Cargando…
Multi-modality imaging of high-intensity plaques on non-contrast T1-weighted magnetic resonance imaging: a case report
BACKGROUND: Non-contrast T1-weighted imaging (T1WI) with cardiac magnetic resonance enables to evaluate the intensity of coronary plaque. Plaque-to-myocardial signal intensity ratio (PMR) has been shown to associate with an elevated risk of future coronary events. Of note, PMR >1.4 is a best cut-...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10628425/ https://www.ncbi.nlm.nih.gov/pubmed/37941843 http://dx.doi.org/10.21037/cdt-23-125 |
Sumario: | BACKGROUND: Non-contrast T1-weighted imaging (T1WI) with cardiac magnetic resonance enables to evaluate the intensity of coronary plaque. Plaque-to-myocardial signal intensity ratio (PMR) has been shown to associate with an elevated risk of future coronary events. Of note, PMR >1.4 is a best cut-off value to identify high-risk plaque causing future coronary events. One recent study has reported intraluminal thrombus as a contributor to PMR. However, whether plaque material itself is associated with PMR has not been fully characterized yet. We present three cases with coronary artery stenosis evaluated by non-contrast T1WI-magnetic resonance imaging, optical coherence tomography (OCT) and near-infrared spectroscopy (NIRS)-intravascular ultrasound (IVUS) imaging. CASE DESCRIPTION: Case 1 exhibited one lesion with high PMR (2.79) at the proximal segment of left anterior descending (LAD) artery. OCT imaging did not identify any obvious intra-luminal thrombus but the presence of lipid-rich plaque harboring cholesterol crystal at the corresponding lesion. In addition, an elevated maximum 4-mm lipid-core burden index (maxLCBI(4mm)) (=873) was observed at this lesion by NIRS/IVUS imaging. In case 2, PMR of coronary stenosis at the middle segment of LAD artery was 1.88. This lesion harboured lipidic materials without any thrombus on OCT imaging. NIRS-derived maxLCBI(4mm) was 725. Case 3 had a severe stenosis at the middle segment of LAD artery. This lesion exhibited a low PMR (0.90). On OCT and NIRS/IVUS imaging, this lesion was characterized as the presence of small lipid arc with a low maxLCBI(4mm) (=386). CONCLUSIONS: These cases showed the possible relationship of T1WI-derived PMR with the degree of lipidic plaque components. |
---|