Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping automated endothelial keratoplasty: a meta-analysis
AIMS: This study aims to compare the clinical outcome of Descemet membrane endothelial keratoplasty (DMEK) and ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) in patients with corneal endothelial dysfunction due to Fuchs’ endothelial dystrophy or pseudophakic bullous kerat...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10626808/ https://www.ncbi.nlm.nih.gov/pubmed/37914389 http://dx.doi.org/10.1136/bmjophth-2023-001397 |
_version_ | 1785131416707661824 |
---|---|
author | Sela, Tal Corina Iflah, Moti Muhsen, Khitam Zahavi, Alon |
author_facet | Sela, Tal Corina Iflah, Moti Muhsen, Khitam Zahavi, Alon |
author_sort | Sela, Tal Corina |
collection | PubMed |
description | AIMS: This study aims to compare the clinical outcome of Descemet membrane endothelial keratoplasty (DMEK) and ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) in patients with corneal endothelial dysfunction due to Fuchs’ endothelial dystrophy or pseudophakic bullous keratopathy. METHODS: We conducted a meta-analysis using a literature search of Embase, PubMed, Cochrane CENTRAL, ClinicalTrials.gov and WHO ICTRP databases. We included randomised controlled trials (RCTs) and cohort studies that compared DMEK and UT-DSAEK (graft<130 µm), with a follow-up of ≥12 months, published until 20 February 2022. We used the Revised Cochrane risk-of-bias tool for RCTs and the Risk of Bias in Non-Randomised Studies-of Interventions system for cohort studies. RESULTS: Out of 144 records, 8 studies (3 RCTs, 2 fellow-eye studies and 3 cohort studies) were included, encompassing 376 eyes, (N=187 DMEK vs N=189 UT-DSAEK). The 12-month logarithm of the minimum angle of resolution best-corrected visual acuity (BCVA) was better post-DMEK (mean difference −0.06 (95% CI −0.10 to –0.02)), but with higher rebubbling risk: OR 2.76 (95% CI 1.46 to 5.22). Heterogeneity was significant I(2)=57%. Findings were consistent when excluding retrospective studies, including only studies with low risk of bias or RCTs only. An analysis of studies with mean DSAEK grafts <70 µm showed no significant difference in BCVA between the procedures. Publication bias was found in the BCVA analysis (Egger’s test p=0.023). CONCLUSIONS: Post-DMEK BCVA is superior to post-UT-DSAEK when using <130 µm grafts. DSAEK grafts <70 µm may not significantly differ from DMEK. The higher risk of rebubbling with DMEK necessitates an appropriate selection of patients. PROSPERO REGISTRATION NUMBER: CRD42022340805. |
format | Online Article Text |
id | pubmed-10626808 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-106268082023-11-07 Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping automated endothelial keratoplasty: a meta-analysis Sela, Tal Corina Iflah, Moti Muhsen, Khitam Zahavi, Alon BMJ Open Ophthalmol Cornea and Ocular Surface AIMS: This study aims to compare the clinical outcome of Descemet membrane endothelial keratoplasty (DMEK) and ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) in patients with corneal endothelial dysfunction due to Fuchs’ endothelial dystrophy or pseudophakic bullous keratopathy. METHODS: We conducted a meta-analysis using a literature search of Embase, PubMed, Cochrane CENTRAL, ClinicalTrials.gov and WHO ICTRP databases. We included randomised controlled trials (RCTs) and cohort studies that compared DMEK and UT-DSAEK (graft<130 µm), with a follow-up of ≥12 months, published until 20 February 2022. We used the Revised Cochrane risk-of-bias tool for RCTs and the Risk of Bias in Non-Randomised Studies-of Interventions system for cohort studies. RESULTS: Out of 144 records, 8 studies (3 RCTs, 2 fellow-eye studies and 3 cohort studies) were included, encompassing 376 eyes, (N=187 DMEK vs N=189 UT-DSAEK). The 12-month logarithm of the minimum angle of resolution best-corrected visual acuity (BCVA) was better post-DMEK (mean difference −0.06 (95% CI −0.10 to –0.02)), but with higher rebubbling risk: OR 2.76 (95% CI 1.46 to 5.22). Heterogeneity was significant I(2)=57%. Findings were consistent when excluding retrospective studies, including only studies with low risk of bias or RCTs only. An analysis of studies with mean DSAEK grafts <70 µm showed no significant difference in BCVA between the procedures. Publication bias was found in the BCVA analysis (Egger’s test p=0.023). CONCLUSIONS: Post-DMEK BCVA is superior to post-UT-DSAEK when using <130 µm grafts. DSAEK grafts <70 µm may not significantly differ from DMEK. The higher risk of rebubbling with DMEK necessitates an appropriate selection of patients. PROSPERO REGISTRATION NUMBER: CRD42022340805. BMJ Publishing Group 2023-11-01 /pmc/articles/PMC10626808/ /pubmed/37914389 http://dx.doi.org/10.1136/bmjophth-2023-001397 Text en © Author(s) (or their employer(s)) 2023. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) . |
spellingShingle | Cornea and Ocular Surface Sela, Tal Corina Iflah, Moti Muhsen, Khitam Zahavi, Alon Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping automated endothelial keratoplasty: a meta-analysis |
title | Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping automated endothelial keratoplasty: a meta-analysis |
title_full | Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping automated endothelial keratoplasty: a meta-analysis |
title_fullStr | Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping automated endothelial keratoplasty: a meta-analysis |
title_full_unstemmed | Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping automated endothelial keratoplasty: a meta-analysis |
title_short | Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping automated endothelial keratoplasty: a meta-analysis |
title_sort | descemet membrane endothelial keratoplasty compared with ultrathin descemet stripping automated endothelial keratoplasty: a meta-analysis |
topic | Cornea and Ocular Surface |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10626808/ https://www.ncbi.nlm.nih.gov/pubmed/37914389 http://dx.doi.org/10.1136/bmjophth-2023-001397 |
work_keys_str_mv | AT selatalcorina descemetmembraneendothelialkeratoplastycomparedwithultrathindescemetstrippingautomatedendothelialkeratoplastyametaanalysis AT iflahmoti descemetmembraneendothelialkeratoplastycomparedwithultrathindescemetstrippingautomatedendothelialkeratoplastyametaanalysis AT muhsenkhitam descemetmembraneendothelialkeratoplastycomparedwithultrathindescemetstrippingautomatedendothelialkeratoplastyametaanalysis AT zahavialon descemetmembraneendothelialkeratoplastycomparedwithultrathindescemetstrippingautomatedendothelialkeratoplastyametaanalysis |