Cargando…

Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study

PURPOSE: This study evaluated the reliability of the chair-side CAD-CAM surgical guide (CSG) in the anterior maxilla by comparing its accuracy with the laboratory 3D-printed surgical guide (3DSG) and manual surgical guide (MSG) concerning different levels of dentists' surgical experience. MATER...

Descripción completa

Detalles Bibliográficos
Autores principales: Htay, Phyo Ei Ei, Leesungbok, Richard, Lee, Suk Won, Jee, Yu-Jin, Kang, Kyung Lhi, Hong, Sung Ok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625886/
https://www.ncbi.nlm.nih.gov/pubmed/37936833
http://dx.doi.org/10.4047/jap.2023.15.5.259
_version_ 1785131224771067904
author Htay, Phyo Ei Ei
Leesungbok, Richard
Lee, Suk Won
Jee, Yu-Jin
Kang, Kyung Lhi
Hong, Sung Ok
author_facet Htay, Phyo Ei Ei
Leesungbok, Richard
Lee, Suk Won
Jee, Yu-Jin
Kang, Kyung Lhi
Hong, Sung Ok
author_sort Htay, Phyo Ei Ei
collection PubMed
description PURPOSE: This study evaluated the reliability of the chair-side CAD-CAM surgical guide (CSG) in the anterior maxilla by comparing its accuracy with the laboratory 3D-printed surgical guide (3DSG) and manual surgical guide (MSG) concerning different levels of dentists' surgical experience. MATERIALS AND METHODS: Ten surgical guides of each type (MSG, 3DSG, and CSG) were fabricated on a control study model with missing right and left central incisors. Sixty implants were placed in 30 study models by two dentists (one inexperienced and one experienced) using three different types of surgical guides. Horizontal deviations at shoulder and at apex, vertical, and angular deviations were measured after superimposing the planned and placed implant positions in the software. Kruskal-Wallis and Mann-Whitney U tests were used to compare the accuracy of three types of surgical guides in each dentist group and the accuracy of each surgical guide between two dentists (α = .05). RESULTS: There were no significant differences in any deviations between CSG and 3DSG, apart from angular deviation, for both dentists’ groups. Moreover, both CSG and 3DSG showed no significant differences in accuracy between the two dentists (P > .05). In contrast, MSG demonstrated significant differences from CSG and 3DSG and a significant difference in accuracy between the two dentists (P < .05). CONCLUSION: CSG provides superior accuracy to MSG in implant placement in the maxillary anterior region and is comparable to 3DSG at different levels of surgical experience, while offering the benefits of shorter manufacturing time and reduced patient visits.
format Online
Article
Text
id pubmed-10625886
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-106258862023-11-07 Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study Htay, Phyo Ei Ei Leesungbok, Richard Lee, Suk Won Jee, Yu-Jin Kang, Kyung Lhi Hong, Sung Ok J Adv Prosthodont Original Article PURPOSE: This study evaluated the reliability of the chair-side CAD-CAM surgical guide (CSG) in the anterior maxilla by comparing its accuracy with the laboratory 3D-printed surgical guide (3DSG) and manual surgical guide (MSG) concerning different levels of dentists' surgical experience. MATERIALS AND METHODS: Ten surgical guides of each type (MSG, 3DSG, and CSG) were fabricated on a control study model with missing right and left central incisors. Sixty implants were placed in 30 study models by two dentists (one inexperienced and one experienced) using three different types of surgical guides. Horizontal deviations at shoulder and at apex, vertical, and angular deviations were measured after superimposing the planned and placed implant positions in the software. Kruskal-Wallis and Mann-Whitney U tests were used to compare the accuracy of three types of surgical guides in each dentist group and the accuracy of each surgical guide between two dentists (α = .05). RESULTS: There were no significant differences in any deviations between CSG and 3DSG, apart from angular deviation, for both dentists’ groups. Moreover, both CSG and 3DSG showed no significant differences in accuracy between the two dentists (P > .05). In contrast, MSG demonstrated significant differences from CSG and 3DSG and a significant difference in accuracy between the two dentists (P < .05). CONCLUSION: CSG provides superior accuracy to MSG in implant placement in the maxillary anterior region and is comparable to 3DSG at different levels of surgical experience, while offering the benefits of shorter manufacturing time and reduced patient visits. The Korean Academy of Prosthodontics 2023-10 2023-10-26 /pmc/articles/PMC10625886/ /pubmed/37936833 http://dx.doi.org/10.4047/jap.2023.15.5.259 Text en © 2023 The Korean Academy of Prosthodontics https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Htay, Phyo Ei Ei
Leesungbok, Richard
Lee, Suk Won
Jee, Yu-Jin
Kang, Kyung Lhi
Hong, Sung Ok
Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study
title Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study
title_full Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study
title_fullStr Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study
title_full_unstemmed Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study
title_short Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study
title_sort reliability of a chairside cad-cam surgical guide for dental implant surgery on the anterior maxilla: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625886/
https://www.ncbi.nlm.nih.gov/pubmed/37936833
http://dx.doi.org/10.4047/jap.2023.15.5.259
work_keys_str_mv AT htayphyoeiei reliabilityofachairsidecadcamsurgicalguidefordentalimplantsurgeryontheanteriormaxillaaninvitrostudy
AT leesungbokrichard reliabilityofachairsidecadcamsurgicalguidefordentalimplantsurgeryontheanteriormaxillaaninvitrostudy
AT leesukwon reliabilityofachairsidecadcamsurgicalguidefordentalimplantsurgeryontheanteriormaxillaaninvitrostudy
AT jeeyujin reliabilityofachairsidecadcamsurgicalguidefordentalimplantsurgeryontheanteriormaxillaaninvitrostudy
AT kangkyunglhi reliabilityofachairsidecadcamsurgicalguidefordentalimplantsurgeryontheanteriormaxillaaninvitrostudy
AT hongsungok reliabilityofachairsidecadcamsurgicalguidefordentalimplantsurgeryontheanteriormaxillaaninvitrostudy