Cargando…

Long-Term Assessment of Thin-Strut BioMime Coronary Stent System in Real-World Population at Single-Center: A Retrospective Observational Study

BACKGROUND: The short-term clinical outcomes of first-generation thicker-strut durable polymer-based drug-eluting stents (DES) have been widely examined. However, there is a scarcity on qualitative research on the long-term usage of DES that evaluated the thinner strut biodegradable stents for coron...

Descripción completa

Detalles Bibliográficos
Autores principales: Meennahalli Palleda, Girish, Gupta, Mohit, Bansal, Ankit, Batra, Vishal, Tyagi, Sanjay, Kunal, Shekhar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elmer Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627375/
https://www.ncbi.nlm.nih.gov/pubmed/37936627
http://dx.doi.org/10.14740/cr1515
_version_ 1785131520662437888
author Meennahalli Palleda, Girish
Gupta, Mohit
Bansal, Ankit
Batra, Vishal
Tyagi, Sanjay
Kunal, Shekhar
author_facet Meennahalli Palleda, Girish
Gupta, Mohit
Bansal, Ankit
Batra, Vishal
Tyagi, Sanjay
Kunal, Shekhar
author_sort Meennahalli Palleda, Girish
collection PubMed
description BACKGROUND: The short-term clinical outcomes of first-generation thicker-strut durable polymer-based drug-eluting stents (DES) have been widely examined. However, there is a scarcity on qualitative research on the long-term usage of DES that evaluated the thinner strut biodegradable stents for coronary artery disease. Hence, we sought to investigate the long-term safety and performance of thinner strut biodegradable polymer-based BioMime sirolimus-eluting coronary stent system in real-world patients with symptomatic ischemic heart disease. METHODS: This was a retrospective, observational, single-center, post-marketing clinical follow-up study. The primary endpoints were the incidence of major adverse cardiac events (MACE), defined as a composite of cardiac death, myocardial infarction (MI) attributed to target vessel revascularization (TVR), and target lesion revascularization (TLR) at 1-, 2-, 3- and 4-year follow-ups. The secondary endpoints were cardiac death, MI, TLR, TVR, device and procedural success rates, and stent thrombosis (ST). RESULTS: In all, 1,188 consecutive patients were enrolled, and 1,333 (1,257 de novo and 76 in-stent restenotic lesions) out of 1,565 lesions were treated with the study device. The mean age of patients was 53.26 ± 10.31 years and 86.2% were male. The quantitative coronary angiographic derived mean lesion length and diameter were 29.62 ± 9.62 mm and 3.01 ± 0.29 mm, respectively. The average length and diameter of the study device implanted were 30.89 ± 6.31 mm and 3.17 ± 0.25 mm, respectively. The cumulative incidence of MACE at 1-, 2-, 3-, and 4 years was 0.61%, 1.47%, 2.08%, and 3.40%, respectively, and cumulative deaths due to cardiac causes were 0.61%, 1.13%, 1.22%, and 1.83%, respectively. There were no cases of TLR or TVR at 1-year follow-up. The cumulative rate of TLR at 2-, 3-, and 4 years was 0.35%, 0.87%, and 1.57%, respectively, while that of TVR was 0.61%, 1.47%, and 2.35%, respectively. Three (0.3%) incidences of probable ST occurred during the 6-month follow-up; no new cases were reported further. In subgroup analysis, MACEs were comparable across the long- and short-length stent groups through 4-year follow-up. CONCLUSIONS: This long-term study demonstrates the safety and performance of the ultra-thin BioMime sirolimus-eluting stent with satisfactory clinical outcomes in patients with symptomatic ischemic heart disease in real-world scenario.
format Online
Article
Text
id pubmed-10627375
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elmer Press
record_format MEDLINE/PubMed
spelling pubmed-106273752023-11-07 Long-Term Assessment of Thin-Strut BioMime Coronary Stent System in Real-World Population at Single-Center: A Retrospective Observational Study Meennahalli Palleda, Girish Gupta, Mohit Bansal, Ankit Batra, Vishal Tyagi, Sanjay Kunal, Shekhar Cardiol Res Original Article BACKGROUND: The short-term clinical outcomes of first-generation thicker-strut durable polymer-based drug-eluting stents (DES) have been widely examined. However, there is a scarcity on qualitative research on the long-term usage of DES that evaluated the thinner strut biodegradable stents for coronary artery disease. Hence, we sought to investigate the long-term safety and performance of thinner