Cargando…

Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique

Arthroscopic rotator cuff repair is one of the most painful surgical procedures; patients complain of pain especially during the first 48 hours postoperatively. Pain management is an essential goal to reduce the demand for analgesic agents and patient discomfort. Various methods have been introduced...

Descripción completa

Detalles Bibliográficos
Autores principales: Ali, Maslah Idiris, Tang, Yiyong, Hou, Jingyi, Long, Yi, Zhou, Chuanhai, Wang, Zhiling, Yang, Rui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627854/
https://www.ncbi.nlm.nih.gov/pubmed/37942096
http://dx.doi.org/10.1016/j.eats.2023.05.019
_version_ 1785131620114628608
author Ali, Maslah Idiris
Tang, Yiyong
Hou, Jingyi
Long, Yi
Zhou, Chuanhai
Wang, Zhiling
Yang, Rui
author_facet Ali, Maslah Idiris
Tang, Yiyong
Hou, Jingyi
Long, Yi
Zhou, Chuanhai
Wang, Zhiling
Yang, Rui
author_sort Ali, Maslah Idiris
collection PubMed
description Arthroscopic rotator cuff repair is one of the most painful surgical procedures; patients complain of pain especially during the first 48 hours postoperatively. Pain management is an essential goal to reduce the demand for analgesic agents and patient discomfort. Various methods have been introduced for arthroscopic rotator cuff repair, including continuous arthroscopy-guided suprascapular nerve blocks (SSNB) and interscalene nerve blocks. However, the aforementioned procedures have shown disadvantages such as catheter mobilization, which may cause injury to the artery, a weak analgesic effect, and Horner syndrome, as well as phrenic nerve paralysis. A modification of the continuous arthroscopy-guided SSNB has been introduced at our hospital: the modified continuous arthroscopy-guided SSNB technique. The aim of this technique is to immobilize the catheter to reduce the chance of injury and minimize postsurgical analgesic needs and patient discomfort.
format Online
Article
Text
id pubmed-10627854
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-106278542023-11-08 Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique Ali, Maslah Idiris Tang, Yiyong Hou, Jingyi Long, Yi Zhou, Chuanhai Wang, Zhiling Yang, Rui Arthrosc Tech Technical Note Arthroscopic rotator cuff repair is one of the most painful surgical procedures; patients complain of pain especially during the first 48 hours postoperatively. Pain management is an essential goal to reduce the demand for analgesic agents and patient discomfort. Various methods have been introduced for arthroscopic rotator cuff repair, including continuous arthroscopy-guided suprascapular nerve blocks (SSNB) and interscalene nerve blocks. However, the aforementioned procedures have shown disadvantages such as catheter mobilization, which may cause injury to the artery, a weak analgesic effect, and Horner syndrome, as well as phrenic nerve paralysis. A modification of the continuous arthroscopy-guided SSNB has been introduced at our hospital: the modified continuous arthroscopy-guided SSNB technique. The aim of this technique is to immobilize the catheter to reduce the chance of injury and minimize postsurgical analgesic needs and patient discomfort. Elsevier 2023-09-11 /pmc/articles/PMC10627854/ /pubmed/37942096 http://dx.doi.org/10.1016/j.eats.2023.05.019 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Technical Note
Ali, Maslah Idiris
Tang, Yiyong
Hou, Jingyi
Long, Yi
Zhou, Chuanhai
Wang, Zhiling
Yang, Rui
Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique
title Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique
title_full Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique
title_fullStr Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique
title_full_unstemmed Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique
title_short Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique
title_sort modified continuous arthroscopy-guided suprascapular nerve block for postoperative pain control following rotator cuff repair: surgical technique
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627854/
https://www.ncbi.nlm.nih.gov/pubmed/37942096
http://dx.doi.org/10.1016/j.eats.2023.05.019
work_keys_str_mv AT alimaslahidiris modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique
AT tangyiyong modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique
AT houjingyi modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique
AT longyi modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique
AT zhouchuanhai modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique
AT wangzhiling modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique
AT yangrui modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique