Cargando…
Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study
PURPOSE: The purpose of this study was to evaluate the relationship between peripheral defocus and pupil size on axial growth in children randomly assigned to wear either single vision contact lenses, +1.50 diopter (D), or +2.50 D addition multifocal contact lenses (MFCLs). METHODS: Children 7 to 11...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627291/ https://www.ncbi.nlm.nih.gov/pubmed/37910092 http://dx.doi.org/10.1167/iovs.64.14.3 |
_version_ | 1785131508190674944 |
---|---|
author | Berntsen, David A. Ticak, Anita Sinnott, Loraine T. Chandler, Moriah A. Jones, Jenny Huang Morrison, Ann Jones-Jordan, Lisa A. Walline, Jeffrey J. Mutti, Donald O. |
author_facet | Berntsen, David A. Ticak, Anita Sinnott, Loraine T. Chandler, Moriah A. Jones, Jenny Huang Morrison, Ann Jones-Jordan, Lisa A. Walline, Jeffrey J. Mutti, Donald O. |
author_sort | Berntsen, David A. |
collection | PubMed |
description | PURPOSE: The purpose of this study was to evaluate the relationship between peripheral defocus and pupil size on axial growth in children randomly assigned to wear either single vision contact lenses, +1.50 diopter (D), or +2.50 D addition multifocal contact lenses (MFCLs). METHODS: Children 7 to 11 years old with myopia (−0.75 to −5.00 D; spherical component) and ≤1.00 D astigmatism were enrolled. Autorefraction (horizontal meridian; right eye) was measured annually wearing contact lenses centrally and ±20 degrees, ±30 degrees, and ±40 degrees from the line of sight at near and distance. Photopic and mesopic pupil size were measured. The effects of peripheral defocus, treatment group, and pupil size on the 3-year change in axial length were modeled using multiple variables that evaluated defocus across the retina. RESULTS: Although several peripheral defocus variables were associated with slower axial growth with MFCLs, they were either no longer significant or not meaningfully associated with eye growth after the treatment group was included in the model. The treatment group assignment better explained the slower eye growth with +2.50 MFCLs than peripheral defocus. Photopic and mesopic pupil size did not modify eye growth with the +2.50 MFCL (all P ≥ 0.37). CONCLUSIONS: The optical signal causing slower axial elongation with +2.50 MFCLs is better explained by the lens type worn than by peripheral defocus. The signal might be something other than peripheral defocus, or there is not a linear dose-response relationship within treatment groups. We found no evidence to support pupil size as a criterion when deciding which myopic children to treat with MFCLs. |
format | Online Article Text |
id | pubmed-10627291 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-106272912023-11-07 Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study Berntsen, David A. Ticak, Anita Sinnott, Loraine T. Chandler, Moriah A. Jones, Jenny Huang Morrison, Ann Jones-Jordan, Lisa A. Walline, Jeffrey J. Mutti, Donald O. Invest Ophthalmol Vis Sci Clinical and Epidemiologic Research PURPOSE: The purpose of this study was to evaluate the relationship between peripheral defocus and pupil size on axial growth in children randomly assigned to wear either single vision contact lenses, +1.50 diopter (D), or +2.50 D addition multifocal contact lenses (MFCLs). METHODS: Children 7 to 11 years old with myopia (−0.75 to −5.00 D; spherical component) and ≤1.00 D astigmatism were enrolled. Autorefraction (horizontal meridian; right eye) was measured annually wearing contact lenses centrally and ±20 degrees, ±30 degrees, and ±40 degrees from the line of sight at near and distance. Photopic and mesopic pupil size were measured. The effects of peripheral defocus, treatment group, and pupil size on the 3-year change in axial length were modeled using multiple variables that evaluated defocus across the retina. RESULTS: Although several peripheral defocus variables were associated with slower axial growth with MFCLs, they were either no longer significant or not meaningfully associated with eye growth after the treatment group was included in the model. The treatment group assignment better explained the slower eye growth with +2.50 MFCLs than peripheral defocus. Photopic and mesopic pupil size did not modify eye growth with the +2.50 MFCL (all P ≥ 0.37). CONCLUSIONS: The optical signal causing slower axial elongation with +2.50 MFCLs is better explained by the lens type worn than by peripheral defocus. The signal might be something other than peripheral defocus, or there is not a linear dose-response relationship within treatment groups. We found no evidence to support pupil size as a criterion when deciding which myopic children to treat with MFCLs. The Association for Research in Vision and Ophthalmology 2023-11-01 /pmc/articles/PMC10627291/ /pubmed/37910092 http://dx.doi.org/10.1167/iovs.64.14.3 Text en Copyright 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Clinical and Epidemiologic Research Berntsen, David A. Ticak, Anita Sinnott, Loraine T. Chandler, Moriah A. Jones, Jenny Huang Morrison, Ann Jones-Jordan, Lisa A. Walline, Jeffrey J. Mutti, Donald O. Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study |
title | Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study |
title_full | Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study |
title_fullStr | Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study |
title_full_unstemmed | Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study |
title_short | Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study |
title_sort | peripheral defocus, pupil size, and axial eye growth in children wearing soft multifocal contact lenses in the blink study |
topic | Clinical and Epidemiologic Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627291/ https://www.ncbi.nlm.nih.gov/pubmed/37910092 http://dx.doi.org/10.1167/iovs.64.14.3 |
work_keys_str_mv | AT berntsendavida peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy AT ticakanita peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy AT sinnottlorainet peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy AT chandlermoriaha peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy AT jonesjennyhuang peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy AT morrisonann peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy AT jonesjordanlisaa peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy AT wallinejeffreyj peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy AT muttidonaldo peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy AT peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy |