Cargando…

Dynamic changes of left atrial substrate over time following pulmonary vein isolation: the Progress-AF study

AIMS: Little is known about dynamic changes of the left atrial (LA) substrate over time in patients with atrial fibrillation (AF). This study aims to evaluate substrate changes following pulmonary vein isolation (PVI). METHODS AND RESULTS: In our prospective observational study, consecutive patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Marcon, Lorenzo, Bergonti, Marco, Spera, Francesco, Saenen, Johan, Huybrechts, Wim, Miljoen, Hielko, Van Leuven, Olivier, Vandaele, Lien, Wittock, Anouk, Heidbuchel, Hein, Sarkozy, Andrea
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10629715/
https://www.ncbi.nlm.nih.gov/pubmed/37787610
http://dx.doi.org/10.1093/europace/euad299
Descripción
Sumario:AIMS: Little is known about dynamic changes of the left atrial (LA) substrate over time in patients with atrial fibrillation (AF). This study aims to evaluate substrate changes following pulmonary vein isolation (PVI). METHODS AND RESULTS: In our prospective observational study, consecutive patients undergoing first PVI-only and redo ablation were included. High-density maps of the two procedures were compared. Progression or regression was diagnosed if a significant concordant decrease or increase in bipolar voltages in ≥2 segments was observed, respectively. In 28 patients (61.2 ± 9.5 years, 39% female, 53.5% persistent AF), 111.013 voltage points from 56 high-density LA maps (1.982 points/patient) were analysed. Comparing the high-density maps of the first and second procedures, in the progression group (17 patients, 61%), there was a decrease in global (−35%, P < 0.001) and all regional voltages. In the regression group (11 patients, 39%), there was an increase in global (+43%, P < 0.001) and regional voltages. Comparing the progression with the regression group, the area of low-voltage zone (LVZ) increased (+3.5 vs. −4.5 cm(2), P < 0.001) and LA activation time prolonged (+8.0 vs. −9.1 ms, P = 0.005). Baseline clinical parameters did not predict progression or regression. In patients with substrate progression, pulmonary veins (PVs) were more frequently isolated (P = 0.02) and the AF pattern at recurrence was more frequently persistent (P = 0.005). CONCLUSION: Our study describes bidirectional dynamic properties of the LA substrate with concordant either progressive or regressive changes. Regression occurs with reduced AF burden after the first procedure, while progression is associated with persistent AF recurrence despite durable PV isolation. The dynamic nature of LA substrate poses questions about LVZ-based ablation strategies.