Direct wire pacing during measurement of fractional flow reserve: A randomized proof-of-concept noninferiority crossover trial

BACKGROUND: Adenosine administration for fractional flow reserve (FFR) measurement may induce heart pauses. AIMS: To assess the accuracy and tolerability of direct wire pacing (DWP) during measurement of FFR. METHODS: Adults with at least one intermediate coronary artery stenosis (40%–80%) were cons...

Descripción completa

Detalles Bibliográficos
Autores principales: Faurie, Benjamin, Acheampong, Angela, Abdellaoui, Mohamed, Dessus, Ilona, Monsegu, Jacques, Wintzer-Wehekind, Jérôme
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625906/
https://www.ncbi.nlm.nih.gov/pubmed/37937287
http://dx.doi.org/10.3389/fcvm.2023.1137309
_version_ 1785131229316644864
author Faurie, Benjamin
Acheampong, Angela
Abdellaoui, Mohamed
Dessus, Ilona
Monsegu, Jacques
Wintzer-Wehekind, Jérôme
author_facet Faurie, Benjamin
Acheampong, Angela
Abdellaoui, Mohamed
Dessus, Ilona
Monsegu, Jacques
Wintzer-Wehekind, Jérôme
author_sort Faurie, Benjamin
collection PubMed
description BACKGROUND: Adenosine administration for fractional flow reserve (FFR) measurement may induce heart pauses. AIMS: To assess the accuracy and tolerability of direct wire pacing (DWP) during measurement of FFR. METHODS: Adults with at least one intermediate coronary artery stenosis (40%–80%) were consecutively enrolled between June 2021 and February 2022 in this randomized, noninferiority, crossover trial (NCT04970082) carried out in France. DWP was applied (DWP) or not (standard method) through the pressure guidewire used for FFR measurement during adenosine-induced maximal hyperaemia. Subjects were randomly assigned to the allocation sequence (DWP first or standard first). A 2-minute washout period was observed between the two FFR measurements performed for each stenosis. The primary endpoint was the reproducibility of FFR measurements between methods. RESULTS: A total of 150 focal lesions, presented by 94 subjects, were randomized (ratio: 1:1). The FFR values obtained with each method were nearly identical (R = 0.98, p = 0.005). The mean FFR difference of 0.00054 (95% confidence interval: 0.004 to 0.003) showed the noninferiority of FFR measurement with DWP vs. that with the standard method. Higher levels of chest discomfort were reported with DWP than with the standard method (0.61 ± 0.84 vs. 1.05 ± 0.89, p < 0.001), and a correlation was observed between the electrical sensations reported with DWP and chest discomfort (p < 0.001). Pauses (n = 20/148 lesions) were observed with the standard method, but did not correlate with chest discomfort (p = 0.21). No pauses were observed with DWP. CONCLUSIONS: DWP during FFR measurement resulted in accurate and reproducible FFR values, and eliminated the pauses induced by adenosine.
format Online
Article
Text
id pubmed-10625906
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-106259062023-11-07 Direct wire pacing during measurement of fractional flow reserve: A randomized proof-of-concept noninferiority crossover trial Faurie, Benjamin Acheampong, Angela Abdellaoui, Mohamed Dessus, Ilona Monsegu, Jacques Wintzer-Wehekind, Jérôme Front Cardiovasc Med Cardiovascular Medicine BACKGROUND: Adenosine administration for fractional flow reserve (FFR) measurement may induce heart pauses. AIMS: To assess the accuracy and tolerability of direct wire pacing (DWP) during measurement of FFR. METHODS: Adults with at least one intermediate coronary artery stenosis (40%–80%) were consecutively enrolled between June 2021 and February 2022 in this randomized, noninferiority, crossover trial (NCT04970082) carried out in France. DWP was applied (DWP) or not (standard method) through the pressure guidewire used for FFR measurement during adenosine-induced maximal hyperaemia. Subjects were randomly assigned to the allocation sequence (DWP first or standard first). A 2-minute washout period was observed between the two FFR measurements performed for each stenosis. The primary endpoint was the reproducibility of FFR measurements between methods. RESULTS: A total of 150 focal lesions, presented by 94 subjects, were randomized (ratio: 1:1). The FFR values obtained with each method were nearly identical (R = 0.98, p = 0.005). The mean FFR difference of 0.00054 (95% confidence interval: 0.004 to 0.003) showed the noninferiority of FFR measurement with DWP vs. that with the standard method. Higher levels of chest discomfort were reported with DWP than with the standard method (0.61 ± 0.84 vs. 1.05 ± 0.89, p < 0.001), and a correlation was observed between the electrical sensations reported with DWP and chest discomfort (p < 0.001). Pauses (n = 20/148 lesions) were observed with the standard method, but did not correlate with chest discomfort (p = 0.21). No pauses were observed with DWP. CONCLUSIONS: DWP during FFR measurement resulted in accurate and reproducible FFR values, and eliminated the pauses induced by adenosine. Frontiers Media S.A. 2023-10-23 /pmc/articles/PMC10625906/ /pubmed/37937287 http://dx.doi.org/10.3389/fcvm.2023.1137309 Text en © 2023 Faurie, Acheampong, Abdellaoui, Dessus, Monsegu and Wintzer-Wehekind. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Faurie, Benjamin
Acheampong, Angela
Abdellaoui, Mohamed
Dessus, Ilona
Monsegu, Jacques
Wintzer-Wehekind, Jérôme
Direct wire pacing during measurement of fractional flow reserve: A randomized proof-of-concept noninferiority crossover trial
title Direct wire pacing during measurement of fractional flow reserve: A randomized proof-of-concept noninferiority crossover trial
title_full Direct wire pacing during measurement of fractional flow reserve: A randomized proof-of-concept noninferiority crossover trial
title_fullStr Direct wire pacing during measurement of fractional flow reserve: A randomized proof-of-concept noninferiority crossover trial
title_full_unstemmed Direct wire pacing during measurement of fractional flow reserve: A randomized proof-of-concept noninferiority crossover trial
title_short Direct wire pacing during measurement of fractional flow reserve: A randomized proof-of-concept noninferiority crossover trial
title_sort direct wire pacing during measurement of fractional flow reserve: a randomized proof-of-concept noninferiority crossover trial
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625906/
https://www.ncbi.nlm.nih.gov/pubmed/37937287
http://dx.doi.org/10.3389/fcvm.2023.1137309
work_keys_str_mv AT fauriebenjamin directwirepacingduringmeasurementoffractionalflowreservearandomizedproofofconceptnoninferioritycrossovertrial
AT acheampongangela directwirepacingduringmeasurementoffractionalflowreservearandomizedproofofconceptnoninferioritycrossovertrial
AT abdellaouimohamed directwirepacingduringmeasurementoffractionalflowreservearandomizedproofofconceptnoninferioritycrossovertrial
AT dessusilona directwirepacingduringmeasurementoffractionalflowreservearandomizedproofofconceptnoninferioritycrossovertrial
AT monsegujacques directwirepacingduringmeasurementoffractionalflowreservearandomizedproofofconceptnoninferioritycrossovertrial
AT wintzerwehekindjerome directwirepacingduringmeasurementoffractionalflowreservearandomizedproofofconceptnoninferioritycrossovertrial