Cargando…

In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position

PURPOSE: This in vitro study aimed to compare the accuracy of the conventional facebow system and the newly developed POP (PNUD (Pusan National University Dental School) Occlusal Plane) bow system for occlusal plane transfer in asymmetric ear position. MATERIALS AND METHODS: Two dentists participate...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Dae-Sung, Park, So-Hyung, Ahn, Jong-Ju, Jeong, Chang-Mo, Yun, Mi-Jung, Huh, Jung-Bo, Lee, So-Hyoun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625888/
https://www.ncbi.nlm.nih.gov/pubmed/37936837
http://dx.doi.org/10.4047/jap.2023.15.5.271
_version_ 1785131225234538496
author Kim, Dae-Sung
Park, So-Hyung
Ahn, Jong-Ju
Jeong, Chang-Mo
Yun, Mi-Jung
Huh, Jung-Bo
Lee, So-Hyoun
author_facet Kim, Dae-Sung
Park, So-Hyung
Ahn, Jong-Ju
Jeong, Chang-Mo
Yun, Mi-Jung
Huh, Jung-Bo
Lee, So-Hyoun
author_sort Kim, Dae-Sung
collection PubMed
description PURPOSE: This in vitro study aimed to compare the accuracy of the conventional facebow system and the newly developed POP (PNUD (Pusan National University Dental School) Occlusal Plane) bow system for occlusal plane transfer in asymmetric ear position. MATERIALS AND METHODS: Two dentists participated in this study, one was categorized as Experimenter 1 and the other as Experimenter 2 based on their clinical experience with the facebow (1F, 2F) and POP bow (1P, 2P) systems. The vertical height difference between the two ears of the phantom model was set to 3 mm. Experimenter 1 and Experimenter 2 performed the facebow and POP bow systems on the phantom model 10 times each, and the transfer accuracy was analyzed. The accuracy was evaluated by measuring the angle between the reference virtual plane (RVP) of the phantom model and the experimental virtual plane (EVP) of the upper mounting plate through digital superimposition. All data were statistically analyzed using a paired t-test (P < .05). RESULTS: Regardless of clinical experience, the POP bow system (0.53° ± 0.30 (1P) and 0.19° ± 0.18 (2P) for Experimenter 1 and 2, respectively) was significantly more accurate than the facebow system (1.88° ± 0.50 (1F) and 1.34° ± 0.25 (2F), respectively) in the frontal view (P < .05). In the sagittal view, no significant differences were found between the POP bow system (0.92° ± 0.50 (1P) and 0.73° ± 0.42 (2P) for Experimenter 1 and 2, respectively) and the facebow system (0.82° ± 0.49 (1F) and 0.60° ± 0.39 (2F), respectively), regardless of clinical experience (P > .05). CONCLUSION: In cases of asymmetric ear position, the POP bow system may transfer occlusal plane information more accurately than the facebow system in the frontal view, regardless of clinical experience.
format Online
Article
Text
id pubmed-10625888
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-106258882023-11-07 In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position Kim, Dae-Sung Park, So-Hyung Ahn, Jong-Ju Jeong, Chang-Mo Yun, Mi-Jung Huh, Jung-Bo Lee, So-Hyoun J Adv Prosthodont Original Article PURPOSE: This in vitro study aimed to compare the accuracy of the conventional facebow system and the newly developed POP (PNUD (Pusan National University Dental School) Occlusal Plane) bow system for occlusal plane transfer in asymmetric ear position. MATERIALS AND METHODS: Two dentists participated in this study, one was categorized as Experimenter 1 and the other as Experimenter 2 based on their clinical experience with the facebow (1F, 2F) and POP bow (1P, 2P) systems. The vertical height difference between the two ears of the phantom model was set to 3 mm. Experimenter 1 and Experimenter 2 performed the facebow and POP bow systems on the phantom model 10 times each, and the transfer accuracy was analyzed. The accuracy was evaluated by measuring the angle between the reference virtual plane (RVP) of the phantom model and the experimental virtual plane (EVP) of the upper mounting plate through digital superimposition. All data were statistically analyzed using a paired t-test (P < .05). RESULTS: Regardless of clinical experience, the POP bow system (0.53° ± 0.30 (1P) and 0.19° ± 0.18 (2P) for Experimenter 1 and 2, respectively) was significantly more accurate than the facebow system (1.88° ± 0.50 (1F) and 1.34° ± 0.25 (2F), respectively) in the frontal view (P < .05). In the sagittal view, no significant differences were found between the POP bow system (0.92° ± 0.50 (1P) and 0.73° ± 0.42 (2P) for Experimenter 1 and 2, respectively) and the facebow system (0.82° ± 0.49 (1F) and 0.60° ± 0.39 (2F), respectively), regardless of clinical experience (P > .05). CONCLUSION: In cases of asymmetric ear position, the POP bow system may transfer occlusal plane information more accurately than the facebow system in the frontal view, regardless of clinical experience. The Korean Academy of Prosthodontics 2023-10 2023-10-26 /pmc/articles/PMC10625888/ /pubmed/37936837 http://dx.doi.org/10.4047/jap.2023.15.5.271 Text en © 2023 The Korean Academy of Prosthodontics https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Dae-Sung
Park, So-Hyung
Ahn, Jong-Ju
Jeong, Chang-Mo
Yun, Mi-Jung
Huh, Jung-Bo
Lee, So-Hyoun
In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position
title In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position
title_full In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position
title_fullStr In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position
title_full_unstemmed In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position
title_short In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position
title_sort in vitro comparison of the accuracy of an occlusal plane transfer method between facebow and pop bow systems in asymmetric ear position
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625888/
https://www.ncbi.nlm.nih.gov/pubmed/37936837
http://dx.doi.org/10.4047/jap.2023.15.5.271
work_keys_str_mv AT kimdaesung invitrocomparisonoftheaccuracyofanocclusalplanetransfermethodbetweenfacebowandpopbowsystemsinasymmetricearposition
AT parksohyung invitrocomparisonoftheaccuracyofanocclusalplanetransfermethodbetweenfacebowandpopbowsystemsinasymmetricearposition
AT ahnjongju invitrocomparisonoftheaccuracyofanocclusalplanetransfermethodbetweenfacebowandpopbowsystemsinasymmetricearposition
AT jeongchangmo invitrocomparisonoftheaccuracyofanocclusalplanetransfermethodbetweenfacebowandpopbowsystemsinasymmetricearposition
AT yunmijung invitrocomparisonoftheaccuracyofanocclusalplanetransfermethodbetweenfacebowandpopbowsystemsinasymmetricearposition
AT huhjungbo invitrocomparisonoftheaccuracyofanocclusalplanetransfermethodbetweenfacebowandpopbowsystemsinasymmetricearposition
AT leesohyoun invitrocomparisonoftheaccuracyofanocclusalplanetransfermethodbetweenfacebowandpopbowsystemsinasymmetricearposition