Cargando…

Diagnostic accuracy of superb microvascular imaging for detecting intraplaque neovascularization: a systematic review and meta-analysis

BACKGROUND: Atherosclerotic plaques can cause carotid artery stenosis, and “vulnerable plaques” can even lead to ischemic stroke. The objective of this study was to assess the accuracy of superb microvascular imaging (SMI) for the detection of carotid intraplaque neovascularization (IPN) in patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Lina, Han, Yubo, Che, Yanling, Zhang, Xuesong, Luo, Min, Li, Jinzhu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10628429/
https://www.ncbi.nlm.nih.gov/pubmed/37941846
http://dx.doi.org/10.21037/cdt-23-202
_version_ 1785131756470403072
author Zhao, Lina
Han, Yubo
Che, Yanling
Zhang, Xuesong
Luo, Min
Li, Jinzhu
author_facet Zhao, Lina
Han, Yubo
Che, Yanling
Zhang, Xuesong
Luo, Min
Li, Jinzhu
author_sort Zhao, Lina
collection PubMed
description BACKGROUND: Atherosclerotic plaques can cause carotid artery stenosis, and “vulnerable plaques” can even lead to ischemic stroke. The objective of this study was to assess the accuracy of superb microvascular imaging (SMI) for the detection of carotid intraplaque neovascularization (IPN) in patients with atherosclerotic plaques. METHODS: We searched the Cochrane Library, Embase, Medline, and Wanfang databases until January 17, 2023. We included original studies with information on diagnostic accuracy of SMI for the evaluation of carotid IPN. The primary outcome was the accuracy of SMI for detecting carotid IPN. A meta-analysis was performed to estimate the accuracy of each parameter. We used the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) to assess the risk of bias for each included article. Meta-regression was performed to determine items that may have contributed to heterogeneity in the sensitivity or specificity of the test. RESULTS: This meta-analysis included 20 studies with 1,589 carotid plaques in 1,225 patients. The analysis showed a sensitivity and specificity of SMI for detecting IPN of 93% [95% confidence interval (CI): 87–96%] and 80% (95% CI: 71–87%), respectively. The risk of bias across the QUADAS-2 domains was low. Only the proportion of dyslipidemia influenced the estimates of sensitivity and specificity. CONCLUSIONS: This review suggests that SMI has a good diagnostic performance for detecting carotid IPN. The very high sensitivity with excellent post-test probability indicated that SMI can be recommended to screen for carotid IPN among patients with carotid plaques.
format Online
Article
Text
id pubmed-10628429
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-106284292023-11-08 Diagnostic accuracy of superb microvascular imaging for detecting intraplaque neovascularization: a systematic review and meta-analysis Zhao, Lina Han, Yubo Che, Yanling Zhang, Xuesong Luo, Min Li, Jinzhu Cardiovasc Diagn Ther Original Article BACKGROUND: Atherosclerotic plaques can cause carotid artery stenosis, and “vulnerable plaques” can even lead to ischemic stroke. The objective of this study was to assess the accuracy of superb microvascular imaging (SMI) for the detection of carotid intraplaque neovascularization (IPN) in patients with atherosclerotic plaques. METHODS: We searched the Cochrane Library, Embase, Medline, and Wanfang databases until January 17, 2023. We included original studies with information on diagnostic accuracy of SMI for the evaluation of carotid IPN. The primary outcome was the accuracy of SMI for detecting carotid IPN. A meta-analysis was performed to estimate the accuracy of each parameter. We used the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) to assess the risk of bias for each included article. Meta-regression was performed to determine items that may have contributed to heterogeneity in the sensitivity or specificity of the test. RESULTS: This meta-analysis included 20 studies with 1,589 carotid plaques in 1,225 patients. The analysis showed a sensitivity and specificity of SMI for detecting IPN of 93% [95% confidence interval (CI): 87–96%] and 80% (95% CI: 71–87%), respectively. The risk of bias across the QUADAS-2 domains was low. Only the proportion of dyslipidemia influenced the estimates of sensitivity and specificity. CONCLUSIONS: This review suggests that SMI has a good diagnostic performance for detecting carotid IPN. The very high sensitivity with excellent post-test probability indicated that SMI can be recommended to screen for carotid IPN among patients with carotid plaques. AME Publishing Company 2023-10-24 2023-10-31 /pmc/articles/PMC10628429/ /pubmed/37941846 http://dx.doi.org/10.21037/cdt-23-202 Text en 2023 Cardiovascular Diagnosis and Therapy. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Zhao, Lina
Han, Yubo
Che, Yanling
Zhang, Xuesong
Luo, Min
Li, Jinzhu
Diagnostic accuracy of superb microvascular imaging for detecting intraplaque neovascularization: a systematic review and meta-analysis
title Diagnostic accuracy of superb microvascular imaging for detecting intraplaque neovascularization: a systematic review and meta-analysis
title_full Diagnostic accuracy of superb microvascular imaging for detecting intraplaque neovascularization: a systematic review and meta-analysis
title_fullStr Diagnostic accuracy of superb microvascular imaging for detecting intraplaque neovascularization: a systematic review and meta-analysis
title_full_unstemmed Diagnostic accuracy of superb microvascular imaging for detecting intraplaque neovascularization: a systematic review and meta-analysis
title_short Diagnostic accuracy of superb microvascular imaging for detecting intraplaque neovascularization: a systematic review and meta-analysis
title_sort diagnostic accuracy of superb microvascular imaging for detecting intraplaque neovascularization: a systematic review and meta-analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10628429/
https://www.ncbi.nlm.nih.gov/pubmed/37941846
http://dx.doi.org/10.21037/cdt-23-202
work_keys_str_mv AT zhaolina diagnosticaccuracyofsuperbmicrovascularimagingfordetectingintraplaqueneovascularizationasystematicreviewandmetaanalysis
AT hanyubo diagnosticaccuracyofsuperbmicrovascularimagingfordetectingintraplaqueneovascularizationasystematicreviewandmetaanalysis
AT cheyanling diagnosticaccuracyofsuperbmicrovascularimagingfordetectingintraplaqueneovascularizationasystematicreviewandmetaanalysis
AT zhangxuesong diagnosticaccuracyofsuperbmicrovascularimagingfordetectingintraplaqueneovascularizationasystematicreviewandmetaanalysis
AT luomin diagnosticaccuracyofsuperbmicrovascularimagingfordetectingintraplaqueneovascularizationasystematicreviewandmetaanalysis
AT lijinzhu diagnosticaccuracyofsuperbmicrovascularimagingfordetectingintraplaqueneovascularizationasystematicreviewandmetaanalysis