Cargando…
Risk of anastomotic leakage with two-row versus three-row manual circular staplers in colorectal anastomosis: a U.S. cohort study
PURPOSES: To compare the risk of anastomotic leak (AL) between Ethicon manual circular staplers (two-row) versus Medtronic EEA(™) circular stapler with Tri-Staple(™) technology (three-row) and between Medtronic EEA(™) circular stapler with DST(™) Series technology (two-row) versus Tri-Staple(™) tech...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627892/ https://www.ncbi.nlm.nih.gov/pubmed/37932486 http://dx.doi.org/10.1007/s00384-023-04552-0 |
_version_ | 1785131628564054016 |
---|---|
author | Wang, Tongtong Sadowsky, Mordechai Blakney, Rebekah Coplan, Paul Petraiuolo, William Soberman, Mark Tomaszewski, Joerg Rene, Lexi Wood, Jennifer |
author_facet | Wang, Tongtong Sadowsky, Mordechai Blakney, Rebekah Coplan, Paul Petraiuolo, William Soberman, Mark Tomaszewski, Joerg Rene, Lexi Wood, Jennifer |
author_sort | Wang, Tongtong |
collection | PubMed |
description | PURPOSES: To compare the risk of anastomotic leak (AL) between Ethicon manual circular staplers (two-row) versus Medtronic EEA(™) circular stapler with Tri-Staple(™) technology (three-row) and between Medtronic EEA(™) circular stapler with DST(™) Series technology (two-row) versus Tri-Staple(™) technology. METHODS: A retrospective cohort study was conducted in adult patients who underwent a left-sided colorectal surgery 2019–2022 in U.S. Premier Healthcare Database to assess the risk of AL within 30 days post-index procedure. The study devices were Ethicon manual circular staplers, Medtronic EEA(™) circular stapler with DST(™) technology, and Medtronic EEA(™) circular stapler with Tri-Staple(™) technology. RESULTS: Across 447 hospitals, the cumulative incidences (95% confidence intervals [CI]) of AL within 30 days post-index procedure were 7.78% (6.91–8.74%) among 8337 patients in the Ethicon manual circular stapler cohort, 7.54% (6.87–8.27%) among 7928 patients in the Medtronic EEA(™) circular stapler with DST(™) technology cohort, and 8.19% (6.57–10.07%) among 1306 patients in the Medtronic EEA(™) circular stapler with Tri-Staple(™) technology cohort. Comparative analyses revealed no difference comparing Ethicon manual circular staplers with Medtronic EEA(™) circular staplers with Tri-Staple(™) technology (risk ratio [RR], 0.72; 95% CI, 0.52–1.01) or comparing Medtronic EEA(™) circular staplers with DST(™) technology to Tri-Staple(™) technology (RR, 0.75; 95% CI, 0.53–1.06). CONCLUSION: In this analysis of a large cohort of patients undergoing a left-sided colorectal surgery from a U.S. hospital database, the risk of AL observed with manual two-row circular staplers was similar to that seen with three-row devices. This study affirms the safety of manual two-row circular staplers in colorectal anastomosis. |
format | Online Article Text |
id | pubmed-10627892 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-106278922023-11-08 Risk of anastomotic leakage with two-row versus three-row manual circular staplers in colorectal anastomosis: a U.S. cohort study Wang, Tongtong Sadowsky, Mordechai Blakney, Rebekah Coplan, Paul Petraiuolo, William Soberman, Mark Tomaszewski, Joerg Rene, Lexi Wood, Jennifer Int J Colorectal Dis Research PURPOSES: To compare the risk of anastomotic leak (AL) between Ethicon manual circular staplers (two-row) versus Medtronic EEA(™) circular stapler with Tri-Staple(™) technology (three-row) and between Medtronic EEA(™) circular stapler with DST(™) Series technology (two-row) versus Tri-Staple(™) technology. METHODS: A retrospective cohort study was conducted in adult patients who underwent a left-sided colorectal surgery 2019–2022 in U.S. Premier Healthcare Database to assess the risk of AL within 30 days post-index procedure. The study devices were Ethicon manual circular staplers, Medtronic