Cargando…

Research on digital twin modeling and monitoring technology for smoke alarm calibration system

Aiming at the problems of backward calibration method of smoke alarm, low production efficiency and difficult real-time monitoring, a digital twin system modeling and monitoring method of smoke alarm calibration is proposed. First, through the analysis of smoke alarm calibration requirements, the ov...

Descripción completa

Detalles Bibliográficos
Autores principales: Min, Wu, Wenfeng, Ying
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10630454/
https://www.ncbi.nlm.nih.gov/pubmed/37935818
http://dx.doi.org/10.1038/s41598-023-46761-1
_version_ 1785132153354321920
author Min, Wu
Wenfeng, Ying
author_facet Min, Wu
Wenfeng, Ying
author_sort Min, Wu
collection PubMed
description Aiming at the problems of backward calibration method of smoke alarm, low production efficiency and difficult real-time monitoring, a digital twin system modeling and monitoring method of smoke alarm calibration is proposed. First, through the analysis of smoke alarm calibration requirements, the overall framework design of the digital twin calibration system for smoke alarm is proposed, and then the twin model of smoke box is constructed by running the digital twin five-dimensional model. The physical smoke box, geometric model, physical model, rule model and behavior model are introduced in detail; Then the communication system architecture, data acquisition and data mapping are used to construct the twin data model; Finally, the feasibility was verified by the calibration system of an enterprise. Through the system, the qualified rate of smoke alarm calibration was increased from 98 to 99.6%, and the repair rate of defective products was reduced by 1.6%.
format Online
Article
Text
id pubmed-10630454
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-106304542023-11-07 Research on digital twin modeling and monitoring technology for smoke alarm calibration system Min, Wu Wenfeng, Ying Sci Rep Article Aiming at the problems of backward calibration method of smoke alarm, low production efficiency and difficult real-time monitoring, a digital twin system modeling and monitoring method of smoke alarm calibration is proposed. First, through the analysis of smoke alarm calibration requirements, the overall framework design of the digital twin calibration system for smoke alarm is proposed, and then the twin model of smoke box is constructed by running the digital twin five-dimensional model. The physical smoke box, geometric model, physical model, rule model and behavior model are introduced in detail; Then the communication system architecture, data acquisition and data mapping are used to construct the twin data model; Finally, the feasibility was verified by the calibration system of an enterprise. Through the system, the qualified rate of smoke alarm calibration was increased from 98 to 99.6%, and the repair rate of defective products was reduced by 1.6%. Nature Publishing Group UK 2023-11-07 /pmc/articles/PMC10630454/ /pubmed/37935818 http://dx.doi.org/10.1038/s41598-023-46761-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Min, Wu
Wenfeng, Ying
Research on digital twin modeling and monitoring technology for smoke alarm calibration system
title Research on digital twin modeling and monitoring technology for smoke alarm calibration system
title_full Research on digital twin modeling and monitoring technology for smoke alarm calibration system
title_fullStr Research on digital twin modeling and monitoring technology for smoke alarm calibration system
title_full_unstemmed Research on digital twin modeling and monitoring technology for smoke alarm calibration system
title_short Research on digital twin modeling and monitoring technology for smoke alarm calibration system
title_sort research on digital twin modeling and monitoring technology for smoke alarm calibration system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10630454/
https://www.ncbi.nlm.nih.gov/pubmed/37935818
http://dx.doi.org/10.1038/s41598-023-46761-1
work_keys_str_mv AT minwu researchondigitaltwinmodelingandmonitoringtechnologyforsmokealarmcalibrationsystem
AT wenfengying researchondigitaltwinmodelingandmonitoringtechnologyforsmokealarmcalibrationsystem