Cargando…

In situ detection of reactive oxygen species spontaneously generated on lead acid battery anodes: a pathway for degradation and self-discharge at open circuit

Prospects for refurbishing and recycling energy storage technologies such as lead acid batteries (LABs) prompt a better understanding of their failure mechanisms. LABs suffer from a high self-discharge rate accompanied by deleterious hard sulfation processes which dramatically decrease cyclability....

Descripción completa

Detalles Bibliográficos
Autores principales: Asserghine, Abdelilah, Baby, Aravind, Putnam, Seth T., Qian, Peisen, Gao, Elizabeth, Zhao, Huimin, Rodríguez-López, Joaquín
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10631249/
https://www.ncbi.nlm.nih.gov/pubmed/37969580
http://dx.doi.org/10.1039/d3sc04736a
_version_ 1785146074803994624
author Asserghine, Abdelilah
Baby, Aravind
Putnam, Seth T.
Qian, Peisen
Gao, Elizabeth
Zhao, Huimin
Rodríguez-López, Joaquín
author_facet Asserghine, Abdelilah
Baby, Aravind
Putnam, Seth T.
Qian, Peisen
Gao, Elizabeth
Zhao, Huimin
Rodríguez-López, Joaquín
author_sort Asserghine, Abdelilah
collection PubMed
description Prospects for refurbishing and recycling energy storage technologies such as lead acid batteries (LABs) prompt a better understanding of their failure mechanisms. LABs suffer from a high self-discharge rate accompanied by deleterious hard sulfation processes which dramatically decrease cyclability. Furthermore, the evolution of H(2), CO, and CO(2) also poses safety risks. Despite the maturity of LAB technologies, the mechanisms behind these degradation phenomena have not been well established, thus hindering attempts to extend the cycle life of LABs in a sustainable manner. Here, we investigate the effect of the oxygen reduction reaction (ORR) on the sulfation of LAB anodes under open circuit (OC). For the first time, we found that the sulfation reaction is significantly enhanced in the presence of oxygen. Interestingly, we also report the formation of reactive oxygen species (ROS) during this process, known to hamper cycle life of batteries via corrosion. Electron spin resonance (ESR) and in situ scanning electrochemical microscopy (SECM) unambiguously demonstrated the presence of OH˙ and of H(2)O(2) as the products of spontaneous ORR on LAB anodes. High temporal resolution SECM measurements of the hydrogen evolution reaction (HER) during LAB anode corrosion displayed a stochastic nature, highlighting the value of the in situ experiment. Balancing the ORR and HER prompts self-discharge while reaction of the carbon additives with highly oxidizing ROS may explain previously reported parasitic reactions generating CO and CO(2). This degradation mode implicating ROS and battery corrosion impacts the design, operation, and recycling of LABs as well as upcoming chemistries involving the ORR.
format Online
Article
Text
id pubmed-10631249
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-106312492023-11-15 In situ detection of reactive oxygen species spontaneously generated on lead acid battery anodes: a pathway for degradation and self-discharge at open circuit Asserghine, Abdelilah Baby, Aravind Putnam, Seth T. Qian, Peisen Gao, Elizabeth Zhao, Huimin Rodríguez-López, Joaquín Chem Sci Chemistry Prospects for refurbishing and recycling energy storage technologies such as lead acid batteries (LABs) prompt a better understanding of their failure mechanisms. LABs suffer from a high self-discharge rate accompanied by deleterious hard sulfation processes which dramatically decrease cyclability. Furthermore, the evolution of H(2), CO, and CO(2) also poses safety risks. Despite the maturity of LAB technologies, the mechanisms behind these degradation phenomena have not been well established, thus hindering attempts to extend the cycle life of LABs in a sustainable manner. Here, we investigate the effect of the oxygen reduction reaction (ORR) on the sulfation of LAB anodes under open circuit (OC). For the first time, we found that the sulfation reaction is significantly enhanced in the presence of oxygen. Interestingly, we also report the formation of reactive oxygen species (ROS) during this process, known to hamper cycle life of batteries via corrosion. Electron spin resonance (ESR) and in situ scanning electrochemical microscopy (SECM) unambiguously demonstrated the presence of OH˙ and of H(2)O(2) as the products of spontaneous ORR on LAB anodes. High temporal resolution SECM measurements of the hydrogen evolution reaction (HER) during LAB anode corrosion displayed a stochastic nature, highlighting the value of the in situ experiment. Balancing the ORR and HER prompts self-discharge while reaction of the carbon additives with highly oxidizing ROS may explain previously reported parasitic reactions generating CO and CO(2). This degradation mode implicating ROS and battery corrosion impacts the design, operation, and recycling of LABs as well as upcoming chemistries involving the ORR. The Royal Society of Chemistry 2023-10-18 /pmc/articles/PMC10631249/ /pubmed/37969580 http://dx.doi.org/10.1039/d3sc04736a Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Asserghine, Abdelilah
Baby, Aravind
Putnam, Seth T.
Qian, Peisen
Gao, Elizabeth
Zhao, Huimin
Rodríguez-López, Joaquín
In situ detection of reactive oxygen species spontaneously generated on lead acid battery anodes: a pathway for degradation and self-discharge at open circuit
title In situ detection of reactive oxygen species spontaneously generated on lead acid battery anodes: a pathway for degradation and self-discharge at open circuit
title_full In situ detection of reactive oxygen species spontaneously generated on lead acid battery anodes: a pathway for degradation and self-discharge at open circuit
title_fullStr In situ detection of reactive oxygen species spontaneously generated on lead acid battery anodes: a pathway for degradation and self-discharge at open circuit
title_full_unstemmed In situ detection of reactive oxygen species spontaneously generated on lead acid battery anodes: a pathway for degradation and self-discharge at open circuit
title_short In situ detection of reactive oxygen species spontaneously generated on lead acid battery anodes: a pathway for degradation and self-discharge at open circuit
title_sort in situ detection of reactive oxygen species spontaneously generated on lead acid battery anodes: a pathway for degradation and self-discharge at open circuit
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10631249/
https://www.ncbi.nlm.nih.gov/pubmed/37969580
http://dx.doi.org/10.1039/d3sc04736a
work_keys_str_mv AT asserghineabdelilah insitudetectionofreactiveoxygenspeciesspontaneouslygeneratedonleadacidbatteryanodesapathwayfordegradationandselfdischargeatopencircuit
AT babyaravind insitudetectionofreactiveoxygenspeciesspontaneouslygeneratedonleadacidbatteryanodesapathwayfordegradationandselfdischargeatopencircuit
AT putnamsetht insitudetectionofreactiveoxygenspeciesspontaneouslygeneratedonleadacidbatteryanodesapathwayfordegradationandselfdischargeatopencircuit
AT qianpeisen insitudetectionofreactiveoxygenspeciesspontaneouslygeneratedonleadacidbatteryanodesapathwayfordegradationandselfdischargeatopencircuit
AT gaoelizabeth insitudetectionofreactiveoxygenspeciesspontaneouslygeneratedonleadacidbatteryanodesapathwayfordegradationandselfdischargeatopencircuit
AT zhaohuimin insitudetectionofreactiveoxygenspeciesspontaneouslygeneratedonleadacidbatteryanodesapathwayfordegradationandselfdischargeatopencircuit
AT rodriguezlopezjoaquin insitudetectionofreactiveoxygenspeciesspontaneouslygeneratedonleadacidbatteryanodesapathwayfordegradationandselfdischargeatopencircuit