Cargando…
The Value of Left Internal Mammary Artery Flow Velocity in Predicting the Prognosis of Patients After Coronary Artery Bypass Grafting
BACKGROUND: The purpose of this study was to explore the value of the left internal mammary artery flow velocity (LIMAV) measured by ultrasound before coronary artery bypass grafting (CABG) in predicting the prognosis of patients after left internal mammary artery (LIMA) bypass grafting. METHODS: On...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elmer Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627374/ https://www.ncbi.nlm.nih.gov/pubmed/37936630 http://dx.doi.org/10.14740/cr1566 |
_version_ | 1785131520431751168 |
---|---|
author | Guo, Feng Wei Chen, Hong Dong, Ya Ling Shang, Jia Nan Ruan, Li Tao Yan, Yang Song, Yan |
author_facet | Guo, Feng Wei Chen, Hong Dong, Ya Ling Shang, Jia Nan Ruan, Li Tao Yan, Yang Song, Yan |
author_sort | Guo, Feng Wei |
collection | PubMed |
description | BACKGROUND: The purpose of this study was to explore the value of the left internal mammary artery flow velocity (LIMAV) measured by ultrasound before coronary artery bypass grafting (CABG) in predicting the prognosis of patients after left internal mammary artery (LIMA) bypass grafting. METHODS: One hundred and four patients who underwent CABG with LIMA as the bridge vessel in the cardiovascular surgery department of our hospital between May 2018 and June 2019 were selected. All patients underwent transthoracic Doppler ultrasonography to measure LIMAV preoperatively. Intraoperatively, mean graft flow (MGF) and pulsatility index (PI) of the LIMA bridge were measured using transit time flow measurement (TTFM). The primary endpoint event in this study was cardiac death within 18 months after surgery. RESULTS: The Cox survival analysis showed that the MGF, the LIMAV and left ventricular ejection fraction (LVEF) were risk factors for death after CABG. The cut-offs of MGF, LIMAV and LVEF for the prediction of death after CABG were ≤ 14 mL/min (area under the curve (AUC): 0.830; sensitivity: 100%; specificity: 65.6%), ≤ 60 cm/s (AUC: 0.759; sensitivity: 65.5%; specificity: 85.3%), and ≤ 44% (AUC: 0.724; sensitivity: 50%; specificity: 88.5%), respectively. Compared with the use of MGF, MGF + LIMAV, combination of the MGF + LIMAV + LVEF (AUC: 0.929; sensitivity: 100%; specificity: 81.1%) resulted in a stronger predictive value (MGF vs. MGF + LIMAV + LVEF: P = 0.02). CONCLUSION: LIMAV measured by preoperative transthoracic ultrasound combined with intraoperative MGF and LVEF may have a greater value in predicting patients’ risk of cardiac death after CABG. |
format | Online Article Text |
id | pubmed-10627374 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elmer Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-106273742023-11-07 The Value of Left Internal Mammary Artery Flow Velocity in Predicting the Prognosis of Patients After Coronary Artery Bypass Grafting Guo, Feng Wei Chen, Hong Dong, Ya Ling Shang, Jia Nan Ruan, Li Tao Yan, Yang Song, Yan Cardiol Res Original Article BACKGROUND: The purpose of this study was to explore the value of the left internal mammary artery flow velocity (LIMAV) measured by ultrasound before coronary artery bypass grafting (CABG) in predicting the prognosis of patients after left internal mammary artery (LIMA) bypass grafting. METHODS: One hundred and four patients who underwent CABG with LIMA as the bridge vessel in the cardiovascular surgery department of our hospital between May 2018 and June 2019 were selected. All patients underwent transthoracic Doppler ultrasonography to measure LIMAV preoperatively. Intraoperatively, mean graft flow (MGF) and pulsatility index (PI) of the LIMA bridge were measured using transit time flow measurement (TTFM). The primary endpoint event in this study was cardiac death within 18 months after surgery. RESULTS: The Cox survival analysis showed that the MGF, the LIMAV and left ventricular ejection fraction (LVEF) were risk factors for death after CABG. The cut-offs of MGF, LIMAV and LVEF for the prediction of death after CABG were ≤ 14 mL/min (area under the curve (AUC): 0.830; sensitivity: 100%; specificity: 65.6%), ≤ 60 cm/s (AUC: 0.759; sensitivity: 65.5%; specificity: 85.3%), and ≤ 44% (AUC: 0.724; sensitivity: 50%; specificity: 88.5%), respectively. Compared with the use of MGF, MGF + LIMAV, combination of the MGF + LIMAV + LVEF (AUC: 0.929; sensitivity: 100%; specificity: 81.1%) resulted in a stronger predictive value (MGF vs. MGF + LIMAV + LVEF: P = 0.02). CONCLUSION: LIMAV measured by preoperative transthoracic ultrasound combined with intraoperative MGF and LVEF may have a greater value in predicting patients’ risk of cardiac death after CABG. Elmer Press 2023-10 2023-10-21 /pmc/articles/PMC10627374/ /pubmed/37936630 http://dx.doi.org/10.14740/cr1566 Text en Copyright 2023, Guo et al. https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Guo, Feng Wei Chen, Hong Dong, Ya Ling Shang, Jia Nan Ruan, Li Tao Yan, Yang Song, Yan The Value of Left Internal Mammary Artery Flow Velocity in Predicting the Prognosis of Patients After Coronary Artery Bypass Grafting |
title | The Value of Left Internal Mammary Artery Flow Velocity in Predicting the Prognosis of Patients After Coronary Artery Bypass Grafting |
title_full | The Value of Left Internal Mammary Artery Flow Velocity in Predicting the Prognosis of Patients After Coronary Artery Bypass Grafting |
title_fullStr | The Value of Left Internal Mammary Artery Flow Velocity in Predicting the Prognosis of Patients After Coronary Artery Bypass Grafting |
title_full_unstemmed | The Value of Left Internal Mammary Artery Flow Velocity in Predicting the Prognosis of Patients After Coronary Artery Bypass Grafting |
title_short | The Value of Left Internal Mammary Artery Flow Velocity in Predicting the Prognosis of Patients After Coronary Artery Bypass Grafting |
title_sort | value of left internal mammary artery flow velocity in predicting the prognosis of patients after coronary artery bypass grafting |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627374/ https://www.ncbi.nlm.nih.gov/pubmed/37936630 http://dx.doi.org/10.14740/cr1566 |
work_keys_str_mv | AT guofengwei thevalueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting AT chenhong thevalueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting AT dongyaling thevalueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting AT shangjianan thevalueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting AT ruanlitao thevalueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting AT yanyang thevalueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting AT songyan thevalueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting AT guofengwei valueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting AT chenhong valueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting AT dongyaling valueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting AT shangjianan valueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting AT ruanlitao valueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting AT yanyang valueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting AT songyan valueofleftinternalmammaryarteryflowvelocityinpredictingtheprognosisofpatientsaftercoronaryarterybypassgrafting |