Cargando…

Optimal interlesion distance for 90 and 50 watt radiofrequency applications with low ablation index values: experimental findings in a chronic ovine model

AIMS: The optimal interlesion distance (ILD) for 90 and 50 W radiofrequency applications with low ablation index (AI) values in the atria has not been established. Excessive ILDs can predispose to interlesion gaps, whereas restrictive ILDs can predispose to procedural complications. The present stud...

Descripción completa

Detalles Bibliográficos
Autores principales: Bortone, Agustín Alfonso, Ramirez, F Daniel, Constantin, Marion, Bortone, Clara, Hébert, Caroline, Constantin, Justine, Bialas, Patric, Limite, Luca Rosario
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10629717/
https://www.ncbi.nlm.nih.gov/pubmed/37851513
http://dx.doi.org/10.1093/europace/euad310
_version_ 1785132015762276352
author Bortone, Agustín Alfonso
Ramirez, F Daniel
Constantin, Marion
Bortone, Clara
Hébert, Caroline
Constantin, Justine
Bialas, Patric
Limite, Luca Rosario
author_facet Bortone, Agustín Alfonso
Ramirez, F Daniel
Constantin, Marion
Bortone, Clara
Hébert, Caroline
Constantin, Justine
Bialas, Patric
Limite, Luca Rosario
author_sort Bortone, Agustín Alfonso
collection PubMed
description AIMS: The optimal interlesion distance (ILD) for 90 and 50 W radiofrequency applications with low ablation index (AI) values in the atria has not been established. Excessive ILDs can predispose to interlesion gaps, whereas restrictive ILDs can predispose to procedural complications. The present study sought, therefore, to experimentally determine the optimal ILD for 90 W–4 s and 50 W applications with low AI values to optimize catheter ablation outcomes in humans. METHODS AND RESULTS: Posterior intercaval lines were created in eight adult sheep using CARTO and the QDOT-MICRO catheter in a temperature-controlled mode. In four animals, the lines were created with 50 W applications, a target AI value ≥350, and ILDs of 6, 5, 4, and 3 mm, respectively. In the other four animals, the lines were created with 90 W–4 s applications and ILDs of 6, 5, 4, and 3 mm, respectively. Activation maps were created immediately after ablation and at 21 days to assess linear block prior to gross and histological analyses. All eight lines appeared transmural and continuous on histology. However, for 50 W-only applications with an ILD of 3 mm resulted in durable linear electrical block, whereas for 90 W applications, only the lines with ILDs of 4 and 3 mm were blocked. No complications were detected during ablation procedures, but all power and ILD combinations except 50 W–6 mm resulted in asymptomatic shallow lung lesions. CONCLUSION: In the intercaval region in sheep, for 50 W applications with an AI value of ∼370, the optimal ILD is 3 mm, whereas for 90 W–4 s applications, the optimal ILD is 3–4 mm.
format Online
Article
Text
id pubmed-10629717
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-106297172023-11-08 Optimal interlesion distance for 90 and 50 watt radiofrequency applications with low ablation index values: experimental findings in a chronic ovine model Bortone, Agustín Alfonso Ramirez, F Daniel Constantin, Marion Bortone, Clara Hébert, Caroline Constantin, Justine Bialas, Patric Limite, Luca Rosario Europace Translational Research AIMS: The optimal interlesion distance (ILD) for 90 and 50 W radiofrequency applications with low ablation index (AI) values in the atria has not been established. Excessive ILDs can predispose to interlesion gaps, whereas restrictive ILDs can predispose to procedural complications. The present study sought, therefore, to experimentally determine the optimal ILD for 90 W–4 s and 50 W applications with low AI values to optimize catheter ablation outcomes in humans. METHODS AND RESULTS: Posterior intercaval lines were created in eight adult sheep using CARTO and the QDOT-MICRO catheter in a temperature-controlled mode. In four animals, the lines were created with 50 W applications, a target AI value ≥350, and ILDs of 6, 5, 4, and 3 mm, respectively. In the other four animals, the lines were created with 90 W–4 s applications and ILDs of 6, 5, 4, and 3 mm, respectively. Activation maps were created immediately after ablation and at 21 days to assess linear block prior to gross and histological analyses. All eight lines appeared transmural and continuous on histology. However, for 50 W-only applications with an ILD of 3 mm resulted in durable linear electrical block, whereas for 90 W applications, only the lines with ILDs of 4 and 3 mm were blocked. No complications were detected during ablation procedures, but all power and ILD combinations except 50 W–6 mm resulted in asymptomatic shallow lung lesions. CONCLUSION: In the intercaval region in sheep, for 50 W applications with an AI value of ∼370, the optimal ILD is 3 mm, whereas for 90 W–4 s applications, the optimal ILD is 3–4 mm. Oxford University Press 2023-10-18 /pmc/articles/PMC10629717/ /pubmed/37851513 http://dx.doi.org/10.1093/europace/euad310 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Translational Research
Bortone, Agustín Alfonso
Ramirez, F Daniel
Constantin, Marion
Bortone, Clara
Hébert, Caroline
Constantin, Justine
Bialas, Patric
Limite, Luca Rosario
Optimal interlesion distance for 90 and 50 watt radiofrequency applications with low ablation index values: experimental findings in a chronic ovine model
title Optimal interlesion distance for 90 and 50 watt radiofrequency applications with low ablation index values: experimental findings in a chronic ovine model
title_full Optimal interlesion distance for 90 and 50 watt radiofrequency applications with low ablation index values: experimental findings in a chronic ovine model
title_fullStr Optimal interlesion distance for 90 and 50 watt radiofrequency applications with low ablation index values: experimental findings in a chronic ovine model
title_full_unstemmed Optimal interlesion distance for 90 and 50 watt radiofrequency applications with low ablation index values: experimental findings in a chronic ovine model
title_short Optimal interlesion distance for 90 and 50 watt radiofrequency applications with low ablation index values: experimental findings in a chronic ovine model
title_sort optimal interlesion distance for 90 and 50 watt radiofrequency applications with low ablation index values: experimental findings in a chronic ovine model
topic Translational Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10629717/
https://www.ncbi.nlm.nih.gov/pubmed/37851513
http://dx.doi.org/10.1093/europace/euad310
work_keys_str_mv AT bortoneagustinalfonso optimalinterlesiondistancefor90and50wattradiofrequencyapplicationswithlowablationindexvaluesexperimentalfindingsinachronicovinemodel
AT ramirezfdaniel optimalinterlesiondistancefor90and50wattradiofrequencyapplicationswithlowablationindexvaluesexperimentalfindingsinachronicovinemodel
AT constantinmarion optimalinterlesiondistancefor90and50wattradiofrequencyapplicationswithlowablationindexvaluesexperimentalfindingsinachronicovinemodel
AT bortoneclara optimalinterlesiondistancefor90and50wattradiofrequencyapplicationswithlowablationindexvaluesexperimentalfindingsinachronicovinemodel
AT hebertcaroline optimalinterlesiondistancefor90and50wattradiofrequencyapplicationswithlowablationindexvaluesexperimentalfindingsinachronicovinemodel
AT constantinjustine optimalinterlesiondistancefor90and50wattradiofrequencyapplicationswithlowablationindexvaluesexperimentalfindingsinachronicovinemodel
AT bialaspatric optimalinterlesiondistancefor90and50wattradiofrequencyapplicationswithlowablationindexvaluesexperimentalfindingsinachronicovinemodel
AT limitelucarosario optimalinterlesiondistancefor90and50wattradiofrequencyapplicationswithlowablationindexvaluesexperimentalfindingsinachronicovinemodel