Cargando…
Diagnostic Accuracy of Fetal Anterior Abdominal Wall Thickness as an Early Sonographic Sign for Diagnosing Gestational Diabetes
Introduction Traditionally, different fetal variable measurements are used in ultrasound to assess fetal growth. Ultrasound can detect abnormal fetal growth. Gestational diabetes mellitus (GDM) is linked to higher fetal obesity as early as 20 weeks of pregnancy. The amount of fetal adipose tissue m...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625453/ https://www.ncbi.nlm.nih.gov/pubmed/37927742 http://dx.doi.org/10.7759/cureus.46538 |
_version_ | 1785131136387645440 |
---|---|
author | Sabir, Muhammad Sharjeel Hassan, Muhammad Mujeeb Malik, Moeena Saleem, Rabia Tariq, Zartasha Zohaib, Khurram Javaid, Maham Malik, Adnan Younas Saleem, Amna |
author_facet | Sabir, Muhammad Sharjeel Hassan, Muhammad Mujeeb Malik, Moeena Saleem, Rabia Tariq, Zartasha Zohaib, Khurram Javaid, Maham Malik, Adnan Younas Saleem, Amna |
author_sort | Sabir, Muhammad Sharjeel |
collection | PubMed |
description | Introduction Traditionally, different fetal variable measurements are used in ultrasound to assess fetal growth. Ultrasound can detect abnormal fetal growth. Gestational diabetes mellitus (GDM) is linked to higher fetal obesity as early as 20 weeks of pregnancy. The amount of fetal adipose tissue may be measured by measuring the thickness of the anterior abdominal wall. Measuring the thickness of the fetus's anterior abdominal wall (AAWT) is a straightforward procedure that may be performed alongside standard abdominal circumference measurements. Objectives To check the diagnostic accuracy of fetal AAWT as an early sonographic sign for diagnosing GDM, keeping oral glucose tolerance test as the gold standard. Study design This research was conducted using a cross-sectional analysis. Study place and duration The study was conducted in the Radiology Department at Rawalpindi Medical University and Allied Hospitals from July 10, 2019 to January 9, 2020. Materials and methods Women between the ages of 18 and 45 who had a family history of type 2 diabetes and were at risk for developing GDM were recruited. Exclusions were made for diabetic women, those carrying multiples, and those with autoimmune diseases. The AAWT measurement of the fetus, which included the skin and subcutaneous tissue, was acquired using the traditional anterior cranial view, 2-3 cm lateral to cord insertion. Pregnant patients at risk for GDM underwent screening using an oral glucose tolerance test. Those exhibiting any two abnormal values were diagnosed with GDM. Results The overall sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of fetal AAWT as an early sonographic sign for diagnosing GDM, with the oral glucose tolerance test as the gold standard, were 93.14%, 82.65%, 84.82%, 92.05%, and 88.0%, respectively. Conclusion The study concludes that the diagnostic accuracy of fetal AAWT as an early sonographic indicator for identifying gestational diabetes is notably high. |
format | Online Article Text |
id | pubmed-10625453 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-106254532023-11-05 Diagnostic Accuracy of Fetal Anterior Abdominal Wall Thickness as an Early Sonographic Sign for Diagnosing Gestational Diabetes Sabir, Muhammad Sharjeel Hassan, Muhammad Mujeeb Malik, Moeena Saleem, Rabia Tariq, Zartasha Zohaib, Khurram Javaid, Maham Malik, Adnan Younas Saleem, Amna Cureus Endocrinology/Diabetes/Metabolism Introduction Traditionally, different fetal variable measurements are used in ultrasound to assess fetal growth. Ultrasound can detect abnormal fetal growth. Gestational diabetes mellitus (GDM) is linked to higher fetal obesity as early as 20 weeks of pregnancy. The amount of fetal adipose tissue may be measured by measuring the thickness of the anterior abdominal wall. Measuring the thickness of the fetus's anterior abdominal wall (AAWT) is a straightforward procedure that may be performed alongside standard abdominal circumference measurements. Objectives To check the diagnostic accuracy of fetal AAWT as an early