Cargando…

Comparison of invasive and non-invasive measurements of cardiac index and systemic vascular resistance in living-donor liver transplantation: a prospective, observational study

BACKGROUND: Based on the controversy surrounding pulmonary artery catheterization (PAC) in surgical patients, we investigated the interchangeability of cardiac index (CI) and systemic vascular resistance (SVR) measurements between ClearSight™ and PAC during living-donor liver transplantation (LDLT)....

Descripción completa

Detalles Bibliográficos
Autores principales: Cho, Hye-Yeon, Lee, Ho-Jin, Hwang, In Eob, Lee, Hyung-Chul, Kim, Won Ho, Yang, Seong-Mi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625262/
https://www.ncbi.nlm.nih.gov/pubmed/37924013
http://dx.doi.org/10.1186/s12871-023-02302-x
_version_ 1785131094731915264
author Cho, Hye-Yeon
Lee, Ho-Jin
Hwang, In Eob
Lee, Hyung-Chul
Kim, Won Ho
Yang, Seong-Mi
author_facet Cho, Hye-Yeon
Lee, Ho-Jin
Hwang, In Eob
Lee, Hyung-Chul
Kim, Won Ho
Yang, Seong-Mi
author_sort Cho, Hye-Yeon
collection PubMed
description BACKGROUND: Based on the controversy surrounding pulmonary artery catheterization (PAC) in surgical patients, we investigated the interchangeability of cardiac index (CI) and systemic vascular resistance (SVR) measurements between ClearSight™ and PAC during living-donor liver transplantation (LDLT). METHODS: This prospective study included consecutively selected LDLT patients. ClearSight™-based CI and SVR measurements were compared with those from PAC at seven LDLT-stage time points. ClearSight™-based systolic (SAP), mean (MAP), and diastolic (DAP) arterial pressures were also compared with those from femoral arterial catheterization (FAC). For the comparison and analysis of ClearSight™ and the reference method, Bland-Altman analysis was used to analyze accuracy while polar and four-quadrant plots were used to analyze the trending ability. RESULTS: From 27 patients, 189 pairs of ClearSight™ and reference values were analyzed. The CI and SVR performance errors (PEs) exhibited poor accuracy between the two methods (51.52 and 51.73%, respectively) in the Bland-Altman analysis. CI and SVR also exhibited unacceptable trending abilities in both the polar and four-quadrant plot analyses. SAP, MAP, and DAP PEs between the two methods displayed favorable accuracy (24.28, 21.18, and 26.26%, respectively). SAP and MAP exhibited acceptable trending ability in the four-quadrant plot between the two methods, but not in the polar plot analyses. CONCLUSIONS: During LDLT, CI and SVR demonstrated poor interchangeability, while SAP and MAP exhibited acceptable interchangeability between ClearSight™ and FAC.
format Online
Article
Text
id pubmed-10625262
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-106252622023-11-05 Comparison of invasive and non-invasive measurements of cardiac index and systemic vascular resistance in living-donor liver transplantation: a prospective, observational study Cho, Hye-Yeon Lee, Ho-Jin Hwang, In Eob Lee, Hyung-Chul Kim, Won Ho Yang, Seong-Mi BMC Anesthesiol Research BACKGROUND: Based on the controversy surrounding pulmonary artery catheterization (PAC) in surgical patients, we investigated the interchangeability of cardiac index (CI) and systemic vascular resistance (SVR) measurements between ClearSight™ and PAC during living-donor liver transplantation (LDLT). METHODS: This prospective study included consecutively selected LDLT patients. ClearSight™-based CI and SVR measurements were compared with those from PAC at seven LDLT-stage time points. ClearSight™-based systolic (SAP), mean (MAP), and diastolic (DAP) arterial pressures were also compared with those from femoral arterial catheterization (FAC). For the comparison and analysis of ClearSight™ and the reference method, Bland-Altman analysis was used to analyze accuracy while polar and four-quadrant plots were used to analyze the trending ability. RESULTS: From 27 patients, 189 pairs of ClearSight™ and reference values were analyzed. The CI and SVR performance errors (PEs) exhibited poor accuracy between the two methods (51.52 and 51.73%, respectively) in the Bland-Altman analysis. CI and SVR also exhibited unacceptable trending abilities in both the polar and four-quadrant plot analyses. SAP, MAP, and DAP PEs between the two methods displayed favorable accuracy (24.28, 21.18, and 26.26%, respectively). SAP and MAP exhibited acceptable trending ability in the four-quadrant plot between the two methods, but not in the polar plot analyses. CONCLUSIONS: During LDLT, CI and SVR demonstrated poor interchangeability, while SAP and MAP exhibited acceptable interchangeability between ClearSight™ and FAC. BioMed Central 2023-11-04 /pmc/articles/PMC10625262/ /pubmed/37924013 http://dx.doi.org/10.1186/s12871-023-02302-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Cho, Hye-Yeon
Lee, Ho-Jin
Hwang, In Eob
Lee, Hyung-Chul
Kim, Won Ho
Yang, Seong-Mi
Comparison of invasive and non-invasive measurements of cardiac index and systemic vascular resistance in living-donor liver transplantation: a prospective, observational study
title Comparison of invasive and non-invasive measurements of cardiac index and systemic vascular resistance in living-donor liver transplantation: a prospective, observational study
title_full Comparison of invasive and non-invasive measurements of cardiac index and systemic vascular resistance in living-donor liver transplantation: a prospective, observational study
title_fullStr Comparison of invasive and non-invasive measurements of cardiac index and systemic vascular resistance in living-donor liver transplantation: a prospective, observational study
title_full_unstemmed Comparison of invasive and non-invasive measurements of cardiac index and systemic vascular resistance in living-donor liver transplantation: a prospective, observational study
title_short Comparison of invasive and non-invasive measurements of cardiac index and systemic vascular resistance in living-donor liver transplantation: a prospective, observational study
title_sort comparison of invasive and non-invasive measurements of cardiac index and systemic vascular resistance in living-donor liver transplantation: a prospective, observational study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625262/
https://www.ncbi.nlm.nih.gov/pubmed/37924013
http://dx.doi.org/10.1186/s12871-023-02302-x
work_keys_str_mv AT chohyeyeon comparisonofinvasiveandnoninvasivemeasurementsofcardiacindexandsystemicvascularresistanceinlivingdonorlivertransplantationaprospectiveobservationalstudy
AT leehojin comparisonofinvasiveandnoninvasivemeasurementsofcardiacindexandsystemicvascularresistanceinlivingdonorlivertransplantationaprospectiveobservationalstudy
AT hwangineob comparisonofinvasiveandnoninvasivemeasurementsofcardiacindexandsystemicvascularresistanceinlivingdonorlivertransplantationaprospectiveobservationalstudy
AT leehyungchul comparisonofinvasiveandnoninvasivemeasurementsofcardiacindexandsystemicvascularresistanceinlivingdonorlivertransplantationaprospectiveobservationalstudy
AT kimwonho comparisonofinvasiveandnoninvasivemeasurementsofcardiacindexandsystemicvascularresistanceinlivingdonorlivertransplantationaprospectiveobservationalstudy
AT yangseongmi comparisonofinvasiveandnoninvasivemeasurementsofcardiacindexandsystemicvascularresistanceinlivingdonorlivertransplantationaprospectiveobservationalstudy