Single-tube multiplex real-time PCR with EvaGreen and high-resolution melting analysis for diagnosis of α(0)-thalassemia--(SEA),--(THAI), and--(CR) type deletions

Regions with a high prevalence of α-thalassemia (α-thal) require simple, rapid, and accurate tests for carrier screening and prenatal diagnosis. Diagnosis of multiple deletions in a single tube is necessary to clearly identify individuals with α(0)-thalassemia in the routine setting, especially in a...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruengdit, Chedtapak, Punyamung, Manoo, Intasai, Nutjeera, Pornprasert, Sakorn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627449/
https://www.ncbi.nlm.nih.gov/pubmed/37930985
http://dx.doi.org/10.1371/journal.pone.0293838
_version_ 1785131529808117760
author Ruengdit, Chedtapak
Punyamung, Manoo
Intasai, Nutjeera
Pornprasert, Sakorn
author_facet Ruengdit, Chedtapak
Punyamung, Manoo
Intasai, Nutjeera
Pornprasert, Sakorn
author_sort Ruengdit, Chedtapak
collection PubMed
description Regions with a high prevalence of α-thalassemia (α-thal) require simple, rapid, and accurate tests for carrier screening and prenatal diagnosis. Diagnosis of multiple deletions in a single tube is necessary to clearly identify individuals with α(0)-thalassemia in the routine setting, especially in at-risk couples. Therefore, we aimed to develop a single-tube multiplex real-time PCR with EvaGreen and high-resolution melting (HRM) analysis for the identification of α(0)-thalassemia Southeast Asian (SEA), Thai and Chiang Rai (CR) type deletions. The results of the HRM analysis indicated that the amplified fragments from α(0)-thal--(CR),--(THAI),--(SEA), and the wild-type α-globin gene had specific peak heights at mean melting temperature (T(m)) values of 85.40°C, 86.50°C, 87.65°C, and 91.04°C, respectively. The frequencies of α(0)-thal--(SEA),--(THAI),--(CR) obtained from routine testing in 2,135 samples were 17.89%, 0.19% and 0.19%, respectively. This method would be useful for preventing Hb Bart’s hydrops fetalis. Detection of multiple deletions in a single run is cost-effective, highly accurate and timesaving. This technique could enable wider α-thalassemia diagnosis in high prevalence areas and served as an example for thalassemia routine setting.
format Online
Article
Text
id pubmed-10627449
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-106274492023-11-07 Single-tube multiplex real-time PCR with EvaGreen and high-resolution melting analysis for diagnosis of α(0)-thalassemia--(SEA),--(THAI), and--(CR) type deletions Ruengdit, Chedtapak Punyamung, Manoo Intasai, Nutjeera Pornprasert, Sakorn PLoS One Research Article Regions with a high prevalence of α-thalassemia (α-thal) require simple, rapid, and accurate tests for carrier screening and prenatal diagnosis. Diagnosis of multiple deletions in a single tube is necessary to clearly identify individuals with α(0)-thalassemia in the routine setting, especially in at-risk couples. Therefore, we aimed to develop a single-tube multiplex real-time PCR with EvaGreen and high-resolution melting (HRM) analysis for the identification of α(0)-thalassemia Southeast Asian (SEA), Thai and Chiang Rai (CR) type deletions. The results of the HRM analysis indicated that the amplified fragments from α(0)-thal--(CR),--(THAI),--(SEA), and the wild-type α-globin gene had specific peak heights at mean melting temperature (T(m)) values of 85.40°C, 86.50°C, 87.65°C, and 91.04°C, respectively. The frequencies of α(0)-thal--(SEA),--(THAI),--(CR) obtained from routine testing in 2,135 samples were 17.89%, 0.19% and 0.19%, respectively. This method would be useful for preventing Hb Bart’s hydrops fetalis. Detection of multiple deletions in a single run is cost-effective, highly accurate and timesaving. This technique could enable wider α-thalassemia diagnosis in high prevalence areas and served as an example for thalassemia routine setting. Public Library of Science 2023-11-06 /pmc/articles/PMC10627449/ /pubmed/37930985 http://dx.doi.org/10.1371/journal.pone.0293838 Text en © 2023 Ruengdit et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Ruengdit, Chedtapak
Punyamung, Manoo
Intasai, Nutjeera
Pornprasert, Sakorn
Single-tube multiplex real-time PCR with EvaGreen and high-resolution melting analysis for diagnosis of α(0)-thalassemia--(SEA),--(THAI), and--(CR) type deletions
title Single-tube multiplex real-time PCR with EvaGreen and high-resolution melting analysis for diagnosis of α(0)-thalassemia--(SEA),--(THAI), and--(CR) type deletions
title_full Single-tube multiplex real-time PCR with EvaGreen and high-resolution melting analysis for diagnosis of α(0)-thalassemia--(SEA),--(THAI), and--(CR) type deletions
title_fullStr Single-tube multiplex real-time PCR with EvaGreen and high-resolution melting analysis for diagnosis of α(0)-thalassemia--(SEA),--(THAI), and--(CR) type deletions
title_full_unstemmed Single-tube multiplex real-time PCR with EvaGreen and high-resolution melting analysis for diagnosis of α(0)-thalassemia--(SEA),--(THAI), and--(CR) type deletions
title_short Single-tube multiplex real-time PCR with EvaGreen and high-resolution melting analysis for diagnosis of α(0)-thalassemia--(SEA),--(THAI), and--(CR) type deletions
title_sort single-tube multiplex real-time pcr with evagreen and high-resolution melting analysis for diagnosis of α(0)-thalassemia--(sea),--(thai), and--(cr) type deletions
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627449/
https://www.ncbi.nlm.nih.gov/pubmed/37930985
http://dx.doi.org/10.1371/journal.pone.0293838
work_keys_str_mv AT ruengditchedtapak singletubemultiplexrealtimepcrwithevagreenandhighresolutionmeltinganalysisfordiagnosisofa0thalassemiaseathaiandcrtypedeletions
AT punyamungmanoo singletubemultiplexrealtimepcrwithevagreenandhighresolutionmeltinganalysisfordiagnosisofa0thalassemiaseathaiandcrtypedeletions
AT intasainutjeera singletubemultiplexrealtimepcrwithevagreenandhighresolutionmeltinganalysisfordiagnosisofa0thalassemiaseathaiandcrtypedeletions
AT pornprasertsakorn singletubemultiplexrealtimepcrwithevagreenandhighresolutionmeltinganalysisfordiagnosisofa0thalassemiaseathaiandcrtypedeletions