sonographic sign for diagnosing GDM, keeping oral glucose tolerance test as the gold standard. Study design This research was conducted using a cross-sectional analysis. Study place and duration The study was conducted in the Radiology Department at Rawalpindi Medical University and Allied Hospitals from July 10, 2019 to January 9, 2020. Materials and methods Women between the ages of 18 and 45 who had a family history of type 2 diabetes and were at risk for developing GDM were recruited. Exclusions were made for diabetic women, those carrying multiples, and those with autoimmune diseases. The AAWT measurement of the fetus, which included the skin and subcutaneous tissue, was acquired using the traditional anterior cranial view, 2-3 cm lateral to cord insertion. Pregnant patients at risk for GDM underwent screening using an oral glucose tolerance test. Those exhibiting any two abnormal values were diagnosed with GDM. Results The overall sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of fetal AAWT as an early sonographic sign for diagnosing GDM, with the oral glucose tolerance test as the gold standard, were 93.14%, 82.65%, 84.82%, 92.05%, and 88.0%, respectively. Conclusion The study concludes that the diagnostic accuracy of fetal AAWT as an early sonographic indicator for identifying gestational diabetes is notably high. Cureus 2023-10-05 /pmc/articles/PMC10625453/ /pubmed/37927742 http://dx.doi.org/10.7759/cureus.46538 Text en Copyright © 2023, Sabir et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Endocrinology/Diabetes/Metabolism Sabir, Muhammad Sharjeel Hassan, Muhammad Mujeeb Malik, Moeena Saleem, Rabia Tariq, Zartasha Zohaib, Khurram Javaid, Maham Malik, Adnan Younas Saleem, Amna Diagnostic Accuracy of Fetal Anterior Abdominal Wall Thickness as an Early Sonographic Sign for Diagnosing Gestational Diabetes |
title | Diagnostic Accuracy of Fetal Anterior Abdominal Wall Thickness as an Early Sonographic Sign for Diagnosing Gestational Diabetes |
title_full | Diagnostic Accuracy of Fetal Anterior Abdominal Wall Thickness as an Early Sonographic Sign for Diagnosing Gestational Diabetes |
title_fullStr | Diagnostic Accuracy of Fetal Anterior Abdominal Wall Thickness as an Early Sonographic Sign for Diagnosing Gestational Diabetes |
title_full_unstemmed | Diagnostic Accuracy of Fetal Anterior Abdominal Wall Thickness as an Early Sonographic Sign for Diagnosing Gestational Diabetes |
title_short | Diagnostic Accuracy of Fetal Anterior Abdominal Wall Thickness as an Early Sonographic Sign for Diagnosing Gestational Diabetes |
title_sort | diagnostic accuracy of fetal anterior abdominal wall thickness as an early sonographic sign for diagnosing gestational diabetes |
topic | Endocrinology/Diabetes/Metabolism |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625453/ https://www.ncbi.nlm.nih.gov/pubmed/37927742 http://dx.doi.org/10.7759/cureus.46538 |
work_keys_str_mv | AT sabirmuhammadsharjeel diagnosticaccuracyoffetalanteriorabdominalwallthicknessasanearlysonographicsignfordiagnosinggestationaldiabetes AT hassanmuhammadmujeeb diagnosticaccuracyoffetalanteriorabdominalwallthicknessasanearlysonographicsignfordiagnosinggestationaldiabetes AT malikmoeena diagnosticaccuracyoffetalanteriorabdominalwallthicknessasanearlysonographicsignfordiagnosinggestationaldiabetes AT saleemrabia diagnosticaccuracyoffetalanteriorabdominalwallthicknessasanearlysonographicsignfordiagnosinggestationaldiabetes AT tariqzartasha diagnosticaccuracyoffetalanteriorabdominalwallthicknessasanearlysonographicsignfordiagnosinggestationaldiabetes AT zohaibkhurram diagnosticaccuracyoffetalanteriorabdominalwallthicknessasanearlysonographicsignfordiagnosinggestationaldiabetes AT javaidmaham diagnosticaccuracyoffetalanteriorabdominalwallthicknessasanearlysonographicsignfordiagnosinggestationaldiabetes AT malikadnanyounas diagnosticaccuracyoffetalanteriorabdominalwallthicknessasanearlysonographicsignfordiagnosinggestationaldiabetes AT saleemamna diagnosticaccuracyoffetalanteriorabdominalwallthicknessasanearlysonographicsignfordiagnosinggestationaldiabetes |