strut biodegradable polymer-based BioMime sirolimus-eluting coronary stent system in real-world patients with symptomatic ischemic heart disease. METHODS: This was a retrospective, observational, single-center, post-marketing clinical follow-up study. The primary endpoints were the incidence of major adverse cardiac events (MACE), defined as a composite of cardiac death, myocardial infarction (MI) attributed to target vessel revascularization (TVR), and target lesion revascularization (TLR) at 1-, 2-, 3- and 4-year follow-ups. The secondary endpoints were cardiac death, MI, TLR, TVR, device and procedural success rates, and stent thrombosis (ST). RESULTS: In all, 1,188 consecutive patients were enrolled, and 1,333 (1,257 de novo and 76 in-stent restenotic lesions) out of 1,565 lesions were treated with the study device. The mean age of patients was 53.26 ± 10.31 years and 86.2% were male. The quantitative coronary angiographic derived mean lesion length and diameter were 29.62 ± 9.62 mm and 3.01 ± 0.29 mm, respectively. The average length and diameter of the study device implanted were 30.89 ± 6.31 mm and 3.17 ± 0.25 mm, respectively. The cumulative incidence of MACE at 1-, 2-, 3-, and 4 years was 0.61%, 1.47%, 2.08%, and 3.40%, respectively, and cumulative deaths due to cardiac causes were 0.61%, 1.13%, 1.22%, and 1.83%, respectively. There were no cases of TLR or TVR at 1-year follow-up. The cumulative rate of TLR at 2-, 3-, and 4 years was 0.35%, 0.87%, and 1.57%, respectively, while that of TVR was 0.61%, 1.47%, and 2.35%, respectively. Three (0.3%) incidences of probable ST occurred during the 6-month follow-up; no new cases were reported further. In subgroup analysis, MACEs were comparable across the long- and short-length stent groups through 4-year follow-up. CONCLUSIONS: This long-term study demonstrates the safety and performance of the ultra-thin BioMime sirolimus-eluting stent with satisfactory clinical outcomes in patients with symptomatic ischemic heart disease in real-world scenario. Elmer Press 2023-10 2023-10-21 /pmc/articles/PMC10627375/ /pubmed/37936627 http://dx.doi.org/10.14740/cr1515 Text en Copyright 2023, Meennahalli Palleda et al. https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Meennahalli Palleda, Girish
Gupta, Mohit
Bansal, Ankit
Batra, Vishal
Tyagi, Sanjay
Kunal, Shekhar
Long-Term Assessment of Thin-Strut BioMime Coronary Stent System in Real-World Population at Single-Center: A Retrospective Observational Study
title Long-Term Assessment of Thin-Strut BioMime Coronary Stent System in Real-World Population at Single-Center: A Retrospective Observational Study
title_full Long-Term Assessment of Thin-Strut BioMime Coronary Stent System in Real-World Population at Single-Center: A Retrospective Observational Study
title_fullStr Long-Term Assessment of Thin-Strut BioMime Coronary Stent System in Real-World Population at Single-Center: A Retrospective Observational Study
title_full_unstemmed Long-Term Assessment of Thin-Strut BioMime Coronary Stent System in Real-World Population at Single-Center: A Retrospective Observational Study
title_short Long-Term Assessment of Thin-Strut BioMime Coronary Stent System in Real-World Population at Single-Center: A Retrospective Observational Study
title_sort long-term assessment of thin-strut biomime coronary stent system in real-world population at single-center: a retrospective observational study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627375/
https://www.ncbi.nlm.nih.gov/pubmed/37936627
http://dx.doi.org/10.14740/cr1515
work_keys_str_mv AT meennahallipalledagirish longtermassessmentofthinstrutbiomimecoronarystentsysteminrealworldpopulationatsinglecenteraretrospectiveobservationalstudy
AT guptamohit longtermassessmentofthinstrutbiomimecoronarystentsysteminrealworldpopulationatsinglecenteraretrospectiveobservationalstudy
AT bansalankit longtermassessmentofthinstrutbiomimecoronarystentsysteminrealworldpopulationatsinglecenteraretrospectiveobservationalstudy
AT batravishal longtermassessmentofthinstrutbiomimecoronarystentsysteminrealworldpopulationatsinglecenteraretrospectiveobservationalstudy
AT tyagisanjay longtermassessmentofthinstrutbiomimecoronarystentsysteminrealworldpopulationatsinglecenteraretrospectiveobservationalstudy
AT kunalshekhar longtermassessmentofthinstrutbiomimecoronarystentsysteminrealworldpopulationatsinglecenteraretrospectiveobservationalstudy