Cargando…

In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position

PURPOSE: This in vitro study aimed to compare the accuracy of the conventional facebow system and the newly developed POP (PNUD (Pusan National University Dental School) Occlusal Plane) bow system for occlusal plane transfer in asymmetric ear position. MATERIALS AND METHODS: Two dentists participate...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Dae-Sung, Park, So-Hyung, Ahn, Jong-Ju, Jeong, Chang-Mo, Yun, Mi-Jung, Huh, Jung-Bo, Lee, So-Hyoun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625888/
https://www.ncbi.nlm.nih.gov/pubmed/37936837
http://dx.doi.org/10.4047/jap.2023.15.5.271
Descripción
Sumario:PURPOSE: This in vitro study aimed to compare the accuracy of the conventional facebow system and the newly developed POP (PNUD (Pusan National University Dental School) Occlusal Plane) bow system for occlusal plane transfer in asymmetric ear position. MATERIALS AND METHODS: Two dentists participated in this study, one was categorized as Experimenter 1 and the other as Experimenter 2 based on their clinical experience with the facebow (1F, 2F) and POP bow (1P, 2P) systems. The vertical height difference between the two ears of the phantom model was set to 3 mm. Experimenter 1 and Experimenter 2 performed the facebow and POP bow systems on the phantom model 10 times each, and the transfer accuracy was analyzed. The accuracy was evaluated by measuring the angle between the reference virtual plane (RVP) of the phantom model and the experimental virtual plane (EVP) of the upper mounting plate through digital superimposition. All data were statistically analyzed using a paired t-test (P < .05). RESULTS: Regardless of clinical experience, the POP bow system (0.53° ± 0.30 (1P) and 0.19° ± 0.18 (2P) for Experimenter 1 and 2, respectively) was significantly more accurate than the facebow system (1.88° ± 0.50 (1F) and 1.34° ± 0.25 (2F), respectively) in the frontal view (P < .05). In the sagittal view, no significant differences were found between the POP bow system (0.92° ± 0.50 (1P) and 0.73° ± 0.42 (2P) for Experimenter 1 and 2, respectively) and the facebow system (0.82° ± 0.49 (1F) and 0.60° ± 0.39 (2F), respectively), regardless of clinical experience (P > .05). CONCLUSION: In cases of asymmetric ear position, the POP bow system may transfer occlusal plane information more accurately than the facebow system in the frontal view, regardless of clinical experience.