Cargando…

Evaluation of three-dimensional dual-energy CT cholangiopancreatography image quality in patients with pancreatobiliary dilatation: Comparison with conventional single-energy CT

OBJECTIVE: This study aimed to evaluate three-dimensional (3D) negative-contrast CT cholangiopancreatography (nCTCP) image quality using dual-energy CT (DECT) with iterative reconstruction (IR) technique in patients with pancreatobiliary dilatation compared with single-energy CT (SECT). METHODS: Of...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Bin, Ni, JianMing, Chen, FangMing, Lu, FengQi, Zhang, Lei, Wu, WenJuan, Zhang, ZhuiYang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10628547/
https://www.ncbi.nlm.nih.gov/pubmed/37942123
http://dx.doi.org/10.1016/j.ejro.2023.100537
_version_ 1785131783449214976
author Li, Bin
Ni, JianMing
Chen, FangMing
Lu, FengQi
Zhang, Lei
Wu, WenJuan
Zhang, ZhuiYang
author_facet Li, Bin
Ni, JianMing
Chen, FangMing
Lu, FengQi
Zhang, Lei
Wu, WenJuan
Zhang, ZhuiYang
author_sort Li, Bin
collection PubMed
description OBJECTIVE: This study aimed to evaluate three-dimensional (3D) negative-contrast CT cholangiopancreatography (nCTCP) image quality using dual-energy CT (DECT) with iterative reconstruction (IR) technique in patients with pancreatobiliary dilatation compared with single-energy CT (SECT). METHODS: Of the patients, 67 and 56 underwent conventional SECT (SECT set) and DECT with IR technique (DECT set), respectively. All patients were retrospectively analyzed during the portal phase to compare objective image quality and other data including patient demographics, hepatic and pancreatic parenchymal enhancement, noise, and attenuation difference (AD) between dilated ducts and enhanced hepatic parenchyma, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and CT volume dose index (CTDI(vol)). Two radiologists used the five-point Likert scale to evaluate the subjective image quality of 3D nCTCP regarding image noise, sharpness of dilated ducts, and overall image quality. Statistical analyses used the Mann–Whitney U test. RESULTS: No significant difference in patient demographics in either CT set was showed during objective evaluation (p > 0.05). However, higher hepatic and pancreatic parenchymal enhancement, AD, SNR, and CNR and lower hepatic and pancreatic noise (p < 0.005) as well as CTDI(vol) (p = 0.005) on DECT than on SECT were observed. Higher mean grades on DECT than on SECT were showed for image noise (4.65 vs 3.92), sharpness of dilated ducts (4.52 vs 3.94), and overall image quality (4.45 vs 3.91; p < 0.001), respectively during subjective evaluation. CONCLUSION: A higher overall image quality and lower radiation dose on 3D nCTCP can be obtained by DECT with IR technique than with conventional SECT in patients with pancreatobiliary dilatation.
