Cargando…

Performance of a Nonlinear Magnetic Handheld Probe for Intraoperative Sentinel Lymph Node Detection: A Phantom Study

OBJECTIVE: This study investigates the performance of the DiffMag handheld probe (nonlinear magnetometry), to be used for sentinel lymph node detection. Furthermore, the performance of DiffMag is compared with a gamma probe and a first-order magnetometer (Sentimag(®), linear magnetometry). METHODS:...

Descripción completa

Detalles Bibliográficos
Autores principales: Nieuwenhuis, Eliane R., Mir, Nida, Horstman-van de Loosdrecht, Melissa M., Meeuwis, Antoi P. W., de Bakker, Maarten G. J., Scheenen, Tom W. J., Alic, Lejla
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625952/
https://www.ncbi.nlm.nih.gov/pubmed/37661223
http://dx.doi.org/10.1245/s10434-023-14166-z
_version_ 1785131240242806784
author Nieuwenhuis, Eliane R.
Mir, Nida
Horstman-van de Loosdrecht, Melissa M.
Meeuwis, Antoi P. W.
de Bakker, Maarten G. J.
Scheenen, Tom W. J.
Alic, Lejla
author_facet Nieuwenhuis, Eliane R.
Mir, Nida
Horstman-van de Loosdrecht, Melissa M.
Meeuwis, Antoi P. W.
de Bakker, Maarten G. J.
Scheenen, Tom W. J.
Alic, Lejla
author_sort Nieuwenhuis, Eliane R.
collection PubMed
description OBJECTIVE: This study investigates the performance of the DiffMag handheld probe (nonlinear magnetometry), to be used for sentinel lymph node detection. Furthermore, the performance of DiffMag is compared with a gamma probe and a first-order magnetometer (Sentimag(®), linear magnetometry). METHODS: The performance of all three probes was evaluated based on longitudinal distance, transverse distance, and resolving power for two tracer volumes. A phantom was developed to investigate the performance of the probes for a clinically relevant situation in the floor of the mouth (FOM). RESULTS: Considering the longitudinal distance, both DiffMag handheld and Sentimag(®) probe had comparable performance, while the gamma probe was able to detect at least a factor of 10 deeper. Transverse distances of 13, 11, and 51 mm were measured for the small tracer volume by the DiffMag handheld, Sentimag(®), and the gamma probe, respectively. For the large tracer volume this was 21, 18, and 55 mm, respectively. The full width at half maximum, at 7 mm probe height from the phantom surface, was 14, 12, and 18 mm for the small tracer volume and 15, 18, and 25 mm for the large tracer volume with the DiffMag handheld, Sentimag(®), and gamma probe, respectively. CONCLUSIONS: With a high resolving power but limited longitudinal distance, the DiffMag handheld probe seems suitable for detecting SLNs which are in close proximity to the primary tumor. In this study, comparable results were shown using linear magnetometry. The gamma probe reached 10 times deeper, but has a lower resolving power compared with the DiffMag handheld probe.
format Online
Article
Text
id pubmed-10625952
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-106259522023-11-07 Performance of a Nonlinear Magnetic Handheld Probe for Intraoperative Sentinel Lymph Node Detection: A Phantom Study Nieuwenhuis, Eliane R. Mir, Nida Horstman-van de Loosdrecht, Melissa M. Meeuwis, Antoi P. W. de Bakker, Maarten G. J. Scheenen, Tom W. J. Alic, Lejla Ann Surg Oncol Translational Research OBJECTIVE: This study investigates the performance of the DiffMag handheld probe (nonlinear magnetometry), to be used for sentinel lymph node detection. Furthermore, the performance of DiffMag is compared with a gamma probe and a first-order magnetometer (Sentimag(®), linear magnetometry). METHODS: The performance of all three probes was evaluated based on longitudinal distance, transverse distance, and resolving power for two tracer volumes. A phantom was developed to investigate the performance of the probes for a clinically relevant situation in the floor of the mouth (FOM). RESULTS: Considering the longitudinal distance, both DiffMag handheld and Sentimag(®) probe had comparable performance, while the gamma probe was able to detect at least a factor of 10 deeper. Transverse distances of 13, 11, and 51 mm were measured for the small tracer volume by the DiffMag handheld, Sentimag(®), and the gamma probe, respectively. For the large tracer volume this was 21, 18, and 55 mm, respectively. The full width at half maximum, at 7 mm probe height from the phantom surface, was 14, 12, and 18 mm for the small tracer volume and 15, 18, and 25 mm for the large tracer volume with the DiffMag handheld, Sentimag(®), and gamma probe, respectively. CONCLUSIONS: With a high resolving power but limited longitudinal distance, the DiffMag handheld probe seems suitable for detecting SLNs which are in close proximity to the primary tumor. In this study, comparable results were shown using linear magnetometry. The gamma probe reached 10 times deeper, but has a lower resolving power compared with the DiffMag handheld probe. Springer International Publishing 2023-09-04 2023 /pmc/articles/PMC10625952/ /pubmed/37661223 http://dx.doi.org/10.1245/s10434-023-14166-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Translational Research
Nieuwenhuis, Eliane R.
Mir, Nida
Horstman-van de Loosdrecht, Melissa M.
Meeuwis, Antoi P. W.
de Bakker, Maarten G. J.
Scheenen, Tom W. J.
Alic, Lejla
Performance of a Nonlinear Magnetic Handheld Probe for Intraoperative Sentinel Lymph Node Detection: A Phantom Study
title Performance of a Nonlinear Magnetic Handheld Probe for Intraoperative Sentinel Lymph Node Detection: A Phantom Study
title_full Performance of a Nonlinear Magnetic Handheld Probe for Intraoperative Sentinel Lymph Node Detection: A Phantom Study
title_fullStr Performance of a Nonlinear Magnetic Handheld Probe for Intraoperative Sentinel Lymph Node Detection: A Phantom Study
title_full_unstemmed Performance of a Nonlinear Magnetic Handheld Probe for Intraoperative Sentinel Lymph Node Detection: A Phantom Study
title_short Performance of a Nonlinear Magnetic Handheld Probe for Intraoperative Sentinel Lymph Node Detection: A Phantom Study
title_sort performance of a nonlinear magnetic handheld probe for intraoperative sentinel lymph node detection: a phantom study
topic Translational Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625952/
https://www.ncbi.nlm.nih.gov/pubmed/37661223
http://dx.doi.org/10.1245/s10434-023-14166-z
work_keys_str_mv AT nieuwenhuiselianer performanceofanonlinearmagnetichandheldprobeforintraoperativesentinellymphnodedetectionaphantomstudy
AT mirnida performanceofanonlinearmagnetichandheldprobeforintraoperativesentinellymphnodedetectionaphantomstudy
AT horstmanvandeloosdrechtmelissam performanceofanonlinearmagnetichandheldprobeforintraoperativesentinellymphnodedetectionaphantomstudy
AT meeuwisantoipw performanceofanonlinearmagnetichandheldprobeforintraoperativesentinellymphnodedetectionaphantomstudy
AT debakkermaartengj performanceofanonlinearmagnetichandheldprobeforintraoperativesentinellymphnodedetectionaphantomstudy
AT scheenentomwj performanceofanonlinearmagnetichandheldprobeforintraoperativesentinellymphnodedetectionaphantomstudy
AT aliclejla performanceofanonlinearmagnetichandheldprobeforintraoperativesentinellymphnodedetectionaphantomstudy