ugwuonye Chioma Int J Health Sci (Qassim) Original Article OBJECTIVE: The aim of the study was to determine the intra- and inter-rater reliability of palpation technique, digital calipers, and diastometer, as well as their concurrent validity against ultrasound imaging. METHODS: Ninety consenting parous women (20–45 years), recruited from a postnatal clinic in Enugu, Nigeria, participated in this observational study. Two physiotherapists and a sonographer measured their inter rectus distance at the level of the umbilicus, 4.5 cm above and below it, respectively, using each of the four modalities. The intra-rater measurements were taken at a week’s interval. Data were analyzed with descriptive and inferential statistics of intraclass correlation coefficient and paired samples T-test, at an alpha level set at P < 0.05. RESULTS: It showed the palpation technique (r = 0.749–0.967 and 0.658–0.917), digital calipers (r=0.750–0.955 and 0.685–0.904), and diastometer (r=0.762–0.958 and 0.471–0.902) demonstrated good inter- and intra-rater reliability. The concurrent validity of the palpation technique, digital calipers, and diastometer against the USI was poor at all three reference points. CONCLUSION: Palpation technique, digital calipers, and diastometer are reliable tools but not valid substitutes to ultrasound imaging for the clinical measurement of diastasis rectus abdominis. Qassim Uninversity 2023 /pmc/articles/PMC10624799/ /pubmed/37929234 Text en Copyright: © International Journal of Health Sciences https://creativecommons.org/licenses/by-nc-sa/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Petronilla, Ojukwu Chidiebele
Uruchi, Ezeigwe Anne
Francis, Ezeigwe Chukwudi
Linda, Ugwuonye Chioma
Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments
title Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments
title_full Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments
title_fullStr Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments
title_full_unstemmed Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments
title_short Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments
title_sort assessment of diastasis recti abdominis: clinimetric properties of four measuring instruments
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10624799/
https://www.ncbi.nlm.nih.gov/pubmed/37929234
work_keys_str_mv AT petronillaojukwuchidiebele assessmentofdiastasisrectiabdominisclinimetricpropertiesoffourmeasuringinstruments
AT uruchiezeigweanne assessmentofdiastasisrectiabdominisclinimetricpropertiesoffourmeasuringinstruments
AT francisezeigwechukwudi assessmentofdiastasisrectiabdominisclinimetricpropertiesoffourmeasuringinstruments
AT lindaugwuonyechioma assessmentofdiastasisrectiabdominisclinimetricpropertiesoffourmeasuringinstruments