Cargando…

Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study

PURPOSE: The purpose of this study was to evaluate the relationship between peripheral defocus and pupil size on axial growth in children randomly assigned to wear either single vision contact lenses, +1.50 diopter (D), or +2.50 D addition multifocal contact lenses (MFCLs). METHODS: Children 7 to 11...

Descripción completa

Detalles Bibliográficos
Autores principales: Berntsen, David A., Ticak, Anita, Sinnott, Loraine T., Chandler, Moriah A., Jones, Jenny Huang, Morrison, Ann, Jones-Jordan, Lisa A., Walline, Jeffrey J., Mutti, Donald O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627291/
https://www.ncbi.nlm.nih.gov/pubmed/37910092
http://dx.doi.org/10.1167/iovs.64.14.3
_version_ 1785131508190674944
author Berntsen, David A.
Ticak, Anita
Sinnott, Loraine T.
Chandler, Moriah A.
Jones, Jenny Huang
Morrison, Ann
Jones-Jordan, Lisa A.
Walline, Jeffrey J.
Mutti, Donald O.
author_facet Berntsen, David A.
Ticak, Anita
Sinnott, Loraine T.
Chandler, Moriah A.
Jones, Jenny Huang
Morrison, Ann
Jones-Jordan, Lisa A.
Walline, Jeffrey J.
Mutti, Donald O.
author_sort Berntsen, David A.
collection PubMed
description PURPOSE: The purpose of this study was to evaluate the relationship between peripheral defocus and pupil size on axial growth in children randomly assigned to wear either single vision contact lenses, +1.50 diopter (D), or +2.50 D addition multifocal contact lenses (MFCLs). METHODS: Children 7 to 11 years old with myopia (−0.75 to −5.00 D; spherical component) and ≤1.00 D astigmatism were enrolled. Autorefraction (horizontal meridian; right eye) was measured annually wearing contact lenses centrally and ±20 degrees, ±30 degrees, and ±40 degrees from the line of sight at near and distance. Photopic and mesopic pupil size were measured. The effects of peripheral defocus, treatment group, and pupil size on the 3-year change in axial length were modeled using multiple variables that evaluated defocus across the retina. RESULTS: Although several peripheral defocus variables were associated with slower axial growth with MFCLs, they were either no longer significant or not meaningfully associated with eye growth after the treatment group was included in the model. The treatment group assignment better explained the slower eye growth with +2.50 MFCLs than peripheral defocus. Photopic and mesopic pupil size did not modify eye growth with the +2.50 MFCL (all P ≥ 0.37). CONCLUSIONS: The optical signal causing slower axial elongation with +2.50 MFCLs is better explained by the lens type worn than by peripheral defocus. The signal might be something other than peripheral defocus, or there is not a linear dose-response relationship within treatment groups. We found no evidence to support pupil size as a criterion when deciding which myopic children to treat with MFCLs.
format Online
Article
Text
id pubmed-10627291
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-106272912023-11-07 Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study Berntsen, David A. Ticak, Anita Sinnott, Loraine T. Chandler, Moriah A. Jones, Jenny Huang Morrison, Ann Jones-Jordan, Lisa A. Walline, Jeffrey J. Mutti, Donald O. Invest Ophthalmol Vis Sci Clinical and Epidemiologic Research PURPOSE: The purpose of this study was to evaluate the relationship between peripheral defocus and pupil size on axial growth in children randomly assigned to wear either single vision contact lenses, +1.50 diopter (D), or +2.50 D addition multifocal contact lenses (MFCLs). METHODS: Children 7 to 11 years old with myopia (−0.75 to −5.00 D; spherical component) and ≤1.00 D astigmatism were enrolled. Autorefraction (horizontal meridian; right eye) was measured annually wearing contact lenses centrally and ±20 degrees, ±30 degrees, and ±40 degrees from the line of sight at near and distance. Photopic and mesopic pupil size were measured. The effects of peripheral defocus, treatment group, and pupil size on the 3-year change in axial length were modeled using multiple variables that evaluated defocus across the retina. RESULTS: Although several peripheral defocus variables were associated with slower axial growth with MFCLs, they were either no longer significant or not meaningfully associated with eye growth after the treatment group was included in the model. The treatment group assignment better explained the slower eye growth with +2.50 MFCLs than peripheral defocus. Photopic and mesopic pupil size did not modify eye growth with the +2.50 MFCL (all P ≥ 0.37). CONCLUSIONS: The optical signal causing slower axial elongation with +2.50 MFCLs is better explained by the lens type worn than by peripheral defocus. The signal might be something other than peripheral defocus, or there is not a linear dose-response relationship within treatment groups. We found no evidence to support pupil size as a criterion when deciding which myopic children to treat with MFCLs. The Association for Research in Vision and Ophthalmology 2023-11-01 /pmc/articles/PMC10627291/ /pubmed/37910092 http://dx.doi.org/10.1167/iovs.64.14.3 Text en Copyright 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Clinical and Epidemiologic Research
Berntsen, David A.
Ticak, Anita
Sinnott, Loraine T.
Chandler, Moriah A.
Jones, Jenny Huang
Morrison, Ann
Jones-Jordan, Lisa A.
Walline, Jeffrey J.
Mutti, Donald O.
Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study
title Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study
title_full Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study
title_fullStr Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study
title_full_unstemmed Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study
title_short Peripheral Defocus, Pupil Size, and Axial Eye Growth in Children Wearing Soft Multifocal Contact Lenses in the BLINK Study
title_sort peripheral defocus, pupil size, and axial eye growth in children wearing soft multifocal contact lenses in the blink study
topic Clinical and Epidemiologic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627291/
https://www.ncbi.nlm.nih.gov/pubmed/37910092
http://dx.doi.org/10.1167/iovs.64.14.3
work_keys_str_mv AT berntsendavida peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy
AT ticakanita peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy
AT sinnottlorainet peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy
AT chandlermoriaha peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy
AT jonesjennyhuang peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy
AT morrisonann peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy
AT jonesjordanlisaa peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy
AT wallinejeffreyj peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy
AT muttidonaldo peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy
AT peripheraldefocuspupilsizeandaxialeyegrowthinchildrenwearingsoftmultifocalcontactlensesintheblinkstudy