EEA(™) circular stapler with DST(™) technology, and Medtronic EEA(™) circular stapler with Tri-Staple(™) technology. RESULTS: Across 447 hospitals, the cumulative incidences (95% confidence intervals [CI]) of AL within 30 days post-index procedure were 7.78% (6.91–8.74%) among 8337 patients in the Ethicon manual circular stapler cohort, 7.54% (6.87–8.27%) among 7928 patients in the Medtronic EEA(™) circular stapler with DST(™) technology cohort, and 8.19% (6.57–10.07%) among 1306 patients in the Medtronic EEA(™) circular stapler with Tri-Staple(™) technology cohort. Comparative analyses revealed no difference comparing Ethicon manual circular staplers with Medtronic EEA(™) circular staplers with Tri-Staple(™) technology (risk ratio [RR], 0.72; 95% CI, 0.52–1.01) or comparing Medtronic EEA(™) circular staplers with DST(™) technology to Tri-Staple(™) technology (RR, 0.75; 95% CI, 0.53–1.06). CONCLUSION: In this analysis of a large cohort of patients undergoing a left-sided colorectal surgery from a U.S. hospital database, the risk of AL observed with manual two-row circular staplers was similar to that seen with three-row devices. This study affirms the safety of manual two-row circular staplers in colorectal anastomosis. Springer Berlin Heidelberg 2023-11-07 2023 /pmc/articles/PMC10627892/ /pubmed/37932486 http://dx.doi.org/10.1007/s00384-023-04552-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Wang, Tongtong Sadowsky, Mordechai Blakney, Rebekah Coplan, Paul Petraiuolo, William Soberman, Mark Tomaszewski, Joerg Rene, Lexi Wood, Jennifer Risk of anastomotic leakage with two-row versus three-row manual circular staplers in colorectal anastomosis: a U.S. cohort study |
title | Risk of anastomotic leakage with two-row versus three-row manual circular staplers in colorectal anastomosis: a U.S. cohort study |
title_full | Risk of anastomotic leakage with two-row versus three-row manual circular staplers in colorectal anastomosis: a U.S. cohort study |
title_fullStr | Risk of anastomotic leakage with two-row versus three-row manual circular staplers in colorectal anastomosis: a U.S. cohort study |
title_full_unstemmed | Risk of anastomotic leakage with two-row versus three-row manual circular staplers in colorectal anastomosis: a U.S. cohort study |
title_short | Risk of anastomotic leakage with two-row versus three-row manual circular staplers in colorectal anastomosis: a U.S. cohort study |
title_sort | risk of anastomotic leakage with two-row versus three-row manual circular staplers in colorectal anastomosis: a u.s. cohort study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627892/ https://www.ncbi.nlm.nih.gov/pubmed/37932486 http://dx.doi.org/10.1007/s00384-023-04552-0 |
work_keys_str_mv | AT wangtongtong riskofanastomoticleakagewithtworowversusthreerowmanualcircularstaplersincolorectalanastomosisauscohortstudy AT sadowskymordechai riskofanastomoticleakagewithtworowversusthreerowmanualcircularstaplersincolorectalanastomosisauscohortstudy AT blakneyrebekah riskofanastomoticleakagewithtworowversusthreerowmanualcircularstaplersincolorectalanastomosisauscohortstudy AT coplanpaul riskofanastomoticleakagewithtworowversusthreerowmanualcircularstaplersincolorectalanastomosisauscohortstudy AT petraiuolowilliam riskofanastomoticleakagewithtworowversusthreerowmanualcircularstaplersincolorectalanastomosisauscohortstudy AT sobermanmark riskofanastomoticleakagewithtworowversusthreerowmanualcircularstaplersincolorectalanastomosisauscohortstudy AT tomaszewskijoerg riskofanastomoticleakagewithtworowversusthreerowmanualcircularstaplersincolorectalanastomosisauscohortstudy AT renelexi riskofanastomoticleakagewithtworowversusthreerowmanualcircularstaplersincolorectalanastomosisauscohortstudy AT woodjennifer riskofanastomoticleakagewithtworowversusthreerowmanualcircularstaplersincolorectalanastomosisauscohortstudy |