format Online
Article
Text
id pubmed-10628547
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-106285472023-11-08 Evaluation of three-dimensional dual-energy CT cholangiopancreatography image quality in patients with pancreatobiliary dilatation: Comparison with conventional single-energy CT Li, Bin Ni, JianMing Chen, FangMing Lu, FengQi Zhang, Lei Wu, WenJuan Zhang, ZhuiYang Eur J Radiol Open Article OBJECTIVE: This study aimed to evaluate three-dimensional (3D) negative-contrast CT cholangiopancreatography (nCTCP) image quality using dual-energy CT (DECT) with iterative reconstruction (IR) technique in patients with pancreatobiliary dilatation compared with single-energy CT (SECT). METHODS: Of the patients, 67 and 56 underwent conventional SECT (SECT set) and DECT with IR technique (DECT set), respectively. All patients were retrospectively analyzed during the portal phase to compare objective image quality and other data including patient demographics, hepatic and pancreatic parenchymal enhancement, noise, and attenuation difference (AD) between dilated ducts and enhanced hepatic parenchyma, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and CT volume dose index (CTDI(vol)). Two radiologists used the five-point Likert scale to evaluate the subjective image quality of 3D nCTCP regarding image noise, sharpness of dilated ducts, and overall image quality. Statistical analyses used the Mann–Whitney U test. RESULTS: No significant difference in patient demographics in either CT set was showed during objective evaluation (p > 0.05). However, higher hepatic and pancreatic parenchymal enhancement, AD, SNR, and CNR and lower hepatic and pancreatic noise (p < 0.005) as well as CTDI(vol) (p = 0.005) on DECT than on SECT were observed. Higher mean grades on DECT than on SECT were showed for image noise (4.65 vs 3.92), sharpness of dilated ducts (4.52 vs 3.94), and overall image quality (4.45 vs 3.91; p < 0.001), respectively during subjective evaluation. CONCLUSION: A higher overall image quality and lower radiation dose on 3D nCTCP can be obtained by DECT with IR technique than with conventional SECT in patients with pancreatobiliary dilatation. Elsevier 2023-10-27 /pmc/articles/PMC10628547/ /pubmed/37942123 http://dx.doi.org/10.1016/j.ejro.2023.100537 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Li, Bin
Ni, JianMing
Chen, FangMing
Lu, FengQi
Zhang, Lei
Wu, WenJuan
Zhang, ZhuiYang
Evaluation of three-dimensional dual-energy CT cholangiopancreatography image quality in patients with pancreatobiliary dilatation: Comparison with conventional single-energy CT
title Evaluation of three-dimensional dual-energy CT cholangiopancreatography image quality in patients with pancreatobiliary dilatation: Comparison with conventional single-energy CT
title_full Evaluation of three-dimensional dual-energy CT cholangiopancreatography image quality in patients with pancreatobiliary dilatation: Comparison with conventional single-energy CT
title_fullStr Evaluation of three-dimensional dual-energy CT cholangiopancreatography image quality in patients with pancreatobiliary dilatation: Comparison with conventional single-energy CT
title_full_unstemmed Evaluation of three-dimensional dual-energy CT cholangiopancreatography image quality in patients with pancreatobiliary dilatation: Comparison with conventional single-energy CT
title_short Evaluation of three-dimensional dual-energy CT cholangiopancreatography image quality in patients with pancreatobiliary dilatation: Comparison with conventional single-energy CT
title_sort evaluation of three-dimensional dual-energy ct cholangiopancreatography image quality in patients with pancreatobiliary dilatation: comparison with conventional single-energy ct
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10628547/
https://www.ncbi.nlm.nih.gov/pubmed/37942123
http://dx.doi.org/10.1016/j.ejro.2023.100537
work_keys_str_mv AT libin evaluationofthreedimensionaldualenergyctcholangiopancreatographyimagequalityinpatientswithpancreatobiliarydilatationcomparisonwithconventionalsingleenergyct
AT nijianming evaluationofthreedimensionaldualenergyctcholangiopancreatographyimagequalityinpatientswithpancreatobiliarydilatationcomparisonwithconventionalsingleenergyct
AT chenfangming evaluationofthreedimensionaldualenergyctcholangiopancreatographyimagequalityinpatientswithpancreatobiliarydilatationcomparisonwithconventionalsingleenergyct
AT lufengqi evaluationofthreedimensionaldualenergyctcholangiopancreatographyimagequalityinpatientswithpancreatobiliarydilatationcomparisonwithconventionalsingleenergyct
AT zhanglei evaluationofthreedimensionaldualenergyctcholangiopancreatographyimagequalityinpatientswithpancreatobiliarydilatationcomparisonwithconventionalsingleenergyct
AT wuwenjuan evaluationofthreedimensionaldualenergyctcholangiopancreatographyimagequalityinpatientswithpancreatobiliarydilatationcomparisonwithconventionalsingleenergyct
AT zhangzhuiyang evaluationofthreedimensionaldualenergyctcholangiopancreatographyimagequalityinpatientswithpancreatobiliarydilatationcomparisonwithconventionalsingleenergyct