Cargando…
Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique
Arthroscopic rotator cuff repair is one of the most painful surgical procedures; patients complain of pain especially during the first 48 hours postoperatively. Pain management is an essential goal to reduce the demand for analgesic agents and patient discomfort. Various methods have been introduced...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627854/ https://www.ncbi.nlm.nih.gov/pubmed/37942096 http://dx.doi.org/10.1016/j.eats.2023.05.019 |
_version_ | 1785131620114628608 |
---|---|
author | Ali, Maslah Idiris Tang, Yiyong Hou, Jingyi Long, Yi Zhou, Chuanhai Wang, Zhiling Yang, Rui |
author_facet | Ali, Maslah Idiris Tang, Yiyong Hou, Jingyi Long, Yi Zhou, Chuanhai Wang, Zhiling Yang, Rui |
author_sort | Ali, Maslah Idiris |
collection | PubMed |
description | Arthroscopic rotator cuff repair is one of the most painful surgical procedures; patients complain of pain especially during the first 48 hours postoperatively. Pain management is an essential goal to reduce the demand for analgesic agents and patient discomfort. Various methods have been introduced for arthroscopic rotator cuff repair, including continuous arthroscopy-guided suprascapular nerve blocks (SSNB) and interscalene nerve blocks. However, the aforementioned procedures have shown disadvantages such as catheter mobilization, which may cause injury to the artery, a weak analgesic effect, and Horner syndrome, as well as phrenic nerve paralysis. A modification of the continuous arthroscopy-guided SSNB has been introduced at our hospital: the modified continuous arthroscopy-guided SSNB technique. The aim of this technique is to immobilize the catheter to reduce the chance of injury and minimize postsurgical analgesic needs and patient discomfort. |
format | Online Article Text |
id | pubmed-10627854 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-106278542023-11-08 Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique Ali, Maslah Idiris Tang, Yiyong Hou, Jingyi Long, Yi Zhou, Chuanhai Wang, Zhiling Yang, Rui Arthrosc Tech Technical Note Arthroscopic rotator cuff repair is one of the most painful surgical procedures; patients complain of pain especially during the first 48 hours postoperatively. Pain management is an essential goal to reduce the demand for analgesic agents and patient discomfort. Various methods have been introduced for arthroscopic rotator cuff repair, including continuous arthroscopy-guided suprascapular nerve blocks (SSNB) and interscalene nerve blocks. However, the aforementioned procedures have shown disadvantages such as catheter mobilization, which may cause injury to the artery, a weak analgesic effect, and Horner syndrome, as well as phrenic nerve paralysis. A modification of the continuous arthroscopy-guided SSNB has been introduced at our hospital: the modified continuous arthroscopy-guided SSNB technique. The aim of this technique is to immobilize the catheter to reduce the chance of injury and minimize postsurgical analgesic needs and patient discomfort. Elsevier 2023-09-11 /pmc/articles/PMC10627854/ /pubmed/37942096 http://dx.doi.org/10.1016/j.eats.2023.05.019 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Technical Note Ali, Maslah Idiris Tang, Yiyong Hou, Jingyi Long, Yi Zhou, Chuanhai Wang, Zhiling Yang, Rui Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique |
title | Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique |
title_full | Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique |
title_fullStr | Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique |
title_full_unstemmed | Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique |
title_short | Modified Continuous Arthroscopy-Guided Suprascapular Nerve Block for Postoperative Pain Control Following Rotator Cuff Repair: Surgical Technique |
title_sort | modified continuous arthroscopy-guided suprascapular nerve block for postoperative pain control following rotator cuff repair: surgical technique |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627854/ https://www.ncbi.nlm.nih.gov/pubmed/37942096 http://dx.doi.org/10.1016/j.eats.2023.05.019 |
work_keys_str_mv | AT alimaslahidiris modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique AT tangyiyong modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique AT houjingyi modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique AT longyi modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique AT zhouchuanhai modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique AT wangzhiling modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique AT yangrui modifiedcontinuousarthroscopyguidedsuprascapularnerveblockforpostoperativepaincontrolfollowingrotatorcuffrepairsurgicaltechnique |